Table 1: PLPROFILE1 MKII LED Luminaire AC Input
Wire Color
Brown
Green/Yellow

3. Connecting to the DMX512 Network

Basic DMX512 installation consists of connecting multiple PLPROFILE1 MKII LED Luminaires together (up to 30
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first PLPROFILE1 MKII LED Luminaire. Another cable runs from the other DMX connector on the
first unit to a DMX connector on the next PLPROFILE1 MKII LED Luminaire (or DMX512 device to be controlled).
Note: For more information on DMX512 networking and systems, refer to
page
1. For PLPROFILE1 MKII LED Luminaire DMX Mapping, refer to
PLPROFILE1 MKII LED Luminaires
1
8
INSTALLATION AND SET UP
Connections
Main / Line (100 to 240VAC)
Blue
DMX512
DMX512
(from console or
control device)
Pin 1
Data Thru
Cable Pinout
Common
(Drain)
5
2
4
3
Male Conn
Figure 4: PLPROFILE1 MKII LED Luminaires - DMX512 Connections
Purpose
Neutral
AC Input Connector
Ground
(on back of unit)
DMX512
(out from first
to second luminaire)
DMX512 Connections
Pin 2
Pin 3
Data (-)
Data (+)
Not Used
PLPROFILE1 MKII LED Luminaires
Neutral
Ground / Earth
"Additional Resources for DMX512" on
"DMX CONTROL" on page
(out to the next luminaire or
DMX512 controlled device)
Pin 4
Pin 5
Data In
Cable Pinout
Not Used
5
4
Female Conn
Main /
Line
21.
1
2
3