Feig Electronic ID ISC.LRM200-A/B Installation Instructions Manual
Feig Electronic ID ISC.LRM200-A/B Installation Instructions Manual

Feig Electronic ID ISC.LRM200-A/B Installation Instructions Manual

Identification system obid i-scan

Advertisement

Quick Links

®
®
O B ID
i -scan
Installation Instructions
ID ISC.LRM200-A/B
M00602-1e-ID-B.DOC

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID ISC.LRM200-A/B

  • Page 1 ® ® O B ID i -scan Installation Instructions ID ISC.LRM200-A/B M00602-1e-ID-B.DOC...
  • Page 2 Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information.
  • Page 3: Table Of Contents

    Installation Instructions ID ISC.LRM200-A/B Contents: 1. Safety Instructions / Warning ..................4 2. Features of the ID ISC.LRM200-A/B Reader Module ..........5 2.1. Features ..........................5 2.2. Available modules ......................5 3. Installation and wiring ....................6 3.1. Terminals, sockets and switches ..................7 3.2.
  • Page 4: Safety Instructions / Warning

    The device must be installed and electrically connected in accordance with the recognized technical regulations in the country where it is being installed and according to other regional codes.. • The base plate and the attached heat dissipater may become quite hot during operation. Page 4 of 20 FEIG ELECTRONIC GmbH...
  • Page 5: Features Of The Id Isc.lrm200-A/B Reader Module

    2. Features of the ID ISC.LRM200-A/B Reader Module 2.1. Features The ID ISC.LRM200-A/B Reader Module has been developed for reading passive data tags, so- called „Smart Labels“, at an operating frequency of 13.56 MHz. It is suitable for all applications in which long reading distances are required.
  • Page 6: Installation And Wiring

    Reader regulates its output power down until the upper temperature limit of its final stage is reached again. 120 m m 110 m m 100 m m Fig. 3-1: Dimensional drawing of the ID ISC.LRM200-A/B Reader Page 6 of 20 FEIG ELECTRONIC GmbH...
  • Page 7: Terminals, Sockets And Switches

    Installation Instructions ID ISC.LRM200-A/B 3.1. Terminals, sockets and switches Upper circuit board J401 J400 Lower circuit board Fig. 3.1-1: Top view: Upper and lower circuit board FEIG ELECTRONIC GmbH Page 7 of 20...
  • Page 8: Antenna Connection

    To achieve optimum read distances the length of the antenna lead-in cables should be 3.6 m ±0.1 m. • When connecting an antenna, ensure that it does not exceed the limit values allowed by the national regulations for radio emissions. Page 8 of 20 FEIG ELECTRONIC GmbH...
  • Page 9: Supply Voltage

    Installation Instructions ID ISC.LRM200-A/B 3.3. Supply voltage The supply voltage of 24 VDC is connected on Terminal X3 on the lower circuit board. The cable length between the power supply and the Reader Module must not exceed 3 m. Note: •...
  • Page 10: X7: Inputs (Optocoupler Isolated)

    5 V ... 10 V 270 Ω 11 V ... 15 V 560 Ω 16 V ... 20 V 820 Ω 21 V ... 24 V Table 3.4-1: Required external dropping resistor R Page 10 of 20 FEIG ELECTRONIC GmbH...
  • Page 11: X6: Output (Optocoupler Isolated)

    Installation Instructions ID ISC.LRM200-A/B 3.5. X6: Output (optocoupler isolated) The transistor connections, collector and emitter, of the two optocoupler outputs are galvanically isolated from the Reader electronics and brought out on Terminal X8 without any additional cir- cuitry. The outputs must therefore be supplied externally.
  • Page 12: X11: Relay

    • The relay outputs are configured for max. 24 V DC / 60 W. • The relay outputs are designed to switch resistive loads only. If using an inductive load, the relay contacts must be protected by means of an external protection circuit. Page 12 of 20 FEIG ELECTRONIC GmbH...
  • Page 13: X9: Rs485 Interface

    Installation Instructions ID ISC.LRM200-A/B 3.7. X9: RS485 interface The asynchronous interface can be configured for RS485 or RS232 (see Section 5.1: Interface configuration using jumpers). The RS485 interface is configured on X9. The transmission parameters can be software configured. Configuration for X9 (RS485 interface):...
  • Page 14: X10: Rs232 Interface

    ID ISC.LR200 9-pin sub-D female <−> Pin 5 X10 / 1 <−> Pin 3 X10 / 2 <−> Pin 2 X10 / 3 Fig. 3.8-1 : Wiring example for connecting the RS232 interface Page 14 of 20 FEIG ELECTRONIC GmbH...
  • Page 15: Control And Display Elements

    Installation Instructions ID ISC.LRM200-A/B 4. Control and display elements 4.1. LED´s Table 4.1-1 shows the configuration of the LED´s. Name Description LED V1 (green) "RUN-LED" Indicates proper running of the internal Reader software Flashing rate ca. 1 Hz LED V2 (red)
  • Page 16: Buttons / Switches

    Reset button 1 - 3: Setting data bus addresses (0 ... 7) not used Note : To set the bus address using S2, the Reader must be set to software address „0“ (factory setting). Page 16 of 20 FEIG ELECTRONIC GmbH...
  • Page 17: Startup

    Installation Instructions ID ISC.LRM200-A/B 5. Startup 5.1. Interface configuration using jumpers Jumpers J400 – J401 are used to configure the asynchronous interface for RS232 or RS485. Jumper RS232 RS485 1 - 2 2 - 3 1 - 2 2 - 3 Jumpers J403, J405 and J407 can be used to insert the termination resistors which may be re- quired for the RS485 interface.
  • Page 18: Setting Addresses For Bus Operation

    Addresses are assigned through the host computer. The software is used to assign addresses “0” to “253” to the Reader. Note: Since all Readers are factory set to Address 0, they must be connected and configured one after the other. Page 18 of 20 FEIG ELECTRONIC GmbH...
  • Page 19: Technical Data For Id Isc.lrm200-A/B

    Installation Instructions ID ISC.LRM200-A/B 6. Technical Data for ID ISC.LRM200-A/B Mechanical Data • Dimensions ( W x H x D ) 120 x 160 x 69 mm • Weight 650 g Electrical Data • Supply voltage 24 V DC +5%/-1% Ripple : max.
  • Page 20 : 30 g Applicable norms • Radio approval EN 300 330 - Europe FCC 47 CFR Part 15 - USA • EMC EN 300 683 • Safety EN 60950 - Europe UL 1950 - USA Page 20 of 20 FEIG ELECTRONIC GmbH...

Table of Contents