ASSA ABLOY does not assume any responsibility for incidental or consequential damages arising from the use of this manual. All information and drawings in this document are the property of ASSA ABLOY. Unauthorized use and reproduction is prohibited. VingCard and Elsafe are registered trademarks of ASSA ABLOY.
- Consult the dealer or an experienced radio/TV technician for help. The concerned end product must be labeled to say 'Contains FCC ID: Y7V-683081118C1'. The concerned end product must be labeled to say 'FCC ID: Y7V-TZENHV'. ASSA ABLOY Hospitality 66 8003 015-3...
In that case, the final end product must be labeled in a visible area with the following: 'Contains IC: 9514A 683081118C1' 'IC: 9514A-TZENHV' ASSA ABLOY Hospitality 66 8003 015-3...
Note: This thermostat is an independently mounted control for surface mounting. A main task for Orion EMS is to determine whether or not a guest room is physically occupied. When a room is not occupied, Orion EMS controls the HVAC (Heating Ventilation and Air Conditioning) systems based on the configurable settings of the system.
The thermostat has a built-in ZigBee router via which it communicates to the software and the devices within the room. The thermostat stores all parameters needed for Orion EMS; if the thermostat controller is used as well, the parameters (with a few exceptions;...
Note: This The pre- condition time can be 1-12 hours or 'disabled'; parameter default is 2 hours. requires that the Online option has been set in Visionline. ASSA ABLOY Hospitality 66 8003 015-3...
Page 10
1-255 seconds Refresh cycle The Orion EMS system can, in setback control, run the A/C unit every 25 minutes for a period of 2 minutes to re-circulate the air in the room; the optional function is only for cooling mode.
3 for more information. In addition, they are shown in the alarm list. Unless Orion EMS is installed as a separate client, the alarm list will also show other types of alarms not related to Orion EMS, e.g. housekeeping failed.
This is achieved by presenting an Enable EMI events card at each lock. The card is one of the ZigBee configuration cards that can be issued in Visionline; see Installation manual Orion High Voltage Thermostat for details. The following events are sent to the thermostat from the motion sensor:...
The thermostat event report shows all events that have been sent online from the thermostats or been transferred to the server via Orion Service; see Quick reference guide Orion Service for details. The housekeeping function keeps the list size limited by removing events that are older than a user defined number of days;...
The guest sets the desired temperature and the HVAC system will control the room based on this setting. The Orion thermostat will enter the occupied state only when the door is closed and in-room events are detected (motion, deadbolt engaged, thermostat key pressed).
If the timer elapses with no further detection of in-room events, the thermostat will revert to maintaining the room temperature at the unsold setback. If an exterior door is left open, the thermostat will turn the air handler off. ASSA ABLOY Hospitality 66 8003 015-3...
Per guest setting if opened by guest. Unoccupied or Unsold Setback if opened by staff. If no lock interface, per guest setting. Closed No Setback Unoccupied or Unsold Open Setback Unoccupied or Unsold Table 2 ASSA ABLOY Hospitality 66 8003 015-3...
Closed Open Unoccupied or unsold Open Open Unoccupied or Unsold Closed Closed Setback Unoccupied or Unsold Open Closed Setback Unoccupied or Unsold Closed Open Unoccupied or Unsold Open Open Unoccupied or Unsold Table 4 ASSA ABLOY Hospitality 66 8003 015-3...
If the temperature continues to drop, first the output for ‘Fan 2/Medium’ is triggered and then the output for ‘Fan 3/High’. The Orion EMS devices strive towards different temperatures depending on if the room is occupied, unoccupied or unsold. For ‘occupied mode’ the goal is the setpoint, i.e. the temperature which the guest has set on the thermostat.
1.7 Orion EMS parameters There are a number of Orion EMS parameters whose values can be modified in the software. Different operator templates can be given different authorities to modify the parameters. Some parameters are considered as basic and some as advanced.
Page 20
Use RV output according to the occupancy status. (Thermostat profile Use G2 output The intelligent switch is an output details dialog, Misc tab) for lighting control which works according to the occupancy status. ASSA ABLOY Hospitality 66 8003 015-3...
