Nordson EFD 7362738 Operating Manual

Nordson EFD 7362738 Operating Manual

Safety enclosure for automated dispensing systems

Advertisement

Safety Enclosure for Automated Dispensing
Systems
Operating Manual
Electronic pdf files of Nordson EFD
manuals are also available at
www.nordsonefd.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7362738 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nordson EFD 7362738

  • Page 1 Safety Enclosure for Automated Dispensing Systems Operating Manual ™ Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com...
  • Page 2 Thank You! You have just purchased the world’s finest precision dispensing equipment. I want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.
  • Page 3: Table Of Contents

    Service ...................................21 Part Numbers ................................21 Troubleshooting ................................22 Technical Data ................................22 General Block Wiring Diagram (Standard and EU) ....................22 Safety Enclosure I/O Terminal Block Pin Assignments ....................22 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 4: Introduction

    EU Machinery Directive 2006/42/EC, essential for all production requirements. Nordson EFD safety enclosures easily integrate into existing production lines. Each enclosure features an internal lockable electrical control box and integrated wireways that allow easy cable routing for faster, safer setup.
  • Page 5: Nordson Efd Product Safety Statement

    Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 6: Halogenated Hydrocarbon Solvent Hazards

    Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 7: Intended Use

    Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be impaired.
  • Page 8: Fire Safety

    • Test: Verify the operation of features and the performance of equipment using the appropriate sections of this manual. Return faulty or defective units to Nordson EFD for replacement. • Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD representative for information and advice.
  • Page 9: Important Disposable Component Safety Information

    Disconnect and lock out system electrical power. If using hydraulic and pneumatic shutoff valves, close and relieve pressure. For Nordson EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For Nordson EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
  • Page 10: Specifications

    RUN position and START buttons to run programs) (same functionality as the controls on the front of the robot) Large storage area (for use as needed) www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 11: Installation

    Install the articulating arm on the mounting base. Install the keyboard tray on the articulating arm. Use four (4) M4 x 12 screws (customer-supplied) to secure the monitor to the monitor mounting plate. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 12: Install The Robot In The Enclosure

    Use a 4 mm hex key to remove the four (4) existing feet from the robot. Continued on next page www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 13 Open the enclosure doors and use an open- end wrench to install the M5 nuts removed previously, thus securing the robot to the enclosure. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 14: Connect Cables

    - Refer to the Quick Start Guide for the correct cable connections for your system. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 15: Install The Dispensing System And Reinstall The Panels

    Continue to the next procedures to connect inputs / outputs and to power on the complete system for the first time. Example of a fully installed system (EV Series system shown) www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 16: Connect Inputs / Outputs (Optional)

    Pin 24 +24 VDC* Pin 12 Ground Pin 25 +24 VDC* Pin 13 Ground *These signals are not connected to the safety enclosure I/O terminal block. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 17: Initial Startup

    If the light curtain is interrupted by any passing object (such as a hand reaching into the enclosure), the system enters an emergency stop condition. Continued on next page www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 18 8 (“Out 8”) in the DispenseMotion software must be set to Running. DispenseMotion software screens used to set up Inputs / Outputs (refer to the robot operating manual for the complete procedure) www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 19: Operation

    • The light curtain is deactivated, allowing the operator to reach inside the enclosure without triggering an emergency shutdown. • The robot cannot execute a dispense program. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 20: Running A Program

    Controls on the front of an Press the START button to reset the position of the robot. EU safety enclosure Resume normal operation. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 21: Service

    PRO3L, PROPlus3, PROPlus3L 7362766 Small safety enclosure, Europe 7362739 Large safety enclosure E4, E4V, E5, E5V, R4, R4V, PRO4, PRO4L, PROPlus4, PROPlus4L 7362767 Large safety enclosure, Europe www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 22: Troubleshooting

    Robot I/O terminal blocks Front panel controls Safety Enclosure I/O Terminal Block Pin Assignments Refer to “Safety Enclosure I/O Terminal Block Pin Assignments” on page 16. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 23 Safety Enclosure for Automated Dispensing Systems Notes www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 24 NORDSON EFD ONE YEAR LIMITED WARRANTY Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions.

This manual is also suitable for:

736276773627667362739

Table of Contents