Page 2
If you do not understand these directions, or have doubts about the safety of the installation, contact GPO Display tech support or call a qualified contractor. GPO Display is not liable for damage or injury caused by incorrect mounting, assembly, or use.
Leave a slight (≥0.5mm) gap between displays in order to protect your LCD screens from the damage through the direct transfer of weight. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 4
Stand the display vertically to make sure the its weight spread evenly throughout the bottom bezel. Do not rest on corners or lean forward/back. (Fig.4) Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 5
Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 6
Ventilation space must not be covered or closed off at the front of the opening. If for some reason the opening needs to be covered, other means of ventilation will need to be incorporated into the design. Contact GPO Display for design review and recommendations. 2”...
Page 7
Structure for the installation The structural design and construction for the display installation is the customer’s or its installer’s responsibility. GPO Display does not take any responsibility on design or construction of installations. The minimum requirements for space, strength of the structure, electronic, heat dissipation and environmental condition is described in this manual.
Page 8
Serial Command Protocol and video wall control (for Side Covers) program (varies by video wall series) ACR Manual (if applicable) Wall Mount Drawing SCREW (BH T 4*20L) Z-Bolt Y-Knob Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 9
Recommend Receiver / Decoder / Media Players Positions: A or C . [HLM46T & HLM46TE Device placement] [HLM49T & HLM49TE Device placement] A & C zones: 2.35 (W) x 15 (H) x 2.2”(Depth) for A & C zone: 3.5 x 15 x 2.2” (Depth) for Third party Third party placement.
Page 10
[Tip. Third party player placement] Device inputs/output terminals should be positioned facing to the left, as shown in the image to the right. Devices (Receiver/decoder, Distribution Amplifier, etc.) Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
B: Secure wooden 2x4 or 2x6, or metal framing (4 X 1 T) to the wall as shown in the drawing to the right. 1. Construct the reinforcement frame to match specifications set forth by GPO Display 2. Continue constructing the reinforcement frame, adding cross bar supports where necessary 3.
Page 12
3. Assemble the mounts (affix to one another using interconnecting M8 bolts) and ensure that they are level, as instructed previously in this manual. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 13
The highest Display Sequence number is 99. Contact GPO Display for arrays comprised of more than 99 displays. A 3x3 array will be used as an example in the following pages. Contact GPO Display if you are unsure about how to apply these instructions and concepts to other video wall array configurations.
Page 14
*Note: Floor surface must be level/even when connecting mounts. Must connect mounts using M8 Bolts and nuts at all interconnection positions (Long side: 14 positions, Short Side: 5 Positions) Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 15
For 3x3 arrays, you may assemble rows of mounts on the floor* prior to attaching them to the wall. See example of second row to the right *Note: Floor surface must be level/even when connecting mounts. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 16
See example of third (top) and final row to the right *Note: Floor surface must be level/even when connecting mounts. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 17
1mm above the Y-Adjustment plate prior to installation of the displays. Further adjustments can take place once displays are installed. Z-Bolt Y-Adjustment Plate Z-Bolt Y-Knob Y-Knob Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 18
=> Locate the cable tie mounts in the center of the mount structure (rather than the bottom or top Locate/mount all devices before display is mounted Example shown above is 55” Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Note: Set ID’s are assigned prior to shipment. [NSV / EN Series] [EK Series] Set ID’s are marked on the display box. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 20
Used for convenient dismounting when displays are in lower channel Resting Position This is where the display is seated when installation is complete Lower Upper Service Service Channel Channel Opening Installation Channel Resting Position Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 21
The bottom bezel of the display should align with the horizontal notches during mounting. Guide notch *NOTE: Prior to installing displays, ensure cabling is properly positioned, as shown on p. 18 of this manual. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 22
Move all three displays to the right. Set ID Set ID Mount & display order: Bottom to top Set ID Alignment adjustment order: Top to bottom Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 23
Set ID Set ID Set ID Set ID Set ID Set ID Repeat the same steps taken for the previous columns with the left column of displays. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 24
Axis adjustments, push very gently with an open, gloved palm Z-BOLT on the top of the display and then engage the bottom Z-Bolts by turning counter-clockwise. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 25
Y-Axis alignment. Case#2 Turn the inner Y-knobs (2 and 3) clockwise to move the Y-Knob displays upward as needed to achieve Y-Axis alignment. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 26
The application of side covers will lock displays in line with the mounts on the X-axis, preventing any drift. Display 3.4” 3.4” Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 27
Set ID Set ID position) Set ID Set ID Set ID Look over the wall for alignment issues from various angles. Set ID Set ID Set ID Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 28
#2, #6 for #3, and so on for following row. *Conducting Z-Axis adjustments prior to Y-Axis adjustments is recommended. Note: displays have been renumbered to show recommended order of alignment adjustments Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 29
Attach side cover by inserting screws into the outer sides of H-Mounts on the perimeter of the array. SCREW (FH M 4*8L) (for Side Covers) Side Cover Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 30
• Carefully lift #9 up ~1.4” so that the pegs align with the opening (bottom of Set #9 will align with corner guidelines on mount). • Gently pull #9 outward. • From here, dismounting the remaining displays becomes easier. You may now dismount Sets 6 or 8. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 31
Chapter 7 Cabling Setup Precaution for Cables Connection of GPO Display’s Video Wall Digital noise may appear due to poor quality DVI cabling. If the video signal needs be delivered from a distance, electric noise must be accounted for. If the distance is great or there is a serious noise issue, an optical fiber extender system is recommend over CAT-5/6 extension.
Page 32
The RS-232 daisy chain limitation is listed as 20 displays, although theoretically more units can be accommodated. 25 displays was the maximum number of units tested during production. While GPO Display can make no guarantees, RS-232 daisy-chaining should be able to take place on up to 25 displays.
Page 33
HDMI Out HDMI IN HDMI IN Set ID #8 Set ID #7 Set ID #9 HDMI Out HDMI Out HDMI Out HDMI IN HDMI IN HDMI IN Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 34
Use Signal Distributor outputs to connect to displays in each vertical column as shown on right When using D/A, connect individual displays via DVI daisy-chain in order from bottom to top using DVI cables as shown top/right Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Page 35
All other remote control functions are conducted in the same manner as Power On/Off For more information, consult the ACR user manual. Video Walls - Commercial Monitors - Digital Signage - Visual Solutions www.gpodisplay.com GPO Display...
Need help?
Do you have a question about the HLM49T and is the answer not in the manual?
Questions and answers