SUPERCOOL 1000
Temperature Controller
M 890-00039 rev.03
User's manual
1000
RUNNING
PUMP
MAINTENANCE REQUIRED
CURRENT
C
CONDITIONS
MISTING
MISTING
DRAINING
MISTING FOR DUST CONTROL
1
MISTING
MIST SHUT OFF HIGH RH
MIST SHUT OFF NIGHTIME
RH COMPENSATION ACTIVE
2
FAN GROUP 1
ACTIVE
FAN GROUP 1
3
FAN GROUP 2
ACTIVE
FAN GROUP 2
4
FAN GROUP 3
ACTIVE
FAN GROUP 3
ALARM
5
SETTINGS
ALARMS
TEMPERATURE
RH COMPENSATION
6
DEFECTIVE PROBE
& DUST CONTROL
WATER SPILL
NO WATER
LOW WATER PRESSURE
7
TIME & DATE
MODIFY
8
WATER USAGE MONITORING
9
PUMP RUN TIME
10
PUMP MAINTENANCE
11
INSTALLATION
12
TEST MODE
N/A
N/A
MISTING - MANUAL MODE
REV. 00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPERCOOL-1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Secco SUPERCOOL-1000

  • Page 1 SUPERCOOL 1000 Temperature Controller User’s manual MODIFY 1000 RUNNING PUMP MAINTENANCE REQUIRED CURRENT WATER USAGE MONITORING CONDITIONS MISTING MISTING DRAINING MISTING FOR DUST CONTROL MISTING PUMP RUN TIME MIST SHUT OFF HIGH RH MIST SHUT OFF NIGHTIME RH COMPENSATION ACTIVE FAN GROUP 1 PUMP MAINTENANCE ACTIVE...
  • Page 2 Every effort has been made to ensure that this manual is complete, accurate and up- to-date. The information contained in it is however subject to change without notice due to further developments. SUPERCOOL-1000 rev.03...
  • Page 3: Table Of Contents

    Frequency ...... 12 6.5. Water Usage ....... 12 USER SETUP ....... 13 FAN GROUPS ......16 8.1. Principle of Operation ....16 8.2. Fan Group Parameters ....17 8.2.1. Temperature-Based Fans ..17 8.2.2. Humidity-Based Fans ....17 SUPERCOOL-1000 rev.03...
  • Page 4: Introduction

    If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Model: SUPERCOOL-1000 Do not spray water on the controller! In Serial number: order to clean the control, wipe it with a damp cloth.
  • Page 5: Features

    Probe Readings Recorded For Past Days — Minimum and maximum readings from tem- perature and humidity probes are recorded for The SUPERCOOL-1000 is an electronic device the current day and the past six days. used to control the humidity level and room temperature in livestock buildings.
  • Page 6: Location Of The Controls

    These keys are also used to change a parameter's value once the MODIFY key has been pressed. SUPERCOOL-1000 rev.03...
  • Page 7: Installation

    L and N electric power lines. It shall be in close proximity to the equipment and within easy reach of the operator. It shall be marked as the disconnecting device for the equipment. SUPERCOOL-1000 rev.03...
  • Page 8: Time & Date

    6 days. Press on the navigation down-arrow key again to display the current reading of the temperature probes. 1: 84.5 2: 84.0 3: 84.0 4: 83.5 SUPERCOOL-1000 rev.03...
  • Page 9: Individual Probe History

    Probe 1 12/04/XX Max 86.0 4:28P Press on the navigation down-arrow key to scroll the display. The minimum and maximum readings of all individual probes are displayed for the current day and for the past 6 days. SUPERCOOL-1000 rev.03...
  • Page 10: Humidity Sensor History For The Outputs

    3. 60 RH 1 12/07/XX Max 60 4:28P Press on the navigation down-arrow key to scroll the display. The minimum and maximum readings of all individual probes for the current day and for the past 6 days are displayed. SUPERCOOL-1000 rev.03...
  • Page 11: Stress Index

    6 days are Press - PUMP RUN TIME. displayed. Maintenance done? The message “Maintenance done?” is displayed on screen. Select “Yes” if the maintenance has been done. SUPERCOOL-1000 rev.03...
  • Page 12: Total Run Time & Reminder Message Frequency

    *Available if a water meter has been enabled in the Installation menu (see User Setup). Press the down-arrow key and scroll the display. The water consumption for the previ- ous six days is displayed. 12/07/xx 27lit 12/06/xx 32lit SUPERCOOL-1000 rev.03...
  • Page 13: User Setup

    *Available if at least one humidity probe is Relative Humidity (RH) Probe — Select the assigned to the mist output above. number of humidity sensors in use. Adjust- able from 0 to 3 sensors. Use dust con- trol ? #RH Probes SUPERCOOL-1000 rev.03...
  • Page 14 Night starts at the selected fan group when the temperature 6:00P is too high (critical T°) or to stop it when the temperature is too low (minimum T°), without Day starts at considering the humidity level. 7:00A SUPERCOOL-1000 rev.03...
  • Page 15 Adjustable from 0 to the next number. Use the arrow keys to enter 60 seconds. the second number, etc. Draining time Program Version Number — The program 15sec version of your controller is displayed. SUPERCOOL-1000 rev.03...
  • Page 16: Fan Groups

    This protection feature does not take into account the humidity level in the room. SUPERCOOL-1000 rev.03...
  • Page 17: Fan Group Parameters

