Summary of Contents for B-FORM Comfort

  • Page 2 INDEX • ......................... Pag. 3 • ..................Pag. 5 • ....................... Pag. 7 ITALIA • ...................... Pag. 11 Via Bassa 36 48123 Mezzano (RA) • ........................Pag. 12 • ....................... Pag. 13 • ........................Pag. 15 • ........................Pag. 16 •...
  • Page 3 Built with top-quality materials, the B-FORM thermoforming machines have a 3-year warranty against defects in materials and workmanship. All the components that make up the outer structure of the B-FORM thermoforming machines were manufactured using glass-filled nylon and ABS, making it very light and compact.
  • Page 4 The locking plate, in which the thermoplastic sheets are inserted, is raised and lowered by an electric motor in the B-FORM Comfort and Deluxe version, and manually in the B-FORM Silent version. In addition, the particular design of the plate allows you to use...
  • Page 5 THERMOFORMING TECHNIQUE To obtain the best results with the thermoforming technique, a good plaster model needs to be prepared. To do so we recommend that you to keep in mind the following: • The plaster model can be made with any type of plaster. However, we recommend that ITALIA you use a hard plaster because if you use a soft plaster, a model completely covered with Via Bassa 36...
  • Page 6 Via Bassa 36 • With the B-FORM thermoforming machines there is a molding in an axial direction, in 48123 Mezzano (RA) which the suitably heated sheet descends vertically on the model, surrounding it completely.
  • Page 7: Safety Precautions

    SAFETY PRECAUTIONS Please read and take the following precautions before using the equipment. Positioning ITALIA 1. The thermoforming machine must always be placed on a flat and open surface: Via Bassa 36 48123 Mezzano (RA) Under no circumstances must the thermoforming machine be operated when it is located inside a cabinet.
  • Page 8 - Areas with high temperatures. - Areas near flame sources. 5. Do not place the thermoforming machine on uneven supports, unstable surfaces or surfaces that are subject to frequent vibrations. If the equipment falls, it can cause injury. ITALIA 6. Do not put heavy objects on the device. The objects may fall and cause injury. Via Bassa 36 48123 Mezzano (RA) Power supply...
  • Page 9 sure it conforms to the standards in force in your country. If the power supply cable is defective, please contact the manufacturer or your authorized supplier for a repla- cement. 6. As a rule, please do not use extension cords. Fire or electric shocks may occur. In the event that the use of an extension cord is inevitable, do not use one that is longer than ITALIA 5 meters.
  • Page 10 an unusual smell disconnect power supply cable and contact your local dealer. Pro- longed use may cause a fire or electric shocks. 3. If you do not use the device for long periods, such as for example over the weekend, be sure to disconnect the power supply cable as a precaution.
  • Page 11: Materials Provided

    MATERIALS PROVIDED Thank you for purchasing the B-FORM thermoforming machine. Verify that the package contains all of the following items. If part of the material is missing or damaged, please contact your local dealer. ( ITALIA Via Bassa 36 48123 Mezzano (RA) •...
  • Page 12 CLEANING Do not use flammable sprays near the device. In addition, do not pour water, liquids, or flammable liquids on the device. If these liquids get in this device and come in contact with the electrical parts, this may cause a fire or electric shocks. If something gets into the ITALIA device, disconnect the power supply cable immediately and contact your local dealer.
  • Page 13: Maintenance

    MAINTENANCE 1. The stopper with a hole in it, located at the bottom of the well, must always be free of any debris that may form during the operation of the thermoforming machine. The refore, you must periodically remove the beads from the well and thoroughly inspect ITALIA this area and check the filter located inside it ( Via Bassa 36...
  • Page 14 4. In the construction of the thermoforming machine, high quality materials were used. However, after some years of use the resistance, the seals and some other part may wear down and you may need to replace them. ITALIA Via Bassa 36 48123 Mezzano (RA) Tel.
  • Page 15: Installation

    Turn on the switch located on the rear, and the thermoforming machine is ready for operation ( ). A light will turn on the control panel that will illuminate the logo “B-FORM” to confirm that electric voltage is arriving in the machine. Tel. / Fax: 0544 523326 sales@bartmedical.com ATTENTION: Before operating your thermoforming machine, check the voltage of www.bartmedical.com...
  • Page 16: Warranty

