Besantek BST-MG08 Manual Instruction

Multi-gas detecting alarm

Advertisement

Quick Links

BST-MG08/09 Multi-gas Detecting Alarm

Application

1.
: This product is designed to ensure safety for users who work in dangerous
places. It's used for detecting CO, O2, H2S, CH4 simultaneously and alarm users by light,
sound and vibration. This device is portable, anti-explosion and intrinsically safe.

Features

2.
:
1. Measured gases: Combustible Gas(LEL/CH4), Oxygen(O2), Carbon Monoxide(CO), and
Hydrogen Sulfide(H2S). Contact manufacturer for other gas combinations.
2. It will alarm users by sound, vibration, and light with different intensity if actual
concentration is higher or lower than preset alarm points.

Operation

3.
:
1. 4 buttons included.
2. Long press
On/Off button to activate the device. It will show below information in
turn:
A. Product brand
B. Low Alarm [L]
C. High Alarm [H]
D. STEL Alarm [S]
E. TWA Alarm [T]
F.
Preset Calibration Value
G. Product number and next calibrate date, 30 seconds countdown
H. Auto Zero option
LOGO
3. In auto zero option, after seeing "Adjust Zero?", long press "OK" button to zero all
sensors, short press "
system will zero itself when the device is back to fresh air, no need to worry about the
accuracy.
4. In main interface, it shows 4 alarm icons on top area: [L], [H], [S], [T], if there is any alarm,
the corresponding icon will turn red. Short press "▲" to switch among STEL, TWA, PEAK,
and MIN. No operation for 30 seconds will bring it back to main interface.
5. Long press "OK" button to enter function interface.
Manual Instruction
On/Off button; OK button; ▲Up button; ▼Down button
Main Interface
" button to exit. When the device is zeroed in unfresh air, the

Function interface

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BST-MG08 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Besantek BST-MG08

  • Page 1 BST-MG08/09 Multi-gas Detecting Alarm Manual Instruction Application : This product is designed to ensure safety for users who work in dangerous places. It’s used for detecting CO, O2, H2S, CH4 simultaneously and alarm users by light, sound and vibration. This device is portable, anti-explosion and intrinsically safe.
  • Page 2 6. In function interface, short press “▲” or “▼” to select function, then short press “OK” button to enter corresponding function. 7. In zero interface, short press “ ▲ ” or “ ▼ ” to select gas, long press “OK” button, the background of selected gas will turn red, long press “OK”...
  • Page 3 Important: user should make this setting before following operations. B. In “Common Calibration” interface, short press “▲” or “▼” to select gas, long press “OK” button, the background of selected gas will turn red, connect calibration gas and after the value is stable, long press “OK” button to complete this operation with display of “Set OK”.
  • Page 4 (>100~500)ppm: True Value±5% (>500~1000)ppm:True value±6% Respond time ≤45s (T90) Resolution 1ppm Alarm point 24%vol(Adjustable for full range) Hydrogen Sulfide (H2S) Measurement range (0~100)ppm Measurement error (0~50)ppm:±3ppm (>50~100)ppm: ±10% Respond time ≤45s (T90) Resolution 1ppm Alarm point 10ppm(Adjustable for full range) Sensor lifetime CH4: ≥1 year CO,H2S,O2: ≥2 years...
  • Page 5 External Sampling Pump Manual Instruction Product description: This gas sampling pump can be used with any portable gas detectors, and detect target gas as far as 30 meters. With 4 LED indicators, user can know power left easily. Technical parameter: 1600ml/min Sampling Air Flow Sampling Distance...
  • Page 6 Gas Check User’s Guide 1. Gas Detector Data Collection Setting 1.1. Activate gas detector by long pressing button. 1.2. Long press OK button to function interface 1.3. Press up/down button and choose “Setting”, enter it by short pressing OK button 1.4.
  • Page 7 3.3. After connection, date and time on gas detector will synchronize automatically with computer. “Real-time” is for collecting real-time data, these data will only store on computer, check&analyze these data on “Data show” section “Real-time data”. “History data” is for checking data collected by gas detector or data have been stored on computer A.
  • Page 8 “History data” is for data collected by gas detector and data have been stored on computer. “Select device” to see available history data of a certain gas detector. “DEL” is to delete just model number of gas detectors which have been registered on this computer, this function is for a better management of more than one gas detector you use.

This manual is also suitable for:

Bst-mg09

Table of Contents