ZIEHL MU100U Operating Manual

Universal transmitter / isolation amplifier

Advertisement

Quick Links

Temperature Relays and MINIKA®
Operating Manual MU100U
- Universal Transmitter / Isolation Amplifier
MU100U
10730-0701-00
Mains Monitoring
Digital Panelmeters MINIPAN®
Switching Relays and Controls
Page 1 / 8
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstr.13, 74523 Schwäbisch Hall, Germany
+ 49 791 504-0,
info@ziehl.de,
Measuring Transducers
Grid- and Plant Protection
updated: 2018-11-09 / sm
www.ziehl.de
www.ziehl.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MU100U and is the answer not in the manual?

Questions and answers

Summary of Contents for ZIEHL MU100U

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection updated: 2018-11-09 / sm...
  • Page 2: Table Of Contents

    Adjustment examples..........................5 10 Error search ............................6 11 Technical data ............................6 12 Housing Type K ............................8 1 Display and controls Adjust Full- scale Adjust Zero LED green - in Operation MU100U 10730-0701-00 Page 2 / 8 www.ziehl.de...
  • Page 3: Application And Short Description

    The universal transmitter MU100U can be connected to any supply voltage between 24 V and 240 V, DC or AC voltage can be connected. Input and output signals are galvanically isolated. Signals DC 0/4-20 mA or 0-0 V can be connected to the inputs.
  • Page 4: Important Information

    A circuit-breaker or switch must be situated within easy reach of the unit and fused. Installation excess current protection should be ≤ 10 A. MU100U 10730-0701-00 Page 4 / 8 www.ziehl.de...
  • Page 5: Connection Examples

    2) Input Output 0…20 mA or 0…10 V Zero point: at the input (terminals 1 and 2) set current constant to 4.800 mA. Adjust the current or voltage output with the potentiometer “Zero”. MU100U 10730-0701-00 Page 5 / 8 www.ziehl.de...
  • Page 6: Error Search

    0,025% *K Nominal rise time t= 0,9 50 ms Test conditions EN 61010-1 / EN 50178 Rated impulse voltage 4000 V Overvoltage category Pollution degree Rated insulation voltage Ui 300 V On-period 100 % MU100U 10730-0701-00 Page 6 / 8 www.ziehl.de...
  • Page 7 Protection class housing / terminals IP40 / IP 20 Snap mounting on 35 mm standard rail EN60715 or Mounting M4 screws (additional bar not included) Mounting position Various Weight app. 200 g Subject to technical changes MU100U 10730-0701-00 Page 7 / 8 www.ziehl.de...
  • Page 8: Housing Type K

    12 Housing Type K Dimension in mm 22,5 110,0 100,5 lower part upper part screw holes for screw mount MU100U 10730-0701-00 Page 8 / 8 www.ziehl.de...