Automatic make-up air damper with transformer
Hide thumbs Also See for MD6T:

Advertisement

AUTOMATIC
MAKE-UP AIR DAMPER
WITH TRANSFORMER
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
2. Do not use the unit in conjunction with any exhaust device other
than compatible BEST, Broan Elite or Broan range hoods.
3. This unit is not designed to provide combustion air for fuel-
burning appliances.
4. Do not connect the unit directly to a combustion appliance of
any type.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
6. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
7. When performing installation, servicing or cleaning the unit, it is
recommended to wear safety glasses and gloves.
8. During extreme weather events including snow storms, ensure
that the intake area for the outside air duct is not blocked and
able to provide a clear pathway for outside air to enter the
system.
9. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
10. When notching or drilling into framing including floor supports,
rim joists, and wall studs, comply with code and manufacturer
limitations on allowable modifications to these structural
members.
11. This unit is intended to be installed within the home in a location
protected from moisture.
12. This unit must be in an accessible location which allows for
inspection of the unit.
13. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in this document.
14. When federal, provincial or state legislation comprises more
restrictive installation and/or certification requirements, the
aforementioned requirements prevail on those of this document
and the installer agrees to conform to these at his own expense.
FOR RESIDENTIAL USE ONLY
MODELS MD6T • MD8T • MD10T
CAUTION
1. Do not locate outside air inlet near hazardous materials or
explosives.
2. Unit shall not be installed to introduce air from crawlspaces,
garages, attics, adjacent dwelling units, or other locations within
the building shell. Unit shall be installed to introduce air directly
from outdoors.
3. Do not run the outside air duct directly above or closer than 2 ft to
any furnace or its supply plenum, boiler, or other heat producing
appliance.
4. Any ductwork used in conjunction with the Damper must be
installed in compliance with all local and national codes that are
applicable.
5. Do not operate the Damper for fresh air introduction until all system
filters, including the central duct system filter, have been installed
per the system design.
6. Please read the unit specification label on the product for further
information and requirements.
7. The Damper's outdoor air intake, ducting, and any filters should be
inspected and maintained on a regular basis.
8. Insulate the duct and damper to prevent build-up of condensation
in cold weather climates. Vapor barriers on both sides of insulation
are recommended.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MD6T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Broan MD6T

  • Page 1 2. Do not use the unit in conjunction with any exhaust device other than compatible BEST, Broan Elite or Broan range hoods. 3. Do not run the outside air duct directly above or closer than 2 ft to any furnace or its supply plenum, boiler, or other heat producing 3.
  • Page 2: Plan The Installation

    MODELS MD6T • MD8T • MD10T Page 2 PLAN THE INSTALLATION • Outside air intake is placed high enough above grade to prevent blockage from snow or other debris such as leaves, and at a mini- Planning the installation first requires selecting the most appropriate mum of 1’...
  • Page 3 MODELS MD6T • MD8T • MD10T Page 3 EXTERIOR WALL INSULATED OUTSIDE INTERIOR WALL AIR DUCT (slope toward wall cap) WALL CAP WITH WALL BIRD SCREEN REGISTER VENTILATION AIR INTAKE (locate away from pollutant sources) MOTORIZED DAMPER REGISTER BOX ADAPTED WITH SLIDE-IN FILTER (optional) Damper and outside air duct connected directly to a ceiling, floor, or wall register.
  • Page 4: System Operation

    Because these Broan Elite or Broan range hood is operating, thereby creating a known, fans pull air out of the house, this air needs to be replaced with “new” air controlled point for fresh air to enter the home while air is being exhausted from outdoors.
  • Page 5 6. Can I use the Broan Automatic Make-Up Air Damper with other 9. What happens after a power outage? equipment in my home? The Damper system and the associated exhaust devices will not lose No.

This manual is also suitable for:

Md8tMd10t

Table of Contents