    Adjustable from 0.5 °F (0.3 °C) above the minimum temperature to 120 °F (48.9 °C). Critical T° 80.0°F SUPERCOOL-1000 rev.03...
  • Page 18: Mist

    Press the down-arrow key and adjust the Timer 3 On temperatures and timer values for timers 2, Timer 3 Off 3 and 4. Timer 2 On Start 2 77.0°F Timer 2 Off Stop 2 76.0°F Timer 1 On Timer 1 Off Average T° SUPERCOOL-1000 rev.03...
  • Page 19: Typical Application

    SUPERCOOL-1000 9.3. Typical Application Manual Drain Valve Nozzles Drain Valve Mist Valve Water's entry Pump Pressure point Water Switch Meter Filters SUPERCOOL-1000 rev.03...
  • Page 20: Humidity Compensation

    5 seconds. If the compensation RH Level requires that the On Time value be less than Compensation Compensation 5 seconds, the On Time is set to 0 seconds from 80% RH to 90% RH and the mist units come to a stop. SUPERCOOL-1000 rev.03...
  • Page 21: Compensation Adjustments

    Adjust it to the desired value using the adjustment keys. Press MODIFY. The humidity level at which mist cycles operate using the minimum time on value flashes on the display. Adjust it to the desired value using the adjustment SUPERCOOL-1000 rev.03...
  • Page 22: Dust Control

    CLOSES BEFORE TRIPPING THE BY- OFFtime: 1:00m:s PASS SWITCH! Press the down-arrow key. The security temperature is displayed. The dust control stops being effective if the room temperature decreases below this limit. Security tempe- rature 60.0°F Bypass Switch SUPERCOOL-1000 rev.03...
  • Page 23: Test Mode

    *This parameter is only displayed if the test mode is enabled above and if at least one humidity sensor is enabled in the installation menu (see User Setup chapter). Humidity bypass SUPERCOOL-1000 rev.03...
  • Page 24: Alarm Settings

    Dashes are displayed instead of a reading when the Use the adjustment keys to adjust the probe is defective. high and low alarm limits. Avg RH: Probes: 123 1: 50 2: 52 3: ---- SUPERCOOL-1000 rev.03...
  • Page 25: Water Shortage

    Press the down-arrow key. The time in- terval corresponding to the minimum water quantity is displayed. It ranges from 1 to 10 minutes. Delay for min. flow : 2min Use the adjustment keys to adjust the time interval to the desired value. SUPERCOOL-1000 rev.03...
  • Page 26: Low Water Pressure

    3, the alarm will set off at the running must be defined by the user. 3rd pressure drop (on condition the pressure re-established itself between each drop). Nb.of try before alarm : SUPERCOOL-1000 rev.03...
  • Page 27: Technical Specifications

    F20-5A slow blow. Pump : ON-OFF Output, 115/230 VAC, 50/60 Hz, 5A, fusible F18-5A slow blow Enclosure: ABS, moisture and dust-tight. The room temperature where the controller is located must always remain between 32° and 104°F (0° and 40°C). SUPERCOOL-1000 rev.03...
  • Page 28: Memory Card

    To save the controller's configuration into the memory card, select the "Save Config" menu using the ADJUSTMENT buttons. Once this menu is selected, simultaneously press the ADJUSTMENT buttons' up- and down-arrow keys to start the transfer. Save config. Press SUPERCOOL-1000 rev.03...
  • Page 29 Do not move or hold the card Lock the card’s switch if required. while a transfer is ongoing. Remove the memory card from the con- nector when the transfer is over! SUPERCOOL-1000 rev.03...
  • Page 30: Installation Report

    SUPERCOOL-1000 INSTALLATION REPORT CLIENT Name: ______________________________________________ Address: ______________________________________________ ______________________________________________ ______________________________________________ City: ______________________________________________ Tel.: ______________________________________________ Fax: ______________________________________________ E-mail: ______________________________________________ INSTALLER Name: ______________________________________________ Address: ______________________________________________ ______________________________________________ ______________________________________________ City: ______________________________________________ Tel.: ______________________________________________ Fax: ______________________________________________ E-mail: ______________________________________________ SUPERCOOL-1000 rev.03...
  • Page 31 Use water pressure switch ? _____Yes _____No Pressure switch contact _____Normally closed (NC) _____Normally Open (NO) Drain valve delay _____ (0 to 60 seconds) ___1 ___2 ___3 ___4 ___5 ___6 Temperature display (probe selection) ___1 ___2 ___3 Humidity display (probe selection) Password SUPERCOOL-1000 rev.03...
  • Page 32: Index

    Day / night Mist shutoff in night Activation 14 Keys 6 Degrees Celsius / Fahrenheit degrees 13 Display 5 LCD display 6 LCD & LED display 6 Leds Room temperature Led display 6 Probe selection 15 Limits See Alarm limits SUPERCOOL-1000 rev.03...
  • Page 33 Adjusting a parameter 6 Symbols of the manual 4 Password Changing the password 15 Pressure switch Technical specifications 27 Activation 15 Temperature Location 19 Alarms 24 Probe Measurement units (°C/°F) 13 Connection 7 Outside temperature see Probes Extension 7 Room temperature SUPERCOOL-1000 rev.03...
  • Page 34 Selecting the time format 13 User setup 13–15 Ventilation see Fan groups Version Program version 15 Water meter Activation 15 Calibration 15 Location 19 Operation 12 Water pressure see Pressure switch Water shortage 25 Water spill 24 Wiring 7 SUPERCOOL-1000 rev.03...