    WARRANTY The B-FORM thermoforming machine is guaranteed for 3 years from the date of purcha- se, for defects recognized in material or manufacture. If during the warranty period a defect is observed, the thermoforming machine will be ITALIA repaired or replaced for free only if:...
  • Page 17 INSTRUCTIONS FOR REPAIRS For any type of repair, please send the B-FORM thermoforming machine to your dealer or directly to our service center. For repairs, we recommend that you follow the following instructions: ITALIA 1. Always send the thermo-molder with a transport document. It should also be accom-...
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Check the following before requesting technical assistance: Insufficient details - This is often caused by an incorrect heating or vacuum time of • the plastic sheet. If your overlay does not have sufficient details, you must prolong the ITALIA heating and/or vacuum time of the plastic sheet.
  • Page 19 ATTENTION: If the problems persist please consult maintenance personnel. Do not try to carry out the maintenance alone since opening the structure of the device may expose the user to the danger of electrical shocks or other hazards. Please contact qualified technical personnel.
  • Page 20 ITALIA Via Bassa 36 Heating plate Knob 48123 Mezzano (RA) Heating plate Sliding sleeve Locking plate Tel. / Fax: 0544 523326 Manopola piastra di serraggio sales@bartmedical.com www.bartmedical.com Well beads Control Keyboard Base Cover...
  • Page 21 Resistance power on button Switch off button of the vacuum pump To correctly use the B-FORM Silent thermoforming machine, please keep in mind of the Tel. / Fax: 0544 523326 sales@bartmedical.com following: www.bartmedical.com 1. Activate the general switch located on the back of the thermoforming ma- chine in the position “I”...
  • Page 22 3. Open the locking plate with the appropriate knob (by pushing and rotating it 180°) and insert the desired thermoplastic sheet. Then close the clamping plate always using the knob ( 4.  Grab both knobs of the locking plate and lift it until the plate reaches the end point ITALIA 5.
  • Page 23 15 - 20 seconds are sufficient), resistance turns off automatically. The vacuum pump stays on for about 1 min and then it and then it switches off automatically. If you want to turn it off before pressing the button (VACUUM) 8.
  • Page 24: Technical Data

