Summary of Contents for Saijo Denki WI-CH2010-WSDC2-W-APS-INV

  • Page 1 HYBRID INVERTER HYBRID INVERTER...
  • Page 2 CONTENTS 18,000-25,000 Btu/h 1.-3. Dimension 4.-14 Installation detail Wiring diagram Indoor unit 16.-17 Wiring diagram Outdoor unit Connecting the Cable To The Indoor Unit WHITE ORANGE Warning:1. Using circuit breaker which has contact gab at least 3 mm for installation 2.
  • Page 3 Indoor Unit 9,000-12,000 Btu/h 9,000-12,000 Btu/h Outdoor Unit 9,000-12,000 Btu/h...
  • Page 4: Wiring Diagram Indoor Unit

    Dimension Wiring diagram Indoor unit 9,000-36,000 Btu/h Indoor Unit 18,000-25,000 Btu/h Outdoor Unit 18,000 Btu/h...
  • Page 5 Use a hexagonal wrench to open the suction valve and discharge valve through the end. (the Indoor Unit 30,000-36,000 Btu/h suction valve should be opened before the discharge valve) Manifold gage Yellow cord Arrow valve Vacuum pump Blue cord Leakage checking Check for leakage at every joint by using soapsuds.
  • Page 6 1. Should separate one circuit breaker for one air conditioner only. 2. Selecting the area for installation 2. Avoid tapping the power cord. 3. If necessary, extend the supplied plug cable. Using the recommended cable follow as table. To best decision for selecting the area for installation that should be suited with customer’s 4.
  • Page 7 If the condensing unit is installed in a location that has an open airflow, the condensing unit should be installed in a direction such that airflow out from the condensing unit is perpendicular to the open air flow direction. Open Air Air flow out Open Air End of drain pipe...
  • Page 8 Check th at the flaring is correct, referring to the illustrations below for examples of incorrect flaring. 2.1 Remote Control Uni t 1. Make sure that you install the remote control unit in an area free from obstacles such as curtains etc, which may block signals from the remote control unit.
  • Page 9: Installation Detail

    Installation detail 4. Indoor Unit & Outdoor Unit I nstallation 1. Make sure that you have the required tools available. 4.1 Fixing the Hanging Plate Before fixing the hanging plate to the wall, the things must determine arefollowing: The hanging plate will be supplied which depend on model of indoor unit. 9,000-12,000 Btu/h If you wish to shorten the piping, cut it using a pipe cutter, taking care to ensure that the cut edge remains at a 90°...
  • Page 10: Air Outlet

    Purging the Unit Cutting/Extending the tube On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. In recommended, the refrigerant tubes are not over than 5 m eters. If necessary, the length can be up to 30 meters, but the refrigerant must be added to the circuit according table below: 1.