Page 21
Max HVAC runtime this long without turning off. (Tools/Options dialog, expand Energy management and choose General) The Orion EMS features may be 0-99 hours 0 hours Max setback override overridden when needed, e.g. for VIP guests where no setbacks (Tools/Options dialog, should apply;...
Page 22
The Orion EMS system can in Enable/disable Disable Refresh cycle setback control run the A/C unit every 25 minutes for a period of (Thermostat profile 2 minutes to re-circulate the air details dialog, Misc tab) in the room; this optional function is only for cooling mode.
1.8 Operator templates The operator templates decide the level of authority for different Orion EMS operations. To change the authority for handling thermostat parameters: 1. Double click on Operator templates under the Lists tab in the navigation window. 2. In the Operator templates...
4. If applicable, repeat step 3 with other alternatives in the left part of the dialog. 5. When all applicable changes according to steps 2-4 above have been performed, click OK. ASSA ABLOY Hospitality 66 8003 015-3...
Note: Override mode can also be set from Orion Service; see Quick reference guide Orion Service for details. If the override mode has been set from Orion Service, it must also be cleared from Orion Service. If the override mode has been set from the Change thermostat settings dialog as below in this section, it can however be cleared either from Orion Service or from the Change thermostat settings dialog.
Page 26
General details. If ‘Max setback override’ is 0 (default), there is however no limitation in time and the Orion EMS features can be overridden until further notice. 5. Click the Set button next to the Override mode drop-down menu.
This does not change the way the guest uses the system, but the thermostat is programmed accordingly and will not call for a function that is not available. Table 6 ASSA ABLOY Hospitality 66 8003 015-3...
AUTO when the automatic fan mode is enabled. The Wrench indicator is displayed when maintenance is required on any of the Orion EMS devices in the room or on the HVAC unit. This icon is only displayed Wrench to hotel staff.
By clicking the arrow to the left of the heading ’Runtime % - Savings and occupancy’, it is possible to choose that the diagram should instead show ‘Lighting and Room control (kWh)’. Figure 18 ASSA ABLOY Hospitality 66 8003 015-3...
Page 30
48 hours Note: When any of the alarms for maintenance 1-3 has been taken care of, the concerned maintenance counter must be reset from Orion Service; see section about configuring thermostat in Quick reference guide Orion Service. ASSA ABLOY Hospitality...
Note: The Alarms dialog will also show alarms that are not related to Orion EMS; except for in the separate Orion EMS client, where only Orion EMS alarms are shown.
By hovering with the cursor over a room in any Real time room status graph, the tooltip will show: occupancy status; unsold/unoccupied/occupied HVAC status; not running/cooling/heating room temperature triggered Orion EMS alarms, if any Figure 19 Figure 20 Figure 21 If Occupancy status is...
Page 33
To check the status of a thermostat: 1. Double click on Thermostats under the Lists tab in the navigation window. 2. Mark the applicable thermostat and click Status. Figure 23 ASSA ABLOY Hospitality 66 8003 015-3...
Page 34
1, 2 and 3 respectively are shown. Note: The total numbers of hours before the three different maintenance alarms should be Figure 25 triggered are specified at Tools/Options/Energy management/Maintenance. ASSA ABLOY Hospitality 66 8003 015-3...
Page 35
10.At Occupancy, the occupancy status is shown. 11.At HVAC, it is shown whether the HVAC is ‘not running’, ‘cooling’ or ‘heating’. 12.At Override mode, it is shown whether the thermostat parameters are overridden. ASSA ABLOY Hospitality 66 8003 015-3...
Page 36
SMS or both. 4. If more users should be notified about the same room, repeat steps 2-3 for the room. See Installation instruction Communication option for more information about the option. ASSA ABLOY Hospitality 66 8003 015-3...
The Occupancy report shows the number of rooms that are rented per day; as a number and also as a percentage of the total number of rooms. 1. Double click on Ocupancy under the Reports tab in the navigation window. Figure 28 ASSA ABLOY Hospitality 66 8003 015-3...
The Calculated HVAC column shows how much the HVAC units would run if the Orion EMS option had not been used, i.e. if Orion EMS had not saved energy when the rooms are unoccupied. The Calculated HVAC is continuously calculated every hour as the total runtime for all HVAC units in occupied rooms divided by the total time these rooms have been occupied.
