CyberChill CCB 550 Operating Instructions Manual

CyberChill CCB 550 Operating Instructions Manual

Glass door merchandiser

Advertisement

OPERATING INSTR UCTIONS:
CCB / CCT 550 Glass Door Merchandiser
V2/2017
CyberChill Refrigeration
!
P.O. Box 7200
Baulkham Hills BC
NSW 2153 Australia
1300 072 000
www.cyberchill.com.au
1
!
!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCB 550 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CyberChill CCB 550

  • Page 1 OPERATING INSTR UCTIONS: CCB / CCT 550 Glass Door Merchandiser V2/2017 CyberChill Refrigeration P.O. Box 7200 Baulkham Hills BC NSW 2153 Australia 1300 072 000 www.cyberchill.com.au...
  • Page 2 This page is intentionally left blank!
  • Page 3: Table Of Contents

    Contents General Hazards Electrical Connection Unpacking Installation Ventilation Shelves / Pans / Slides Fitting the Shelves Gasket Replacement Replacing the LED Tube Removing Cassette Bottom Mount Removing Casette Top Mount Initial Start Up Checks Using Your New Piece of Refrigeration Equipment Commissioning Instructions Fault Finding Alarms...
  • Page 4: General Hazards

    General Hazards All moving parts of the refrigerator are suitably guarded any repairs and maintenance should only be carried out by a qualified professional Electrical Connection This cabinet is supplied with a flexible power cable that has a molded 3 pin plug on the end. The plug needs to be accessible once the equipment is placed in its final position.
  • Page 5: Shelves / Pans / Slides

    Shelves The shelves may be positioned at different heights to suit various products. Each shelf is held in place by 4 shelf clips which engage in the shelf support strips. To Fit the shelves 1- Unpack the wire shelves and shelf clips from inside the cabinet.
  • Page 6: Removing Cassette Bottom Mount

    Removing Cassette Should maintenance be required on the cassette the following steps are to be followed; 1. Disconnect the cabinet from the mains power supply 2. Pull on the bottom of the kick panel to dislodge it from the cabinet (fig.1) 3.
  • Page 7: Removing Casette Top Mount

    Removing Cassette – Top Mount Should maintenance be required on the cassette the following steps are to be followed; Disconnect the cabinet from the mains power supply Pull on the top of the kick panel to dislodge it from the cabinet (fig.1) Lift the kick panel to remove and set aside, this is recommended to avoid causing damage (fig.2) Unplug the 4 plugs into the electrical compartment (fig.3)
  • Page 8: Initial Start Up

    Initial Start Up Plug the molded plug into a suitable socket. If necessary, push the button on the controller to start the unit. The cabinet air temperature will be displayed once the unit is running. To standby the unit when running, press and hold the button for 3 seconds.
  • Page 9: Commissioning Instructions

    (starting) temperature is determined by the differential. Defrosting All CyberChill refrigerated cabinets are fitted with a fully automated defrost system that ensures the cooling system remains free from ice under normal conditions. If a manual defrost is required, this can be activated by pressing , for 2 seconds which will terminate automatically once the pre-programmed temperature has been reached.
  • Page 10: Fault Finding

    If this doesn’t solve the problem, please call CyberChill on 1300 072 000. When requesting a service call, please find the manufacturers data plate and provide the model, serial number and details of any fault codes that are displayed.
  • Page 11 Wiring Diagram...
  • Page 12: Lae Controller Wiring Diagrams

    Notes:...
  • Page 13 ……………………………………………………………………. Model: ………………………………………………………… Serial Number: AUS Patent App. No. 2015201249 NZ Patent App. No. 705857 GWP Values for Refrigerants: R1234ze – <1 R290 – < 3 R134a – 1430 R404a – 3922 These units contain fluorinated greenhouse gases covered by the F Gas directive claration of Conformity References: Low Voltage Directive 2006/95/EC EC Machinery Directive 2006/42EC...

This manual is also suitable for:

Cct 550

Table of Contents