Vented Counterflow wall Furnace
FAW55SPPX-1, FAW551SPP
This conversion kit is to be installed by an Empire Comfort Systems, inc. distribu tor (or other
qualified agency
)* in accordance with the manufac turer's instruc tions and all codes and
1
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsi ble for (a) the installation of gas
piping or (b) the connection, installation repair, or servicing of equipment, who is experienced
in such work, familiar with all precau tions required, and has complied with all the requirements
of the authority having jurisdic tion.
ChECk saFETy shuTdowN pErFormaNCE
perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CoNTiNuous iGNiTioN sysTEms
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 3 minutes. Safety shut-off of pilot gas proves complete shutdown
since safety shut-off valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls
operate properly.
part description
Pilot Orifice
Main Burner Orifice
Gas Valve
Conversion Label
33675-2-0219
Gas CoNVErsioN kiT 682161
iNsTaLLaTioN iNsTruCTioNs
FOR CONVERSION TO NaTuraL gaS
modELs usEd oN
warning
warning
parTs LisT
kit Numbers 682161
Empire Comfort Systems Inc. • Belleville, Illinois
direct Vent Counterflow wall Furnace
DVC55SPPX-1, DV551SPP
R3469
P8842
R2148
R1322
Quantity Supplied
1
2
1
1
Page 1