Figure 30 1. Enable energy management: This checkbox is automatically marked when the Orion EMS option is set in the Visionline software. If the Orion EMS option should temporarily be turned off, unmark 'Enable energy management' and click OK. 2. Staff entry allow room occupancy change: If this checkbox is marked, the room will go to occupied state when motion is triggered if staff is in the room, i.e.
Maintenance counter 2 is for ‘cooling’ Maintenance counter 3 is for ‘cooling or heating’ Figure 31 1. Enter the applicable maintenance value(s) in hours. 2. If applicable, rename the three maintenance counters to your needs. 3. Click OK. ASSA ABLOY Hospitality 66 8003 015-3...
1-9999) Note: Events use a considerable amount of disk space, so the number of days to keep events should be kept low. Note: In the separate Orion EMS client, the housekeeping items are found at Tools/ Options/System/Housekeeping. Figure 32 1.
9. Orion EMS in SysMon The maintenance software SysMon (System Monitor) is found in the Visionline installation folder and also in the installation folder for the separate Orion EMS, if the latter is applicable. It contains several dialogs, of which the ones below...
The temperature which the guest has set on the thermostat Occupancy Unsold/Unoccupied/Occupied HVAC Off/Cooling/Heating Alarm Yes/No Ovr setback This column shows if the thermostat in the concerned room has been overridden; Yes/No Table 8 ASSA ABLOY Hospitality 66 8003 015-3...
9.2 Online commands The Online Command Log dialog of SysMon shows commands that have been sent to the thermostats. The online commands are listed in reverse chronological order. 1. Go to View/Online Commands. Figure 34 ASSA ABLOY Hospitality 66 8003 015-3...
Set-Time command cancels any previous Set-Time command. Buffered Yes if the command has timed out. It has then been buffered as a single-cast command for all locks that have not answered. Table 9 ASSA ABLOY Hospitality 66 8003 015-3...
1. Click the Filter button in the Room Event List dialog; the dialog to the right will be shown. 2. Enter the applicable filtering information and click OK. The result is presented in a room event list. Figure 37 ASSA ABLOY Hospitality 66 8003 015-3...
2. Use the flathead screw driver to bend the thermostat; bend the locking arms and in the locking arm at the bottom of the thermostat; same time pull carefully. at the same time pull carefully. Figure 38 Figure 39 ASSA ABLOY Hospitality 66 8003 015-3...
The thermostat Reversing valve output 2.0AF appears to be dead. Cool output Heat output Internal power supply of the thermostat Lower fuse 5x20mm The fan outputs The fan outputs 6.3AT stop working. Table 10 ASSA ABLOY Hospitality 66 8003 015-3...
Appendix A: Quick reference of technical data Note: If external motion sensor is applicable, see Installation manual Orion High Voltage Thermostat for technical data and information about installation. Dimensions (WxHxD) 112 x 117 x 35 mm (4 13/32" x 4 19/32" x 1 3/8") Mains voltage input Universal voltage input 100VAC-277VAC;...
Page 50
- it is then 5 minutes and cannot be changed. The dwell-off time prevents short-cycling of the compressor. Required Visionline version 1.15.0 or higher for full functionality of thermostat profiles Required Orion Service version 1.3.0 or higher Table A1 ASSA ABLOY Hospitality 66 8003 015-3...
If no voltage is applied to the correct inputs, a voltage drop has occurred between the thermostat and the FCU/PTAC. Check the wiring. Note: See Installation manual Orion High Voltage Thermostat for information about the heat/cool relays used. Fan speed not working 1.
3. If the RF door switch is applicable, confirm that door open and door closed events are logged at the thermostat. Also use the Diagnostics feature in Orion Service to confirm that the door position is shown correctly; Open and Closed.
If all is OK, the property needs to have their HVAC technician check the unit. b. If the thermostat outputs are incorrect: i. First check the configuration of the thermostat by using Orion Service to read out the parameters of the thermostat; do not just rely on looking at the parameters in the Visionline or Orion EMS software.
Appendix C: Read more Document name: Document number: Installation instruction Communication option 66 5013 026 Installation manual Orion High Voltage Thermostat 66 8003 016 Revision history Date Change November 7, 2014 First release January 11, 2016 Updated layout October 12, 2016...