Do not use corrosive or flammable gases or liquid with this product.
1
Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure,
2
permanent damage to the pressure sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may
3
be broken and can cause malfunction.
Turn power off before connecting wiring. Incorrect wiring or short circuit will damage and / or cause malfunction.
4
Do not use in environment where steam or oil vapor is present.
5
This product is not explosion-proof rated. Do not use in atmospheres containing flammable or explosive gases.
6
Avoid wiring the sensor cable adjacent to or in the same cable tray with power or high voltage lines. Doing so
7
could cause malfunction due to noise.
This product is not a safety sensor. Its use is not intended to protect life and prevent bodily injury or property
8
damage from dangerous parts or machinery. It is a normal object detection sensor.
SPECIFICATIONS
Rated pressure range
Operating / Set pressure range
Maximum pressure
(Exceeding max pressure could damage switch)
Fluid
Set pressure
resolution
Power supply voltage
Current consumption
Switch output
Repeatability (Switch output)
Hysteresis mode
Window comparator mode
Response time
Output short circuit protection
7 segment LCD display
Indicator accuracy
Switch ON Indicator
Environment
Temperature characteristic
Port size
Lead wire
青岛秉诚自动化设备有限公司
地址:中国·青岛市重庆南路99号海尔云街甲3号楼7F
Weight
-100 ~ 1000 kPa
- 14.5 PSIG ~ + 145 PSIG
kPa
kgf/cm
2
bar
psi
InHg
mmHg
PNP open collector
Max. load current: 125mA
Max. supply voltage: 24VDC
Residual voltage: 1.5V
(load current 125mA)
≤ 2.5ms (chatter-proof function: 24ms, 250ms, 500ms, 1000ms and
Two color (red/green) display (sampling rate: 5 times/1sec.)
≤ ± 2.0 % F.S. ± 1 digit (ambient temp: 77°F ± 5°F / 25°C ± 3°C)
Enclosure
Operation: 0°F ~ 122°F / 0°C ~ 50°C, Storage: 14°F ~ 140°F / -10°C ~
Ambient temp. range
Ambient humidity range
Withstand voltage
Insulation resistance
50Mohm min. (at 500 VDC, between case and lead wire)
Vibration
Shock
1/8 NPT Male x 10-32 UNF Female, 1/8 PT x M5, G 1/8 x M5
服务热线:4006-918-365
网址:http://www.ivalve.cc
DPS280 / DVS280 Series
DPS280
(PRESSURE)
0 ~ 1000 kPa
0.0 ~ - 101.3 kPa
0 ~ 145 PSIG
0 ~ 29.9" Hg Vacuum
10.0 ~ - 101.3 kPa
1.45 PSIG ~ 29.9" Hg Vacuum
1500 kPa
217.5 PSIG
Air, Non-corrosive gases, incombustible gases
1
0.01
0.01
0.1
-
-
12 to 24VDC ± 10 %, Ripple (P-P) 10 % or less
≤ 45mA (with no load)
NPN open collector
Max. load current: 125mA
Max. supply voltage: 30VDC
Residual voltage: 1.5V
(load current 125mA)
≤ ± 0.2 % F.S. ± 1 digit
Adjustable
1500ms selections)
Yes
Green OUT Indicator
IP40
60°C
(no condensation or freezing)
Operation/Storage: 35 ~ 85% RH (no condensation)
1000VAC in 1-min (between case and lead wire)
Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for
1 minute, two hours each direction of X,Y and Z
100m/s
2
(10G), 3 times each in direction of X,Y and Z
≤ ± 2% F.S. of detected pressure (77°F / 25°C) at temp.
Range of 0°F ~ 122°F / 0°C ~ 50°C
Oil-resistant cable (0.15 mm
传真:(86-532)585-10-365
Approx 45g - Switch only
Email:sales@ivalve.cc
Approx 90g - Switch with 2M mating cable
DVS280
(VACUUM)
300 kPa
43.5 PSIG
0.1
0.001
0.001
0.01
0.1
1
2
)
DPS280 / DVS280 Series
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPS280 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Numatics DPS280 Series

  • Page 1 DPS280 / DVS280 Series Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage to the pressure sensor may occur. Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can cause malfunction.
  • Page 2: Panel Instructions

    OUTPUT CIRCUIT WIRING HOW TO ORDER DPS 280P N Q8 PNP output Electrical Connection Type DC (+)(Brown) Q8 = 8mm Pico Quick Connect DPS = Digital Pressure Switch 4 Pin w/ 2M Mating Cable DVS = Digital Vacuum Switch Port Type OUT (Black) Output Type N = 1/8 NPT Male X 10-32 F...
  • Page 3: Mounting Bracket Kits

    DIMENSIONS 7/16¨ (11.0) 1.18 (30.0) 0.79 (20.0) 0.39 (10.0) M3 x 0.5 THD 2 PLS 1.18 0.39 (30.0) (10.0) 0.79 (20.0) 0.46 (25.4) (11.8) 1.26¨ 5.9±0.4 (32) (150±10) 0.28¨ 0.35¨ 1.18 (30.0) 78.75¨ (2000 mm) M8 Female 4 Pin Mating Cable Supplied With Switch Mating Cable: Cable O.D.
  • Page 4: Setting Steps

    SETTING STEPS Sensing Mode Initial Setting Pressure Setting Zero Calibration Sensing Mode Units P_1 or n_1 Calibrate switch to zero under Display Color P_2 or n_2 atmospheric conditions Operation Mode Output Type Response Time Manual / Auto Setting INITIAL SETTING MODE Sensing Mode To enter initial setting mode press and hold button for 3 seconds.
  • Page 5: Manual Setting Mode

    PRESSURE SETTING MODES Select auto / manual setting mode during initial set-up. To enter pressure setting mode, momentarily press button from sensing mode. Manual Setting Mode Use when desired Pressure and Hysteresis values are known by operator. Sensing Mode Sensing Mode Alternating Display Alternating Display Alternating Display...
  • Page 6: Output Type

    ZERO CALIBRATION / THE MAX. & MIN. DISPLAY MODE Zero Calibration: Calibrate switch to zero under atmospheric conditions. Press the buttons at the same time until the “00” is shown. Release the buttons to end zero calibration. Maximum Applied Pressure Display: Press and hold button 2 seconds to enter the maximum value display mode.

This manual is also suitable for:

Dvs280 seriesDps280pnq8

Table of Contents