Masibus HT16U User Manual
Masibus HT16U User Manual

Masibus HT16U User Manual

Humidity-temperature smartlogger

Advertisement

Quick Links

HT16U HUMIDITY-TEMPERATURE
DOC m94B-OM-101Issue No.
Customer Support: support@masibus.com Toll Free Number (India Only): 1 – 800 – ADD – CARE
Operator's manual
Page 1 of 16
User Manual
SMARTLOGGER
00
Copyright © 2018 Masibus Automation and Instrumentation Pvt Ltd.
(233 – 2273)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HT16U and is the answer not in the manual?

Questions and answers

Summary of Contents for Masibus HT16U

  • Page 1 User Manual HT16U HUMIDITY-TEMPERATURE SMARTLOGGER DOC m94B-OM-101Issue No. Copyright © 2018 Masibus Automation and Instrumentation Pvt Ltd. Customer Support: support@masibus.com Toll Free Number (India Only): 1 – 800 – ADD – CARE (233 – 2273) Operator’s manual Page 1 of 16...
  • Page 2: Table Of Contents

    6.3 Main menu description: 6.4 Quick Log Active Menu Flowchart: 6.5 LCD Messages: (1)Logging START Indication: (2)Logging PAUSE Indication: (3)Logging STOP Indication: (4)USB Connection Indication: (7). HT16u Battery Replacement: CONTACT DETAIL OF SERVICE DEPARTMENT Operator’s manual Page 2 of 16...
  • Page 3: Introduction

    The HT16u Humidity-Temperature Smart Logger is ideal for monitoring humidity and temperature of storage areas, clean rooms and buildings in Pharma and other industries. The HT16u is compact, easy to setup, accurate and most cost effective. HT16u is available in two versions, Temperature only and Temperature with Humidity combined, at the heart of the measurement and logging is the built-in RH &...
  • Page 4: Technical Specifications

    Ref. No: m94B/OM/101 Issue No: 00 (4).TECHNICAL SPECIFICATIONS Input Sensor type Integral Models Parameter HT16u-T HT16u-TRH   Temperature    Humidity Temperature Measurement Measurement Range 0 to 60°C Accuracy ±0.2°C typical, ±0.4°C max <0.03°C /year max Long-term drift...
  • Page 5: Ht16U Mounting

    Ref. No: m94B/OM/101 Issue No: 00 (5). HT16u MOUNTING Operator’s manual Page 5 of 16...
  • Page 6 Ref. No: m94B/OM/101 Issue No: 00 Operator’s manual Page 6 of 16...
  • Page 7: Ht16U Configuration

    Ref. No: m94B/OM/101 Issue No: 00 (6). HT16u Configuration: HT16u Configuration (1)Front (2)SMART-HT menu key Configuration Software 6.1Configuration via front key Panel: Main menu is divided in total 13 categories: (1) Min(Min Value) Mode: (2) MAX(Max Value) Mode: (3) TSPL (Temperature Set Point Low) Mode:...
  • Page 8: Main Menu Flowchart

    Ref. No: m94B/OM/101 Issue No: 00 6.2 Main menu Flowchart: Operator’s manual Page 8 of 16...
  • Page 9: Main Menu Description

    Ref. No: m94B/OM/101 Issue No: 00 6.3 Main menu description: RUN Mode: After powering on the device, unit will display Temperature and Humidity measured by Sensor. Device also shows battery level, alarm indication & Log START/STOP Status. When device stay inactive or user don’t press any key during menu configuration, timeout signal force menu screen to jump into RUN MODE and enter in sleep to save power.
  • Page 10 Ref. No: m94B/OM/101 Issue No: 00 HT16u unit equipped with 2 push button key labeled as Menu key and Up key. UP Key Menu Key (1)MIn Mode: It displays minimum value of measured Temperature and Humidity from last records. (2)MAX Mode: It displays maximum value of measured Temperature and Humidity from last records.
  • Page 11 Ref. No: m94B/OM/101 Issue No: 00 (8)hh.mm.ss (Time) Mode: This mode shows the current hour, minute & second of data-logger. User can set hour, minute & second via SMART-HT configuration software. (9)ltmr(Log-Timer) Mode: This mode shows recording interval of data-logger, user can change record interval via User can only configured lTMR value from below set: menu key.
  • Page 12: Quick Log Active Menu Flowchart

    Ref. No: m94B/OM/101 Issue No: 00 6.4 Quick Log Active Menu Flowchart: This Quick-shortcut menu specially designed to START, STOP & PAUSE device Logging. User can also add time mark for important event indication. Mark event would be written in logger every time mark added.
  • Page 13: Lcd Messages

    Ref. No: m94B/OM/101 Issue No: 00 6.5 LCD Messages: (1)Logging START Indication: Example below represent Logging START indication. As shown in LCD upper bar ‘-‘ above left most digit indicates Logging is Started. When data logging start by key-panel or SMART- HT configuration software unit will punch event log as START in data-report.
  • Page 14: Logging Stop Indication

    Example below represents USB communication indication. When data-logger connected to SMART-HT configuration software via mUSBTTL programming cable following message appear on LCD screen. Ordinary USB data cable not compatible with HT16u. Only use mUSBTTL programming cable provided by MASIBUS. Operator’s manual...
  • Page 15: Ht16U Battery Replacement

    Ref. No: m94B/OM/101 Issue No: 00 (7). HT16u Battery Replacement: Remaining battery life displays on home screen, logger would stop working after battery life ran out. Make sure to check battery status before starting new recording. 1. Lift up mother-board from enclosure by detaching back-case. If necessary, use a small, flat object, such as a flat-tip screw driver or tweezers to lift the mother- board.
  • Page 16: Contact Detail Of Service Department

    Ref. No: m94B/OM/101 Issue No: 00 CONTACT DETAIL OF SERVICE DEPARTMENT Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India +91 79 23287275-79 +91 79 23287281-82 Email: support@masibus.com Web: www.masibus.com Operator’s manual Page 16 of 16...