Download Print this page

SABAF 10 Instructions For Use, Maintenance Instructions

Manually-operated gas valve with flame surveillance device for cooking appliances

Advertisement

Quick Links

SABAF S.p.A.
Via dei Carpini, 1
25035 Ospitaletto (Brescia) Italia
TECHNICAL CHARACTERISTICS
INSTRUCTIONS FOR USE, MAINTENANCE INSTRUCTIONS
MODELS 10, 10P, 10PZ, 10X, 10Y
MANUALLY-OPERATED GAS VALVE
WITH FLAME SURVEILLANCE DEVICE FOR COOKING APPLIANCES
CE
EN 437:2003 + A1:2009
AS 4624-2005
EN 126:2012
EN 13611:2007+A1:2011
10, 10P, 10PZ, 10X, 10Y
10, 10X, 10Y, 10P, 10PZ
models
models
(SAI-400154)
(51CL4024)
Revision 06 – set 16
Model 10, 10P, 10X, 10Y, 10PZ
page 1 of 6

Advertisement

loading

Summary of Contents for SABAF 10

  • Page 1 SABAF S.p.A. Via dei Carpini, 1 25035 Ospitaletto (Brescia) Italia TECHNICAL CHARACTERISTICS INSTRUCTIONS FOR USE, MAINTENANCE INSTRUCTIONS MODELS 10, 10P, 10PZ, 10X, 10Y MANUALLY-OPERATED GAS VALVE WITH FLAME SURVEILLANCE DEVICE FOR COOKING APPLIANCES EN 437:2003 + A1:2009 AS 4624-2005 EN 126:2012...
  • Page 2: General Instructions

    0.040 m3/h (test gas: air – pressure drop 100 Pa – EN 126-2012) (inlet variants 15-16) opening angle of max. flow rate 90° 160° (models 10; 10X) – 210° (models 10P; 10PZ) opening angle of min. flow rate leakage  60 cc/h (1 ml/min) (air - pressure 15 kPa) external leak tightness leakage ...
  • Page 3: Maintenance Instructions

    The microswitches are activated by simply pushing the spindle inward or by rotation of the spindle – see table 1. As regards the gas valve model 10, X variant (cap marked X), the control shaft can be also turned 90° clockwise, without any passing of gas, to operate one or more microswitches.
  • Page 4 G 1/8” various M 16 x 1.25 flared tube tube diameter 7 mm compression fitting Gc 1/8” angle 6° various tube diameter 8 mm compression fitting Revision 06 – set 16 Model 10, 10P, 10X, 10Y, 10PZ page 4 of 6...
  • Page 5 25035 Ospitaletto (Brescia) Italia Max. torque values: maximum torque value Component lbf.in Nut + (olive) + tube for outlet of valves Screws for fixing brackets Injectors Revision 06 – set 16 Model 10, 10P, 10X, 10Y, 10PZ page 5 of 6...
  • Page 6 Alternatively, on the component can be marked a four digit code indicating the week (first two digits) and the year of production (last two digits). EXAMPLE: A COMPONENT PRODUCED THE 14 WEEK OF 2004 IS MARKED 1404 Revision 06 – set 16 Model 10, 10P, 10X, 10Y, 10PZ page 6 of 6...

This manual is also suitable for:

10p10pz10x10y