    TECHNICAL DATA B-FORM SILENT 230 Volt B-FORM SILENT 115 Volt Item. 9617500 Item. 9617501 Height 33 cm Height 33 cm Width 24 cm Width 24 cm ITALIA Depth 28 cm Depth 28 cm Via Bassa 36 Weight 5,1 kg Weight...
  • Page 25 ITALIA Via Bassa 36 Heating plate Knob 48123 Mezzano (RA) Heating plate Sliding sleeve Locking plate Tel. / Fax: 0544 523326 Manopola piastra di serraggio sales@bartmedical.com www.bartmedical.com Well beads Control Keyboard Base Cover...
  • Page 26 Switch off button of the vacuum pump Button to lower the plate For the correct use of the B-FORM Comfort thermoforming machine, please keep in Tel. / Fax: 0544 523326 sales@bartmedical.com mind the following: www.bartmedical.com 1. Activate the general switch located on the back of the thermoforming ma- chine in the position “I”...
  • Page 27 3.  Open the locking plate with the appropriate knob (by pushing and rotating it 180°) and insert the desired thermoplastic sheet. Then close the locking plate always using the knob ( 4. Raise the locking plate by pressing the button (PLATE): the locking plate rises and stops automatically.
  • Page 28 The vacuum pumpstays on for about 1 min and then it and then it switches off automatically. If you want to turn it off before pressing the button (VACUUM) At the end of the process, the locking plate raises itself a few centimeters from the base (this operation is very useful to preserve longer the O-ring of the locking plate ).
  • Page 29 TECHNICAL DATA B-FORM COMFORT 230 Volt B-FORM COMFORT 115 Volt Item. 9617502 Item. 9617503 Height 33 cm Height 33 cm Width 24 cm Width 24 cm ITALIA Depth 28 cm Depth 28 cm Via Bassa 36 Weight 5,1 kg Weight...
  • Page 30 ITALIA Via Bassa 36 Heating plate Knob 48123 Mezzano (RA) Heating plate Sliding sleeve Locking plate Tel. / Fax: 0544 523326 Manopola piastra di serraggio sales@bartmedical.com www.bartmedical.com Well beads Control Keyboard Base Cover...
  • Page 31 Confirmation button Via Bassa 36 48123 Mezzano (RA) Back button Next button For the correct use of the B-FORM Deluxe thermoforming machine, please keep in mind Tel. / Fax: 0544 523326 sales@bartmedical.com the following: www.bartmedical.com 1. Cleaning of the IR temperature sensor Clean the IR temperature sensor with a soft and dry cloth ( 2.
  • Page 32 Deluxe logo ( Immediately after appears the screen “ ” ( LANGUAGE SELECTION 3. Language selection By pressing direction buttons you can select the desired language and con- ITALIA firm with the confirm button . The selected language is kept in memory at next Via Bassa 36 boot.
  • Page 33 Via Bassa 36 48123 Mezzano (RA) 6.  Thermoforming process The thermoforming machine B-FORM Deluxe allows full automation of the thermo- forming process of square and round sheets. After having selected the thickness of the sheet to be formatted, on the LCD display appears the following screen ( Tel.
  • Page 34 If you are not satisfied of the factory set temperature and you prefer that the sheet is more or less warmed up, the B-FORM Deluxe thermoforming machine gives you the possibility to customize the temperature of each individual sheet.
  • Page 35 8.  Factory temperature reset If you are not satisfied with the personalized temperature, the B-FORM Deluxe thermoforming machine gives you the possibility to restore the factory temperature. Tel. / Fax: 0544 523326 Proceed as follows: sales@bartmedical.com...
  • Page 36 9.  Storing of the temperature of a new type of sheet If you want to thermoform a sheet that It is not stored in the software, the B-FORM Deluxe thermoforming machine gives you the possibility to store up to 10 new sheets.
  • Page 37 10. Extraction of the formatted sheet • At the end of the process, the locking plate raises itself a few centimeters from the base (this operation is very useful to preserve longer the O-ring of the locking plate ). • Turn the heating plate toward left ( ) and then cool the byte.
  • Page 38 11. Thermoforming process of Dual Laminate sheet For thermoforming technique of B-FORM Dual Laminate sheet, at some point in the thermoforming process will be necessary your intervention. This type of sheet needs a double heating: must be heated first on one side and then the other side.
  • Page 39 • Place the plaster model on the perforated plate ( ) or in the well, after ha- ving filled it with beads ( During the heating process appears the following screen ( ATTENTION: to use the well the placement of the plaster model must be done before ITALIA starting the process.
  • Page 40 ATTENTION: to use the well the placement of the plaster model must be done before starting the process. • After the thermoforming process, on the LCD display appears the following screen ). The locking plate lifts itself a few centimeters from the base. ITALIA •...
  • Page 41 If you are not satisfied of the factory set temperature and you prefer that the sheet is 48123 Mezzano (RA) more or less warmed up, the B-FORM Deluxe thermoforming machine gives you the possibility to customize the temperature only the temperature of the soft side.
  • Page 42 another temperature until you do not find the temperature that satisfies you. ATTENTION: you can only customize the temperature of the soft side of the Dual La- minate sheet. ITALIA Via Bassa 36 48123 Mezzano (RA) Tel. / Fax: 0544 523326 sales@bartmedical.com www.bartmedical.com...
  • Page 43 TECHNICAL DATA B-FORM DELUXE 230 Volt B-FORM DELUXE 115 Volt Item. 9617504 Item. 9617505 Height 33 cm Height 33 cm Width 24 cm Width 24 cm ITALIA Depth 28 cm Depth 28 cm Via Bassa 36 Weight 5,1 kg Weight...
  • Page 44 INSTRUCTIONS FOR USE FOR THE “WELL” The presence of the well makes the B-FORM thermoformer machines very efficient and complete ( In the beads of the well, you have the possibility to immerse, to the depth you want, indi- ITALIA vidual teeth, teeth sections or an entire model.
  • Page 45 you want to mold comes out completely from the edge of the well. Finally, cover the entire plaster model with beads and level them, leaving uncovered only the area that you want to mold. ITALIA Via Bassa 36 48123 Mezzano (RA) Tel.
  • Page 46 SYMBOLS This guide uses the following symbols to indicate important information. Always follow the instructions indicated by these symbols. ITALIA ATTENZIONE: This symbol indicates instructions whose non-compliance involves Via Bassa 36 the risk of serious damage to persons or property caused by the incorrect use of the 48123 Mezzano (RA) device.
  • Page 47 DISPOSAL For the disposal of the B-FORM thermoformer machines, please refer to the laws of each country. ITALIA Via Bassa 36 48123 Mezzano (RA) Tel. / Fax: 0544 523326 sales@bartmedical.com www.bartmedical.com...
  • Page 48 VIDEOS ITALIA Via Bassa 36 48123 Mezzano (RA) Tel. / Fax: 0544 523326 sales@bartmedical.com www.bartmedical.com...

This manual is also suitable for: