GENERAL Each branch on the extension line must have: A protective resistor of 10 Ω/1W Exchange cabinet BDV BS 101 01 is designed to be (REN 195 42/1) connected in series furnished with Printed Board Assemblies (hereafter = between cabinet and MDF boards or PBAs) belonging to ERICSSON’s PBX-...
INSTALLATION INSTRUCTION 7(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 HOW TO OPEN THE INSTALLATION CABINET The PBX can be delivered as a customer configured unit or the add-in boards are delivered separately. The Unpack the exchange cabinet.
SVB BS 101 02/_ connector Note: The mains current rating stated on the label is the maximum current of the charger version. Bottom view of cabinet BDV BS 101 01 BATT. Shelf All line interfaces in the PBX are protected in...
01). 250VAC 6,3 A T. NOTE: This fuse NGH 243 01/6300 can be ordered from Ericsson but is a non-accessible and non-user serviceable part. Only authorised personnel is allowed to change the fuse. Contact the local supplier in this matter.
01). ALLOCATION In principle, all board positions in cabinet BDV BS 101 01 can be used for arbitrary configurations with PBAs belonging to PBX-system ASB 150 02. The boards are equipped with ground brackets on the top and bottom. When installing make sure to fasten the boards with the supplied screws.
INSTALLATION INSTRUCTION 11(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Connection of CM-Boards Connect the correct type of call metering board, according to the figure below, on BTU-A board ROF 157 5110/_ or ROF 157 5127/_ and in the same fashion on the BTU-C board ROF 157 5111/_.
Page 11
INSTALLATION INSTRUCTION 12(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Extension Power Demand CURRENT CONSUMPTION CURRENT CONSUMPTION TELEPHONES TELEPHONES Typ (mA) Max (mA) Typ (mA) Max (mA) DBC 210 DBC 214 BASIC...
INSTALLATION INSTRUCTION 13(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 BTU-A (ROF 157 5110/-) and Power failure circuit (PFC) BTU-A2 (ROF 157 5120/_) In the event of mains failure and if no battery back up...
INSTALLATION INSTRUCTION 14(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 BTU-C (ROF 157 5111/-) Connection field 4 Not always mounted (market-dependent) Connection field 4 and 6 Connection of analogue telephone PFa0 Connection to...
Page 14
INSTALLATION INSTRUCTION 15(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 BTU-B (ROF 157 5121/_) BTU-B2 (ROF 157 5121/_) Applies for indices 1 and 3 Applies for indices 4 and 5 The BTU-B provides connection for up to 8 physical links and every physical link can be configured as a S-...
INSTALLATION INSTRUCTION 16(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Note: at the end of each line a termination resistor (refer to documentation of the TE) is also equipped must be installed (e.g. in the last wall outlet).
Page 16
INSTALLATION INSTRUCTION 17(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 BTU-D (ROF 157 5112/1) and REG (ROF 157 5112/2) Connection field 6 The DIP-switch is shown with both contacts in OFF position...
Page 17
If a twisted pair connection should be installed and the requirements of EN 55022, class B have to be fulfilled, a ferrite is available with the ERICSSON ordering 1) Factory setting number STF 82 601. Taking the cable and making...
Page 19
INSTALLATION INSTRUCTION 20(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 6.10.1 Paging connection The figure shows how to connect the paging equipment Ericall Contactor with 2 wire speech. The PBX sends paging information to paging system (pin 6A18) using M1 contact, and information about ’paging in progress’...
Page 20
INSTALLATION INSTRUCTION 21(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 6.10.2 Four wire speech connection The four wire speech and signalling connection has the benefit of not needing additional signalling wires. There are two different types of signalling supported: Cailho E&M-signalling (balanced battery).
Page 21
INSTALLATION INSTRUCTION 22(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 6.10.3 E&M-signalling Signalling on E & M wires is done either using one or two E&M pairs depending on what is required. Using just E1 and M1 is a very common practice.
INSTALLATION INSTRUCTION 24(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 6.12 CPU-D4 (ROF 157 5124/_) Connections on the CPU-D4 Similar to the previous versions this board provides the V.24 interfaces but additionally the RS-485 interface for longer ranges.
Page 24
INSTALLATION INSTRUCTION 25(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 wise data is lost if printer is OFF. The range of the in- terface is up to 1200m. Several converters may be used but with the following...
INSTALLATION INSTRUCTION 27(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 6.14 VMU-HD (ROF 157 5126/1) 990/1 990/2 FUNCTION ON or To install unpack the VMU-HD board with the mounted 16 channels, no register function hard disk.
INSTALLATION INSTRUCTION 28(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 INTEGRATED CORDLESS plug is available for various numbers of cordless tele- phones. For up to 8 portables no plug is required. The Integrated Cordless (IC) is a digital cordless tele-...
INSTALLATION INSTRUCTION 29(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Practically, this table is used to calculate from a given GOS and Erlang value the number of portable users. Speech Grade of service (GOS)
Page 29
INSTALLATION INSTRUCTION 30(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 IC-CU2 (ROF 157 5131/_) (GAP-Protocol) LEDs Switch 1 and 2 must have the RP error same position. ON (default) yellow Individual blocked 48V from the backplane.
INSTALLATION INSTRUCTION 31(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Base Station ( KRCNB 201 03/_ KRCNB 301 01/_ The Base Station (BS) enables radio communication between the Integrated Cordless system and the portable telephones.
Page 31
INSTALLATION INSTRUCTION 32(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Ground floor corridor intermediate floor Base Station 1 3,5m e.g. 40m 7.4.2 Base Stations Cabling Using a four-pair cable or more-pair cable, the free cable pairs can be used as additional power wires (EPP) to increase the feeding distance and reduce overall power consumption (by reducing the ohmic resistance) to the BS.
INSTALLATION INSTRUCTION 33(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 SC0-a 48V external -48V from source SC0-b backplane (optional) S1 & 2 SC1-a Data/power SC1-b connector 1 SC0-a EPPa up to 2 power pairs "EPP...
Page 33
INSTALLATION INSTRUCTION 34(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 7.4.5 Base Station (KRC NB 203 01/_) The Base Station (BS) is supplied with a drilling template to mount the unit and 2 antennas with TNC connectors.
Page 34
INSTALLATION INSTRUCTION 35(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 7.4.6 Base Station (KRCNB 301 01/_) LED2 Front view Rear view LED1 RJ 45 modular jack SC = Serial Channel Factory testing...
Page 35
INSTALLATION INSTRUCTION 36(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 The BSs can be mounted vertically or horizontally. Mount the BSs at places and positions as determined in the system configuration plan. The BS must be placed such that it is not facing large metal objects such as large heating pipes, machines.
Page 36
INSTALLATION INSTRUCTION 37(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Cable ducts When the BS is mounted to the wall, cable ducts can be used to route the wiring through. • Fix the cable duct to the wall in one of the positions shown in left figure.
Page 37
INSTALLATION INSTRUCTION 38(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 7.4.7 Power Feeding of Base Stations When using any of the adapters mentioned below care must be taken to configure the IC-CU2 boards for local BS feeding.
902 0001/800) leading to the boards. • In case a separate Ericsson MDF has to be installed, prefabricated cables are used between the MDF and board connectors in the exchange cabinet. These cables have EURO-connectors mounted at one end for connection to the board.
INSTALLATION INSTRUCTION 40(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Cables for BDV 113 08 8.1.1 MDF cables Krone colour: wt bl wt or wt gn wt br rd bl rd or rd gn rd br...
Page 40
INSTALLATION INSTRUCTION 41(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 8.1.2 Coax cable for BTU-D length a part number usege coax cable 75 Ω for BTU-D TSR 225 1304/20000 20000mm 8.1.3 V.24 cables...
Page 41
INSTALLATION INSTRUCTION 42(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 8.1.4 Battery connection cable length a part number usege part of NTM BS 101 02 230mm Battery connection cable 8.1.5 Mains power cables...
Page 42
INSTALLATION INSTRUCTION 43(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Cable for Brazil, Mexico, Venezuela etc. length a part number usege RPM 945 324 2500mm mains power cable 125V 10A Cable for Australia, New Zealand, China etc.
Each cable that is connected to a PBX type ASB 150 should be marked on the cable’s designation holder The BDV BS 101 01 is factory equipped with a Krone with the label set SVH 277 003/4, supplied for this snap-in holder accommodating a maximum of 8 Krone purpose.
INSTALLATION INSTRUCTION 45(46) Prepared Subject responsible Documentnumber 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 Door Interface Unit (DIU) sounds loud enough and clear other wise repeat the procedure. (BFY BS 10101/1) • No voice connection to the speaker of the telephone.Turn the mic potentiometer screw two...
INSTALLATION INSTRUCTION 46(46) Documentnumber Prepared Subject responsible 1531-BDV BS 101 01 Uen Doc respons/Approved Checked Date Reference 1998-05-29 INSTALLATION OF ALARM INTERFACE UNIT Line to exchange DBY BS 410 01/1 nc ba bb nc line to exchange ba and bb are the...
Exchange cabinet BDV BS 101 05 is designed to be furnished with Printed Board Assemblies (hereafter = An overvoltage arrester (gas discharge boards or PBAs) belonging to ERICSSON’s PBX- tube) for quenching surges to protective system ASB 150 02. System functions, desired by the...
INSTALLATION INSTRUCTION 6(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 HOW TO OPEN THE INSTALLATION CABINET The PBX can be delivered as a customer configured unit or the add-in boards can be delivered separately. Unpack the exchange cabinet.
MFU are working with interface TNV. All other boards and the V.24 port work with interface SELV. 4.2.1 The ferrites, with the ERICSSON ordering number snap-on STF 82 601, should be situated close to the slot where wrist strap connector the cables are led out of the cabinet.
The PSU is equipped with a mains fuse rated 250VAC 6,3 A T. NOTE: This fuse NGH 258 03/630 can be ordered from Ericsson but is a non-accessible and non-user Power switch Label does not serviceable part. Only authorised personnel is disconnect allowed to change the fuse.
INSTALLATION INSTRUCTION 9(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Power feeding with an external DC supply When the PBX is supplied with power by an external battery with 48V nom. (44 - 56V), the installation of a power supply equipped with a battery charger (BML BS 101 01/_) is required.
INSTALLATION INSTRUCTION 10(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Connection of CM-Boards Connect the correct type of call metering board, according to the figure below, on BTU-A board ROF 157 5110/_ or ROF 157 5127/_ and in the same fashion on the BTU-C board ROF 157 5111/_.
Page 56
INSTALLATION INSTRUCTION 11(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.3.2 Extension Power Demand CURRENT CONSUMPTION CURRENT CONSUMPTION TELEPHONES TELEPHONES Typ (mA) Max (mA) Typ (mA) Max (mA) DBC 210 BASIC OPERATOR DBC 214 DBC 199 DBC 663...
INSTALLATION INSTRUCTION 12(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 BTU-A (ROF 157 5110/_) and Power failure circuit (PFC) BTU-A2 (ROF 157 5120/_) In the event of mains failure and if no battery back-up is available for the PBX, there are normally 2 lines on On delivery from the factory both contacts are in the OFF the BTU-A and BTU-C (see under BTU-C on next...
Page 58
INSTALLATION INSTRUCTION 13(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 BTU-C (ROF 157 5111/_) Connection field 4 Not always mounted (market-dependent) Connection field 4 and 6 Connection of analogue telephone PFa0 Connection to YELLOW The index number ELU-A board...
Page 59
INSTALLATION INSTRUCTION 14(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 BTU-B (ROF 157 5121/_) BTU-B2 (ROF 157 5121/_) Applies for indices 1 and 3 Applies for indices 4 and 5 The BTU-B provides connection for up to 8 physical links and every physical link can be configured as a S- or T-interface in point-to-point or multi-point mode.
INSTALLATION INSTRUCTION 15(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Note: at the end of each line a termination resistor (refer to documentation of the TE) is also equipped must be installed (e.g. in the last wall outlet). with a SBCX or equivalent.
Page 61
INSTALLATION INSTRUCTION 16(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 BTU-D (ROF 157 5112/1) and REG (ROF 157 5112/2) Connection field 6 The DIP-switch is shown with both contacts in OFF position S/T-Interface for connecting trunks and S-terminals...
If a twisted pair connection should be installed and the requirements of EN 55022, class B have to be fulfilled, a ferrite is available with the ERICSSON ordering 1) Factory setting number STF 82 601. Taking the cable and making...
Page 64
INSTALLATION INSTRUCTION 19(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.10.1 Paging connection The figure shows how to connect the paging equipment Ericall Contactor with 2 wire speech. The PBX sends paging information to paging system (pin 6A18) using M1 contact, and information about ’paging in progress’...
Page 65
INSTALLATION INSTRUCTION 20(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.10.2 Four-wire speech connection The four-wire speech and signalling connection has the benefit of not needing additional signalling wires. There are two different types of signalling supported: Cailho E&M-signalling (balanced battery).
Page 66
INSTALLATION INSTRUCTION 21(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.10.3 E&M-signalling Signalling on E & M wires is done either using one or two E&M pairs depending on what is required. Using just E1 and M1 is a very common practice.
INSTALLATION INSTRUCTION 22(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.11 CPU-D_ (ROF 157 5118/_) and Connections on the CPU-D_ AUX_(ROF157 5119/_) For connection of the TEMPERATURE SENSOR KIT, INSTALLATION INSTRUCTION (1531-RPM 603 Before installing the board mount the system software 339).
INSTALLATION INSTRUCTION 24(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 It is possible to use a variety of converters. However 6.13 ELU-A and ELU-D with the following converters: IC-485SI of ARP DATA- CON and 232<->485/422 Converter Plus IC-109AE of The relevant boards are: Black Box Corp.
Page 70
INSTALLATION INSTRUCTION 25(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Connection field 6 at front of ELU-D(3) and ELU-A (LA16) (LA17) (LB16) (LB17) (LA18) (LA19) (LB18) (LB19) (LA21) (LA20) (LB21) (LB20) (LA23) (LA22) Extension Line (LB22)
INSTALLATION INSTRUCTION 26(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.14 MFU (ROF 157 5132/_) Board disconnected RYS102 538/2 VMU,ELU-A/D yellow Line blocked green Line busy RYS102 538/1 COMPACT S41 is for S42 refer to next page FLASH CARD...
Page 72
The MFU board can use only flash cards supplied by When selecting S- or T-interfaces start by setting the T- ERICSSON. These flash cards are delivered with a interfaces using switches 4, 3, 2 and 1 in consecutive control file called DISK.ULK containing a licence key.
INSTALLATION INSTRUCTION 28(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 6.15 VMU-HD (ROF 157 5126/1) 990/1 990/2 FUNCTION (ROF 157 5126/3) w. Flash Card ON or 16 channels, no register function For installation unpack the VMU-HD board with the 8 channels with MFC detection mounted hard disk.
INSTALLATION INSTRUCTION 29(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 INTEGRATED CORDLESS The Integrated Cordless (IC) is a digital cordless telephone solution complying to the DECT standard providing wire- less connection for up to 108 portables with the A-protocol and 210 portables in GAP-protocol applications. Several components comprise a complete system.
Page 75
INSTALLATION INSTRUCTION 30(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Speech Grade of service (GOS) IC-CU2 circuits 0.5% 0.1% 3.6 Erl. 3.2 Erl. 2.7 Erl. 2.1Erl. For the calculation it is necessary to estimate the time the portables actually make calls. The table below shows the Erlang value depending on the estimated mean call-minutes for a portable telephone.
INSTALLATION INSTRUCTION 31(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 IC-CU2 (ROF 157 5131/_) (GAP-Protocol) LEDs Switch 1 and 2 must have the RP error same position. ON (default) yellow Individual blocked green 48V from the backplane.
INSTALLATION INSTRUCTION 32(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Base Station ( KRCNB 201 03/_ KRCNB 301 03/_ The Base Station (BS) enables radio communication between the Integrated Cordless system and the portable telephones.
Page 78
INSTALLATION INSTRUCTION 33(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Ground floor corridor intermediate floor Base Station 1 3,5m e.g. 40m 7.4.2 Base Stations Cabling Using a four-pair cable or more-pair cable, the free cable pairs can be used as additional power wires (EPP) to increase the feeding distance and reduce overall power consumption (by reducing the ohmic resistance) to the BS.
Page 79
INSTALLATION INSTRUCTION 34(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 SC0-a 48V external -48V from source SC0-b backplane (optional) S1 & 2 SC1-a Data/power SC1-b connector 1 SC0-a EPPa up to 2 power pairs "EPP carrying V0 and V1 CLC x...
Page 80
INSTALLATION INSTRUCTION 35(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 7.4.5 Base Station (KRC NB 203 01/_) The Base Station (BS) is supplied with a drilling template to mount the unit and 2 antennas with TNC connectors. Mount the unit in a suitable location to provide the best communication coverage.
Page 81
INSTALLATION INSTRUCTION 36(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 7.4.6 Base Station (KRCNB 301 03/_) LED2 Front view Rear view 8 pin LED1 modular plug SC = Serial Channel Factory testing Data/power Data/power EPP = Express Power Pair...
Page 82
INSTALLATION INSTRUCTION 37(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Fixing the mounting bracket to a wall Fix the mounting bracket (see figure below) to the wall as follows: Hold the mounting bracket with its flat side against the wall such that the text ‘TOP’ is the right way up, and mark the two holes.
Page 83
INSTALLATION INSTRUCTION 38(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 When the BS is mounted to the wall, cable ducts can be used to route the wiring through. • Fix the cable duct to the wall in one of the positions shown in the left figure.
Page 84
INSTALLATION INSTRUCTION 39(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 7.4.7 Power Feeding of Base Stations When using any of the adapters mentioned below care must be taken to configure the IC-CU2 boards for local BS feeding.
No stubs and/or branches may exist on digital extension lines, as they could cause transmission problems. • In case a separate Ericsson MDF has to be installed, prefabricated cables are used between the MDF and board connectors in the exchange cabinet. These cables have EURO-connectors mounted at one end for connection to the board.
Page 86
Cable with 8 pairs, mounted with: TSR BS 902 0001 /1500 1500 mm standard cable for external MDF ERICSSON plug and Krone bar /3000 3000 mm MDF cable for existing MDF ERICSSON plug TSR 902 0444/1 1500 mm standard cable for external MDF...
Page 87
INSTALLATION INSTRUCTION 42(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 8.1.2 Coax cable for BTU-D length a part number usage coax cable 75 Ω for BTU-D TSR 225 1304/20000 20000mm 8.1.3 V.24 cables only on TSR 902 0466 length a Wiring of cables:...
Page 88
INSTALLATION INSTRUCTION 43(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 8.1.4 Battery connection cable length a part number usage part of NTM BS 101 28 3000mm Battery connection cable 8.1.5 Mains power cables Cable for EUROPE length a part number...
Page 89
INSTALLATION INSTRUCTION 44(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Cable for Brazil, Mexico, Venezuela etc. length a part number usage RPM 945 324 2500mm mains power cable 125V 10A Cable for Australia, New Zealand, China etc. length a part number usage...
Page 90
INSTALLATION INSTRUCTION 45(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Cable for India and South Africa length a part number usage RPM 945 325 2500mm mains power cable 250VAC 10A Cable for Italy length a part number usage...
INSTALLATION INSTRUCTION 46(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 MARKING OF CABLES External MDF SXK 106 4139/1 Unpack the MDF cabinet and remove its front cover. Each cable that is connected to a PBX type ASB 150 Mount the MDF cabinet on its designated position.
INSTALLATION INSTRUCTION 47(48) Prepared Subject responsible Documentnumber 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 Door Interface Unit (DIU) sounds loud and clear enough other wise repeat the procedure. (BFY BS 10101/1) • No voice connection to the speaker of the telephone.Turn the mic potentiometer screw two Installation: turns clock wise.
INSTALLATION INSTRUCTION 48(48) Documentnumber Prepared Subject responsible 1531-BDV BS 101 05 Uen Doc respons/Approved Checked Date Reference 1999-07-15 INSTALLATION OF ALARM INTERFACE UNIT Line to exchange DBY BS 410 01/1 nc ba bb nc line to exchange ba and bb are the connectors to the alarm button nc are not used wires...
The exchange cabinet BDV 113 08 can be furnished with Printed Board Assemblies (PBAs or boards) be- longing to ERICSSON’s PBX-system ASB 150 02. The desired system functions are made possible by means of the appropriate boards and system programming.
INSTALLATION INSTRUCTION 6(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 UNPACKING INSTALLATION Unpack the exchange cabinet and remove its front The PBX cabinet with the power supply in the back is cover. to be mounted on an indoor wall. A mains outlet must be provided near the equipment and shall be easily accessible.
INSTALLATION INSTRUCTION 7(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 PBX with more than one cabinet A system comprising more than one cabinet is to be expanded in the following way: Remove inserted PBAs from cabinet (if necessary) Prepare all cabinets included in the PBX by removing the break-off piece...
INSTALLATION INSTRUCTION 8(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 4.2.2 Wall mounting Safety Rules Mount brackets (SXA 112 4406/3), for all To fulfil electrical safety requirements IEC 950/ cabinets, on the wall. See figure below EN 60950 respectively EN 41003, the exchange must be connected to protective earth.
INSTALLATION INSTRUCTION 9(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 Power Supply Note: The PBX shall have its own mains fuse and must be connected to an earthed mains outlet The power supplies listed below are designed to be This transformer is available for the following mains powered by sinusoidal mains voltages: voltages:...
INSTALLATION INSTRUCTION 10(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 This graph shows the dependency of mains voltage deviation to available DC output current. This will result in reduced line length for digital instruments.
INSTALLATION INSTRUCTION 11(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Power supervision on ELU-A The ELU-A board is equipped with an automatic traffic limiter restricting the internal power dissipation on the board to a maximum of 12 W.
Page 105
INSTALLATION INSTRUCTION 12(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Extension Power Demand CURRENT CONSUMPTION CURRENT CONSUMPTION TELEPHONES TELEPHONES Typ (mA) Max (mA) Typ (mA) Max (mA) DBC 210 DBC 214 BASIC OPERATOR...
5.2.1 The ferrites, with the ERICSSON ordering number STF 82 601, should be situated close to the slot where the cables are led out of the cabinet. Two turns through the ferrite core are sufficient to comply with EN 55022 Class B and to avoid disturbances in non-industrial, residential (home) usage.
INSTALLATION INSTRUCTION 15(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 BTU-A (ROF 157 5110/_) and Power failure circuit (PFC) BTU-A2 (ROF 157 5120/_) In the event of mains failure and if no back-up battery is connected to the PBX, a relay on the BTU-A and On delivery from the factory both contacts are in the BTU-C (see under BTU-C on next page) board auto-...
