TownSteel XCE9021 Programming And Users Manual

Advertisement

 
XCE9021 Software Specifications 
XCE9021 is a remote control device to be paired with XCE9000 or XME9000 Digital keypad lock for 
emergency lockdown. Pressing button on the remote control unit will immediately lock down all doors 
associated with the remote control unit. 
Remote control emergency device and emergency lock status: 
The purpose of the remote control is for locking the door down (lock down mode) in 
emergencies only. The remote control does not release the lock down mode; it only initiates the 
lock down mode. 
The effective range for remote control is 75 feet inside and 25 feet outside. 
When the door is in lock down mode the red warning LED will flash 3 times per second.   
In the lock down mode you can still enter Master Code, User Code, and Office Code to unlock 
the door, but it does not release the lock down mode.  
Entering the Emergency code will deactivate the lock down mode and stop the LED flashing. 
Remote control emergency device has programmable codes that can be setup by 8 bits DIP 
Switch in the device. The factory setting is: 00000000 
Door lock corresponding remote control code can be set, in order to distinguish between the 
different control groups. door lock the corresponding remote control code, factor Value: 
00,000,000 
One door lock can connect with unlimited number of remote controllers. One remote controller 
can connect with unlimited number of door locks. 
When door locks receive the remote control lock signal, if the code is the same, door locks will 
enter the lock down mode condition. If the code is not the same, door locks will ignore the 
signal. 
 
Program 95‐ Setting the remote control inner code in the emergency condition 
# [Master] ●9 5 ● [the remote control 8bit internal code] ●● 
For example, setting for the emergency remote control code is "11110000" 
1. Enter: # 12345 ● 95 ● 11110000 ● ● 
2. Open the remote control cover, change DIP Switch to "11110000" 
3. Reinstate the remote control, press the emergency button to test that the settings are correct 
Note: XCE9000 and the remote control factory settings are: "00000000" 
Federal Communication Commission Interference Statement
 
This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. 
 
XCE9021 PROGRAMMING AND USER MANUAL 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XCE9021 and is the answer not in the manual?

Questions and answers

Summary of Contents for TownSteel XCE9021

  • Page 1 XCE9021 PROGRAMMING AND USER MANUAL      XCE9021 Software Specifications  XCE9021 is a remote control device to be paired with XCE9000 or XME9000 Digital keypad lock for  emergency lockdown. Pressing button on the remote control unit will immediately lock down all doors  associated with the remote control unit.  Remote control emergency device and emergency lock status:   The purpose of the remote control is for locking the door down (lock down mode) in  emergencies only. The remote control does not release the lock down mode; it only initiates the  lock down mode.   The effective range for remote control is 75 feet inside and 25 feet outside.   When the door is in lock down mode the red warning LED will flash 3 times per second.     In the lock down mode you can still enter Master Code, User Code, and Office Code to unlock  the door, but it does not release the lock down mode.    Entering the Emergency code will deactivate the lock down mode and stop the LED flashing.   Remote control emergency device has programmable codes that can be setup by 8 bits DIP  Switch in the device. The factory setting is: 00000000   Door lock corresponding remote control code can be set, in order to distinguish between the  different control groups. door lock the corresponding remote control code, factor Value:  00,000,000   One door lock can connect with unlimited number of remote controllers. One remote controller  can connect with unlimited number of door locks.   When door locks receive the remote control lock signal, if the code is the same, door locks will  enter the lock down mode condition. If the code is not the same, door locks will ignore the  signal.    Program 95‐ Setting the remote control inner code in the emergency condition  # [Master] ●9 5 ● [the remote control 8bit internal code] ●●  For example, setting for the emergency remote control code is "11110000"  1. Enter: # 12345 ● 95 ● 11110000 ● ● ...
  • Page 2 XCE9021 PROGRAMMING AND USER MANUAL        This equipment generates, uses and can radiate radio frequency energy and, if not installed and  used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  equipment does cause harmful interference to radio or television reception, which can be determined  by turning the equipment off and on, the user is encouraged to try to correct the interference by one of  the following measures:  . Reorient or relocate the receiving antenna.  . Increase the separation between the equipment and receiver.  .  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is ...

Table of Contents