INSTRUCTION MANUAL
FEATURES:
1) Atomic clock for DCF:
• Calendar (month/date/weekday)
• Time (hour/minute)
• Inside temperature (° C / ° F selectable)
2) 7 weeks of language: English, German, Italian, French, Dutch,
Spanish, Danish
3) 6 Buttons: MODE, UP, DOWN, CHANNEL, ALERT, SNZ / LIGHT
4) Daylight saving time function
5) Weather forecast: sunny, slightly, cloudy, rain
6) Alarm and snooze Function
7) Indoor Temperature/Humidity
8) Wireless Outdoor Temperature / Humidity with ° C / ° F selectable
9) Low Battery indicator: Main unit, Transmitter (Display when out of
battery)
10) Trends
11) High/Low Daily records
12) Comfort indicator
LCD Display:
Full display diagram (Fig. 1A)
Indoor temperature:
• Measure range = 0 ° C to 50 ° C (32 ° F to 122 ° F)
• Accuracy ± 1 degree Fahrenheit at room temperature (20 ° C to 24 ° C)
(68 ° F to 75 ° F)
• Accuracy ±2 degrees Fahrenheit 0 ° C to 50 ° C (32 ° F to 122 ° F)
• Resolution=1 ° F or 1 ° C
• When above 122 ° F (50 ° C) the temperature should display "HH.H
• When below 32 ° F (0 ° C) the temperature should display "LL.L „
• Temperature Cycle: 30 seconds
Indoor Humidity:
• Operating Temperature Range = 32 ° F to 120 ° F (0 ° C to 50 ° C)
• Operating humidity range = 20 % RH to 95 %
• Accuracy +/- 5% RH (at 25 ° C , 30 % RH to 80 % RH)
• Accuracy +/- 8% RH (at 25 ° C , 20 % RH to 29 % RH; 80 % RH to
95 % RH)
• Resolution = 1 % RH
Outdoor temperature:
• Operating temperature range = -22 ° F to 140 ° F (-30 ° C to 60 ° C)
• Accuracy ± 1 degree at room temperature (68 ° F to 75 ° F) (20 ° C to 24 ° C)
• Accuracy ± 2 degrees Fahrenheit 32 ° F to 122 ° F (0 ° C to 50 ° C)
• Resolution = 1 degree F
Notes:
Temperature values are to be determined in Fahrenheit and then
converted to Celsius if need for displaying Celsius.
• When above 140 ° F (60 ° C) the temperature should display "HH.H"
• When below -22 ° F (-30 ° C) the temperature should display
„LL.L" If no temperature signal is received over an hour, then
outdoor temperature should display dancing segments Dancing --.-
Outdoor Humidity:
• Operating humidity range = 20 % RH to 95 %
• Accuracy +/- 5 % RH (at 25 ° C, 30 % RH to 80 % RH)
• Accuracy +/- 8 % RH (at 25 ° C , 20 % RH to 29 % RH; 80 % RH to
95 % RH)
• Resolution = 1 % RH
Power up default:
Time: AM 00:00
Date/Day: Jan 1st, 2014, DIE
Time zone: PST
DST state: ON
Language: English
Operations
Power On:
1. Display full segment for 2 second.
2. The RF turn on and searching other wireless sensor via RF433 (Fig. 2)
3. After Outdoor sensor synchronized (Fig. 3)
Weekday display:
Figure seven languages (Fig. 4)
Setting operations:
1) Press and hold the "mode" button for two seconds to enter set mode,
the year will blink, press the „up" or „down" to set the desired state.
Normal display diagram (Fig. 1B)
2)
month position will blink, press the „up" or „down" to set the desired
month. Push and hold „up" or „down" button for fast adjust.
3)
position will blink, press the „up" or „down" to set the desired date.
Push and hold „up" or „down" button for fast adjust. Fig. 5
4)
the default is English, the language position will blink, press the
„up" or „down" to set the desired language
5)
world time zone position will blink, press the „up" or „down" to set the
desired time zone Push and hold „up" or „down" button for fast adjust.
6)
hr, the 12 / 24 hr position will blink, press the „up" or „down" to set the
desired 12 / 24 hr.
7)
hour position will blink, press the „up" or „down" to set the desired
hour. Push and hold „up" or „down" button for fast adjust.
8)
position will blink, press the „up" or „down" to set the desired minute.
Push and hold „up" or „down" button for fast adjust. Fig. 6
ENG
9)
"up" or "down" button for fast adjust.
10.
***When setting mode, If no buttons are pushed, it will automatically
time out and return to normal mode after 20 seconds.***
Alarm setting:
• ALARM HOUR: Press and hold MODE button to enter alarm time
setting mode. The Alarm Hour will flash. Use the UP or DOWN button
to set the Hour. Press and release the ALARM button.
• ALARM MINUTE: The Alarm Minutes will flash. Use the UP or DOWN
button to set the Minutes. Press and release the ALARM button to exit.
ALARM ICON
ALARM ACTIVATION:
• Press and release the MODE button repeatedly to activate or deactivate
the Alarm. The alarm icon appears when alarm is activated.
SNOOZE FUNCTION:
• When alarm sounds, press the SNOOZE button to trigger snooze for
5 minutes. The alarm icon flashes when the snooze feature is active.
• To stop alarm for one day, press AL button, while in snooze mode.
The alarm icon will show solid.
ALARM NOTE: Alarm is crescendo sound. When the alarm sounds,
it continues for 2 minute and then shuts off completely. Fig. 8
Atomic clock receiving:
1) Once power up, the atomic clock will automatically search for the
atomic signal.
2) While the atomic clock is seeking for the signal, the icon will pulsate
indicating the search mode. Fig 9
3) The atomic clock will automatically search for the atomic signal on
am 1:00, am 2:00 and am 3:00 every day. If the reception is not
successful, the clock will attempt am 4:00 and am 5:00. If still the
reception is not successful, the clock will not search for the signal on
the current day.
4) In normal mode, push the „DOWN" button for 3 seconds to enter
manual searching for the signal.
5) In reception mode, push the „UP" button for 3 seconds to exit
searching for the atomic signal.
*** Other key function will disable during receiving (except
backlight function by pressing SNOOZE button)***
Setting Fahrenheit or Celsius
In set mode, Press the "mode" button to select the Fahrenheit or
Celsius. Fig. 10
Temperature and Alert alarms
Setting the temperature alarm
• Press „CHANNEL" to select the outdoor sensor. Press and hold
„alert" for 3 second to set the alarm temperature. The outdoor
temperature will blink.
• Press „UP" or „DOWN" to set the maximum value for the temperature
alarm. Confirm your setting by pressing alert. Press „UP" or
„DOWN" to set the minimum value for the temperature alarm.
• Confirm your setting by pressing Alert.
Activating/deactivating the temperature alarms
• If the temperature alarm is activated the
the outdoor temperature. The alarm will sound at the set temperature.
• If temperature alarms are activated then symbols will appear.
,
4
ute
7
ENG
symbol will appear next to

Advertisement