Page 109
INSTALLATION INSTRUCTION 16(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 BTU-C (ROF 157 5111/_) Connection field 4 Not always mounted Connection field 4 and 6 Connection of (market-dependent) analogue telephone The index number PFa0 YELLOW refers to the individual...
Page 110
INSTALLATION INSTRUCTION 17(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 BTU-B (ROF 157 5121/_) BTU-B2 (ROF 157 5121/_) Applies for indices 1 and 3 Applies for indices 4 and 5 The BTU-B provides connection for up to 8 physical links and every physical link can be configured as a S- or T-interface in point-to-point or multi-point mode.
Page 111
INSTALLATION INSTRUCTION 18(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 receiver interface. Switches 3 and 4 enable remote Using the S/T Bus Interface Circuit eXtended (SBCX) power feeding to ISDN terminals connected to a link. up to13 dB line attenuation can be covered.
INSTALLATION INSTRUCTION 19(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 BTU-D (ROF 157 5112/1) and Connection field 6 REG (ROF 157 5112/2) The DIP-switch is shown with both contacts in OFF position S/T-Interface for connecting trunks and S-terminals Wall outlet connection...
Page 113
These DIP-switches connect the 75 Ω interface coax screen to ground, either directly to long standard cable is available with the ERICSSON ordering number TSR 901 0481/20000. 0V or via a 1 nF capacitor. DIP-switch 198 switches the receiver and 199 the transmitter side.
Page 115
INSTALLATION INSTRUCTION 22(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 5.10.1 Paging connection The figure shows how to connect the paging equipment Ericall Contactor with 2 wire speech. The PBX sends paging information to paging system (pin 6A18) using M1 contact, and information about ’paging in progress’...
Page 116
INSTALLATION INSTRUCTION 23(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 5.10.2 Four wire speech connection The four wire speech and signalling connection has the benefit of not needing additional signalling wires. There are two different types of signalling supported: Cailho E&M-signalling (balanced battery).
Page 117
INSTALLATION INSTRUCTION 24(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 5.10.3 E&M-signalling Signalling on E & M wires is done either using one or two E&M pairs depending on what is required. Using just E1 and M1 is a very common practice.
INSTALLATION INSTRUCTION 26(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 5.12 CPU-D4 (ROF 157 5124/_) Connections on the CPU-D4 Similar to the previous versions this board provides the V.24 interfaces but additionally the RS-485 interface for longer ranges.
INSTALLATION INSTRUCTION 27(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 wise data is lost if printer is OFF. The range of the in- 5.13 ELU-C (ROF 157 5115/1) terface is up to 1200m. Several converters may be used but with the following successful tests were accomplished: This board is used to connect the DBC 7xx series to...
INSTALLATION INSTRUCTION 28(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 5.14 ELU-A and ELU-D_ These terms and connections apply in connection The connection of extension boards described in this field 6 at front of an ELU-D(3) and ELU-A chapter are: •...
INSTALLATION INSTRUCTION 29(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 5.15 MFU (ROF 157 5132/_) Board disconnected RYS102 538/2 VMU,ELU-A/D yellow Line blocked green Line busy RYS102 538/1 COMPACT S41 is for S42 refer to next page FLASH...
Page 123
The MFU board can use only flash cards supplied by When selecting S- or T-interfaces start by setting the ERICSSON. These flash cards are delivered with a T-interfaces using switches 4, 3, 2 and 1 in consecutive control file called DISK.ULK containing a licence key.
INSTALLATION INSTRUCTION 31(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 5.16 VMU-HD (ROF 157 5126/_) 990/1 990/2 FUNCTION ON or To install unpack the VMU-HD board with the mounted 16 channels, no register function hard disk.
INSTALLATION INSTRUCTION 32(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 INTEGRATED CORDLESS The board offers the following connections: • the Cordless System Manager (on a PC) The Integrated Cordless (IC) is a digital cordless tele- •...
INSTALLATION INSTRUCTION 33(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 feeding Pairs (EPP) need to be wired. The maximum wire length between BS (fed locally) and IC-LU is only data lim- ited and may reach up to 1900 meters.
Page 127
INSTALLATION INSTRUCTION 34(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Minutes mErlang Minutes mErlang per hour per hour Example: A customer ordering a system with 55 portable telephones estimates that each portable generates 200 mE traffic in average.
INSTALLATION INSTRUCTION 39(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Base Station ( KRCNB 201 03/_ KRCNB 301 03/_ The Base Station (BS) enables radio communication between the Integrated Cordless system and the portable telephones.
Page 133
INSTALLATION INSTRUCTION 40(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Ground floor corridor intermediate floor Base Station 1 3,5m e.g. 40m 6.7.2 Base Stations Cabling Using a four-pair cable or more-pair cable, the free cable pairs can be used as additional power wires (EPP) to increase the feeding distance and reduce overall power consumption (by reducing the ohmic resistance) to the BS.
Page 134
INSTALLATION INSTRUCTION 41(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 6.7.3 Base station cable delay measurement After all base stations have been installed, the cable delays must be measured in order to program the base station delays into the system at initialization time.
Page 135
INSTALLATION INSTRUCTION 42(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 6.7.5 Base Station (KRC NB 203 01/_) The Base Station (BS) is supplied with a drilling template to mount the unit and 2 antennas with TNC connectors. Mount the unit in a suitable location to provide the best communication coverage.
Page 137
INSTALLATION INSTRUCTION 44(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Fixing the mounting bracket to a wall Fix the mounting bracket (see figure below) to the wall as follows: Hold the mounting bracket with its flat side against the wall such that the text ‘TOP’...
Page 138
INSTALLATION INSTRUCTION 45(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Cable ducts When the BS is mounted to the wall, cable ducts can be used to route the wiring through. •...
