Gas Forced Heater/ LPG 50KW CT2141
ORIGINAL INSTRUCTIONS
Cannon Tools Limited
Address:20 Station Road, Rowley Regis, West Midlands, B65 0JU.UNITED KINGDOM
SAVE THESE INSTRUCTIONS AND PRECAUTIONS.
READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE.

CIRCUIT DIAGRAM

HEATER SPECIFICATIONS

第 1 页 共 10 页

Advertisement

Table of Contents
loading

Summary of Contents for Nielsen CT2141

  • Page 1: Circuit Diagram

    Gas Forced Heater/ LPG 50KW CT2141 ORIGINAL INSTRUCTIONS Cannon Tools Limited Address:20 Station Road, Rowley Regis, West Midlands, B65 0JU.UNITED KINGDOM SAVE THESE INSTRUCTIONS AND PRECAUTIONS. READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE. CIRCUIT DIAGRAM HEATER SPECIFICATIONS 第 1 页 共 10 页...
  • Page 2: Ec Declaration Of Conformity

    In case of alteration of the machine, not agreed upon by us, this declaration will lose its validity. Product description: Gas Forced Heater/ LPG 50KW Model: CT2141 Applicable EC Directives: EC Low Voltage Directive 2014/35/EU EC Directive of Electromagnetic Compatibility 2014/30/EU...
  • Page 3 ARNINGS YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER. GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONXIDE POISONING, AND/OR ELECTRICAL SHOCK.
  • Page 4: General Instruction

    1. GENERAL INSTRUCTION 1.1. The heaters mentioned in this manual must only be used outdoors or in well ventilated surroundings. 1.2. For every KW it is necessary to have permanent ventilation of 25cm³, equally distributed between the floor and high level, with a minimum outlet of 250cm³.
  • Page 5: Installation

    Figure 1 1.10. Do not use the heater in cellars, basements or in any room below the ground level. 1.11. In case of malfunction, please contact the technical assistance service. 1.12. After use, turn the gas cylinder tap off. 1.13. The gas bottle must always be replaced following safety rules away from any possible source of ignition.
  • Page 6: Switch Off

    Figure.2 b. Push the gas valve button and push repeatedly the piezoelectric lighter until the flame lights up. (Figure. 3-4) Figure.3 Figure.4 c. As the flame lights up, keep the valve button pushed for 10 seconds approx. Should the heater stop when the valve button has been released, wait one minute and repeat the starting operation keeping the valve button pushed for a longer time.
  • Page 7: Maintenance

    5. Lack of proper ventilation air will lead to improper combustion. 6. Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing. FUEL GAS ODOR LP gas and natural gas have manmade odorants added specifically for detection of fuel gas leaks.
  • Page 8 Check that the motor works properly Insufficient gas supply due to Check and use a larger cylinder or ice formation on the cylinder two cylinders connected together. Model identifier(s): CT2141 Indirect heating functionality: [no] Direct heat output: 50(kW) Indirect heat output: N/A (kW)
  • Page 9 Space heating emissions (*) Fuel Select fuel type [gaseous] 118[mg/ kWh ] (GCV) input Item Symbol Value Unit Item Symbol Value Unit Heat output Useful efficiency (NCV) Nominal heat Useful efficiency at nominal η heat output output th,nom Minimum heat Useful efficiency at minimum η...
  • Page 10 (*) NOx = nitrogen oxides The seasonal space heating energy efficiency η Item Symbol Value Unit seasonal space heating Energy efficiency η S,on in active mode Correction factor (F1) Correction factor (F2) Correction factor (F3) Correction factor (F4) Correction factor (F5) Biomass label factor The seasonal space heating η...