EURO-connectors for 4 wire-pairs • In those cases where a separate ERICSSON MDF has been installed, prefabricated cables are used between the MDF and board connectors in the exchange cabinet. These cables have EURO-connectors mounted at one end for connection to the board To connect the ELU-A, ELU-D, MFU, BTU-A, BTU-C and BTU-E to MDF, use cable: •...
Page 140
Cable with 8 pairs, mounted with: TSR BS 902 0001/800 800 mm standard cable for integrated MDF ERICSSON plug and Krone bar. /1500 1500 mm standard cable for external MDF 3000 mm MDF cable for existing MDF /3000...
Page 141
A & B ind. 5(10) ind. 1 ind. 2 ind. 10 part number usege RPM 603 337/1 1500mm standard cable for ERICSSON MDF length a part number usege 383 718/3 3000mm standard cable for ERICSSON MDF RPM 603 310/15000 15000mm...
Page 142
INSTALLATION INSTRUCTION 49(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 7.1.3 Coax cable for BTU-D length a part number usege coax cable 75 Ω for BTU-D TSR 225 1304/20000 20000mm 7.1.4 V.24 cables...
Page 143
INSTALLATION INSTRUCTION 50(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 7.1.5 Exchange power cables length a part number usege TRE 990 113/850 850mm exchange power cable TRE 990 113/1500 1500mm exchange power cable 7.1.6...
Page 144
INSTALLATION INSTRUCTION 51(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 7.1.7 Mains power cables Cable for EUROPE length a part number usege RPM 945 323 2500mm mains power cable 230V 10A Cable for Brazil, Mexico, Venezuela etc.
Page 145
INSTALLATION INSTRUCTION 52(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 Cable for Australia, New Zealand, China etc. length a part number usege RPM 945 311 2500mm mains power cable 250VAC 10A Cable for Italy, Chile length a part number...
INSTALLATION INSTRUCTION 53(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 MARKING OF CABLES INSTALLATION OF MDF (Main Distribution Frame) Each cable that is connected to a PBX type ASB 150 should be marked on the cable’s designation holder with the label set SVH 277 003/4, supplied for this Integrated MDF SXK 106 4208/1 purpose.
INSTALLATION INSTRUCTION 54(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 External MDF SXK 106 4139/1 Line network Unpack the MDF cabinet and remove its front cover. Place the cables according to the figure. Mount the MDF cabinet on its designated position.
BDV 113 31 (ERICSSON) Earth connection ELU-_ BTU-A BTU-_ alternative 1 with standard ERICSSON MDF connection bars TSR 902 0444/1 = 1.5 m TSR 252 0201/1600 (1600 mm) -/2 = 3.0 m alternative 2 open ends for any MDF TSR 901 0472/1 = 3.0 m -/2 = 15.0 m...
INSTALLATION INSTRUCTION 56(57) Prepared Subject responsible Documentnumber 1531-BDV 113 08 Uen Doc respons/Approved Checked Date File/Reference 1999-07-15 Door Interface Unit (DIU) sounds loud and clear enough other wise repeat the procedure. (BFY BS 10101/1) • No voice connection to the speaker of the telephone.Turn the mic potentiometer screw two Installation: turns clock wise.
INSTALLATION INSTRUCTION 57(57) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BDV 113 08 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 INSTALLATION OF ALARM INTERFACE UNIT Line to exchange DBY BS 410 01/1 nc ba bb nc line to exchange ba and bb are the connectors to the alarm button...
(2,1 A on 48V) of the power supply unit is not exceeded. The power supply unit is mounted within the cabinet BDV BS 101 05 and BDV BS 101 01. If initially an exchange with battery backup is ordered, the unit is preconfigured with a power supply with battery charger.The batteries are delivered separately and have to be installed according to this installation instruction.
A: Power switch does not disconnect the unit from mains. This switch only shuts down the unit to standby. B & C: are screws required for mounting the power Battery cable supply unit (screw (C) is only for BDV BS 101 01). connector (E) 6,3A T 250V D: this is the DC supply cable to the exchange.
Then remove the screw (B) at the top and turn the bottom screw (C) two turns counter clockwise (the screw (C) applies only in cabinet BDV BS 101 01). Push up the power...
(1537-ASB 150 02). The battery case is equipped with a fuse. This part has the ERICSSON ordering number NGH 258 03/ 630. This fuse is required to prevent a short circuit on the supply cables which might cause a fire.
CB = circuit breaker 6,3 A T / >150 A cutoff capability, should also function as a switch Changing the battery fuse The battery fuse is accessible from the front of the unit. Replace it only by a fuse with the ERICSSON ordering number NGH 258 03/630 Ask your local supplier for details.
INSTALLATION INSTRUCTION 7(8) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BML BS 101 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1999-07-15 ALARM CONNECTION For connection of the ALARM input to indicate that the system is running on battery power, use an ERICSON standard MDF Connector CPU-D I/O cable or if an MDF is already equipped use a cable with...
C13) must be right angular for the connection to the power supply unit and moulded to the cord. ACCESSORIES Fuse ERICSSON ordering number NGH 258 03/630. Batteries The batteries for this exchange must comply to: ERICSSON product No. BKC BS 101 01/1...
INSTALLATION INSTRUCTION 3(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 LOCATIONS BATTERY UNIT F1 F2 CIRCUIT BREAKER Figure 1 power supply with battery charger BML 351013/- The physical connections on the BML unit are listed B C D below, together with a simple explanation of their purpose.
Page 162
INSTALLATION INSTRUCTION 4(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 Make the connections in the battery cabinet according to the wiring diagram below, using the supplied cables. battery interconnection cables TRE 990 119/0200 battery terminal cable (grey)
INSTALLATION INSTRUCTION 5(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 INSTALLATION Installing the integrated battery unit BKB 201 001 If the system is already installed and operating, inform the customer that your Mount the integrated battery unit with its work is going to shut down his exchange.
INSTALLATION INSTRUCTION 6(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 48 V present in the system if the switch is Raise the bottom plate, replace the front turned on. Continue with 5.3 or 5.4. cover and tighten the two screws at the bottom of the front cover.
INSTALLATION INSTRUCTION 7(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 REPLACING THE BML UNIT Note that as soon as the cable is plugged in (A) and the circuit breaker is on, the -48 V are present in the system.
INSTALLATION INSTRUCTION 8(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 BATTERY REPLACEMENT Replacing batteries in the battery cabinet BKB 201 002. Battery replacement should be done while the system is in operation and running on mains.
INSTALLATION INSTRUCTION 9(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 ALARM CONNECTION ASB 150 01 The ALARM feature cannot be used in ASB 150 01. MDF Connector CPU-D CPU-D/2 ASB 150 02 Prerequisites: In order to install the alarm feature, the CPU-D (ROF 157 5118/1) must have revision R1A/A...
Page 168
BKB 201 001 can be ordered separately, but the whole lot should be replaced at the same time. For replacement, we recommend the batteries should be purchased from ERICSSON, as they are a HIGH-quality LONG-life type that is not commonly available.
Page 169
INSTALLATION INSTRUCTION 11(12) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 BATTERY BACK UP So charge them again as soon as possible after the power failure. If the batteries are completely discharged and it is not possible to charge them, turn For the BusinessPhone 250 there are 2 different types off the circuit breaker on the battery unit to prevent...
Page 170
Installation instruction 12(12) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BML 351 013 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 98-11-20 BKB 201 002 This larger battery back up unit housed in a separate cabinet with batteries rated with 15Ah has the charger BML 351 013/x mounted at the rear of the cabinet.
INSTALLATION INSTRUCTION 3(10) Dokumentnr/Documentnr Uppgjord/Prepared Faktaansvarig - Subject responsible 1531-BML 351 048 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1998-05-29 LOCATIONS 4.0.1 Power Supply PSU 75 with battery charger (BML 351 048) The switched mode power supply is available for applications demanding a higher current than supplied by the trans- former and/or a battery backup for the PBX is required.
INSTALLATION INSTRUCTION 5(10) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 048 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1998-05-29 Make the connections in the battery cabinet according INSTALLATION to the wiring diagram below, using the supplied cables. If the system is already installed and operating, inform the customer that your work is going to shut down his exchange.
INSTALLATION INSTRUCTION 7(10) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 048 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1998-05-29 REPLACING THE BML UNIT Note that as soon as the cable is plugged in (A) and the circuit breaker is ON, the -48 V are present in the system.
INSTALLATION INSTRUCTION 8(10) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 048 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1998-05-29 BATTERY REPLACEMENT Replacing batteries in the battery cabinet BKB 201 002. Battery replacement should be done while the system is in operation and running on mains.
INSTALLATION INSTRUCTION 9(10) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-BML 351 048 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1998-05-29 ALARM CONNECTION ASB 150 01 The ALARM feature cannot be used in ASB 150 01. MDF Connector CPU-D CPU-D/_ ASB 150 02 Prerequisites: In order to install the alarm feature, the CPU-D (ROF 157 5118/1) must have revision R1A/A...
Page 180
BKB 201 001 can be ordered separately, but the whole lot should be replaced at the same time. For replacement, we recommend the batteries should be purchased from ERICSSON, as they are a HIGH-quality LONG-life type that is not commonly available.
INSTALLATION INSTRUCTION 2(6) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-RPM 603 339 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1993-11-09 GENERAL This document describes how to install the water proof temperature sensor(s) RPM 603 339. The temperature sensor(s) may be situated outdoor to measure the outdoor temperature.
INSTALLATION INSTRUCTION 3(6) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-RPM 603 339 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1993-11-09 These components are necessary to get the FUNCTIONALITY temperature function: The temperature is displayed on the digital phones • AUX board ROF 157 5119 or/and CPU-D board with display.
Page 184
INSTALLATION INSTRUCTION 4(6) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-RPM 603 339 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1993-11-09 HARDWARE If the sensor is to be placed outside it is preferably mounted on a wall outside, with the attached screw, INSTALLATION that is not placed in direct sunlight.
INSTALLATION INSTRUCTION 5(6) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1531-RPM 603 339 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1993-11-09 FUNCTION VERIFICATION ASB 150 01 Verify on a digital telephone with display that the tem- perature indication correspond with actual tempera- ture.
Page 188
A B C recorder to a1, b1 on the connector block of the input Ericsson standard MDF cable TSR 902 0444/1. The Ericsson standard MDF cable will carry all CPU-D/1 AUX/1 connections of the CPU-D, CPU-E and AUX options, to the MDF.
Page 189
INSTALLATION INSTRUCTION 3(3) Uppgjord/Prepared Faktaansvarig - Subject responsible Dokumentnr/Documentnr 1/1531-ASB 150 02 Uen Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Datum/Date Tillhör/Referens-File/Reference 1993-11-15 PROGRAMMING Programming of this feature is done with the aid of the support system RASC. Please consult the document START OF OPERATION (1537-ASB 150 02) or use the RASC system directly...
Page 190
1(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) EBC/EN/DMTL Thomas Åsberg 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File EN/DMTL (Sture Winther) 1997-06-18 Telephone sets (DBC 210 01and DBY 410 02) General .
Page 191
The digital telephone sets (DTS) and peripherals described in these installation instructions are to be used together with the Ericsson exchanges ASB 501, ASB 150 02 or equivalent. The DTS is connected to a digital extension board, ELU 28, or equivalent.
Page 192
3(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Cabling Maximum line length between DTS and extension line unit (ELU) using EKKX 0,5 mm (180 ohms/km) cable: 1000 m (3280 ft): Installation of DTS Delivery method...
Page 193
4(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Connection to the extension line The line cord shall be connected in one end to the wall box according to fig 7-1 and the other end to the connector in the bottom of the set marked LINE.
Page 194
5(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Figure: 7-3. Mounting of hook Position for hook: Wall mounting Post installation measures...
Page 195
6(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Figure: 8-1. Rear view of DTS with DBY 410 02 connectors. DBC 210 01 Programming of option unit functions To program the option unit functions, OPTION UNIT FUNCTION MODE must be selected by...
Page 196
7(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Figure: 8-2. Option unit function mode settings LED 4 LED 5 LED 6...
Page 197
8(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Extra bell / busy signal There are two alternatives using this function.
Page 198
9(9) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531- DBC 210 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-06-18 Connection of tape recorder A tape recorder can be connected for recording of calls. The recorder can be connected either to jack J3 fig 8-1 or jack J4 fig 8-1.
Page 199
1(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. EBC/EN/DMTL Jonas Pettersson 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File EBC/EN/DMTL (Sture Winther) 1998-04-20 Telephone sets (DBC 211 01, DBC 212 01, DBC 213 01, DBY 409 01 or DBY 409 02 and DBY 410 02)
Page 200
The digital telephone sets (DTS) and peripherals described in these installation instructions are to be used together with the Ericsson exchanges ASB 501, ASB 150 02 or equivalent. The DTS is connected to a digital extension board, ELU 28, or equivalent.
Page 201
3(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Cabling Maximum line length between DTS and extension line unit (ELU) using EKKX 0,5 mm (180 ohms/km) cable: 1000 m (3280 ft): Installation of DTS Delivery method...
Page 202
4(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Connection to the extension line The line cord shall be connected in one end to the wall box according to fig 7-1 and the other end to the connector in the bottom of the set marked LINE.
Page 203
5(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Mounting of hook Position for hook: Wall mounting Post installation measures Verify that a call can be established from and to the DTS.
Page 204
6(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 If a second DBY 409 01 is to be installed, do as follows •...
Page 205
7(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Snap the enclosed foot console to the last DBY 409 02 installed Remove the blinder covering the contact J9 Connect the power supply unit (RES 141 305/2 or equal) to the DBY 409 02 closest to the DBC 213 01 and then to the mains.
Page 206
8(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Note: When using DBY 410 02 the handset connector on the DTS will be disabled. With the DBY 410 02 mounted, the telephone cannot be wall mounted without extra measures.
Page 207
9(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Option unit function mode settings LED 4 LED 5 LED 6...
Page 208
10(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Extra bell / busy signal There are two alternatives using this function.
Page 209
11(11) INSTALLATION INSTRUCTIONS Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No. 1531- DBC 211 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1998-04-20 Connection of tape recorder A tape recorder can be connected for recording of calls. The recorder can be connected either to jack J3 fig 9-1or jack J4 fig 9-1.
Page 210
1(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) EBC/EN/DMTL Thomas Åsberg 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File EBC/EN/DMTL (Sture Winther) 1997-11-19 Operator’s console (DBC 214 01, DBY 409 01 or DBY 409 02 and DBY 410 02) General .
Page 211
Scope The digital operator’s instrument (OPI) and peripherals described in these installation instructions are to be used together with the Ericsson exchanges ASB 150 02 or equivalent. The OPI is connected to a digital extension board, ELU-D_ or equivalent. Environmental requirements The products covered in these installation instructions comply with the prerequisites stipulated for placing in office and exchange room environments.
Page 212
3(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Cabling Maximum line length between OPI and extension line unit (ELU) using EKKX 0,5 mm (180 ohms/km) cable: 1000 m (3280 ft).
Page 213
4(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Connection to the extension line The line cord shall be connected in one end to the wall box according to fig 7-1 and the other end to the connector in the bottom of the set marked LINE.
Page 214
5(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Mounting of hook Position for hook: Wall mounting Post installation measures Verify that a call can be established from and to the OPI.
Page 215
6(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 If a second DBY 409 01 is to be installed, do as follows •...
Page 216
7(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Rear view of DBC 214 01 with two DBY 409 02 connected. Power supply unit MAINS OPI type...
Page 217
8(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 With the DBY 410 02 mounted, the OPI shall be wall mounted using extra spacers, with a thickness >...
Page 218
9(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Option unit function mode settings LED 4 LED 5 LED 6 LED 8 LED 7...
Page 219
10(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Extra bell / busy signal There are two alternatives using this function. The function is selected by means of LED 8. Extra bell: Active when the OPI receives a ring signal.
Page 220
11(11) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 1531-DBC 214 01 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1997-11-19 Connection of tape recorder A tape recorder can be connected for recording of calls. The recorder can be connected either to jack J3 fig 9-1or jack J4 fig 9-1.
Page 221
1(5) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) EBC/FMD/TL Thomas Åsberg 47/1531-APD 101 02 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File EBC/FMD/TL (Thomas Åsberg) 1996-04-10 TAU D Contents .
Data Terminal Equipment (DTE) that wants to access to the proprietary signal channel in the Ericsson exchanges ASB 501, ASB 150 or equivalent. It can operate in stand alone mode or share the extension line with a digital system telephone. It can share the telephone line with digital system telephones (DTS) of the DBC 600, DBC 200 families or equivalent.
3(5) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 47/1531-APD 101 02 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1996-04-10 Technical data Power consumption: maximum 1.0 W Environmental requirements TAU D complies with the prerequisites stipulated for placing in office and exchange room environments.
4(5) INSTALLATION INSTRUCTIONS Uppgjord - Prepared Nr - No. (även faktaansvarig om annan) (also subject responsible if other) 47/1531-APD 101 02 Uen Dokansv/Godkänd - Doc respons/Approved Kontr - Checked Datum - Date File 1996-04-10 Power equipment The TAU D is powered from the Extension line. Earthing The TAU D needs no special earthing.