Pump Medical BF12150B Instruction Manual

Arm automatic blood pressure monitor

Advertisement

Quick Links

Arm Automatic Blood Pressure Monitor
1. Safety Information ................................................................................................... 2
1.1 Warning .............................................................................................................................. 2 
1.2 Precaution .......................................................................................................................... 2 
2. Product Feature ....................................................................................................... 3
3. Pre Measurement ..................................................................................................... 5
3.1 Battery ................................................................................................................................ 5 
3.2 Power Adapter(Optional) ............................................................................................ 5 
3.3 Setting date and time ........................................................................................................ 6 
4 Take a measurement ................................................................................................. 6
4.1 Important Noted ................................................................................................................ 6 
4.2 Fitting the cuff ................................................................................................................... 7 
4.3 Body posture during measurement .................................................................................. 7 
4.4 Take Measurement ............................................................................................................ 8 
4.5 Data Transmission ............................................................................................................. 9 
4.6 Memory .............................................................................................................................. 9 
5. Error Indication ....................................................................................................... 9
6. Trouble Shooting .................................................................................................... 10
7. Specification ........................................................................................................... 10
8.About Blood Pressure .......................................................................................... 15
8.1 What is Blood Pressure? ................................................................................................. 15 
8.2 What is high blood pressure? ......................................................................................... 15 
8.3 What is morning hypertension (morning surge)? ........................................................ 15 
Reference Standard .................................................................................................... 16
Blood Pressure Measurement Chart ........................................................................ 16
Guarantee Card ......................................................................................................... 17
Instruction Manual
BF1215 (0B)

Table of Contents

1
Rev. A1
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BF12150B and is the answer not in the manual?

Questions and answers

Summary of Contents for Pump Medical BF12150B

  • Page 1: Table Of Contents

    Rev. A1 Arm Automatic Blood Pressure Monitor Instruction Manual BF1215 (0B) Table of Contents 1. Safety Information ....................2   1.1 Warning ..........................2  1.2 Precaution .......................... 2  2. Product Feature ....................... 3   3. Pre Measurement ..................... 5   3.1 Battery ..........................
  • Page 2: Safety Information

    Rev. A1 1. Safety Information 1.1 Warning • Self diagnosis and treatment which use measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. • Those who have arrhythmia, diabetes, blood circulation or apoplexy problem, please use under the physician’s instruction.
  • Page 3: Product Feature

    Rev. A1 • Do not use at extremely high temperature, high humidity, or high altitude. Use only within the required ambient conditions. • Do not place heavy objects on the AC adapter cable, or allow the unit to sit on the cord. •...
  • Page 4 Rev. A1 Cuff Label Fig 2 Note: Symbol for”TYPE BF APPLIED PART” Display Fig 3...
  • Page 5: Pre Measurement

    Rev. A1 3. Pre Measurement 3.1 Battery 3.1.1 Installation and replacement 1) Remove battery cover 2) Load 4 standard AA alkaline battery as indicated in figure below Fig 4 3) Install back the battery cover 4) Replace the battery if low battery icon is displayed •...
  • Page 6: Setting Date And Time

    Rev. A1 • Do not plug in multiple plugs into same power Electric Outlet outlet. • Power adapter specification: Input: AC 100~240 V, • AC adapter 50/60Hz, 400mA; Output: 6.0V 0.5A • Use the manufacturer power adapter only. • Unplug the AC adapter or wires if the device is damaged.
  • Page 7: Fitting The Cuff

    Rev. A1 Rest for 5~10 minutes before taking a reading. Sit in a comfortable, relaxed position. Don't move around or talk while taking the blood pressure. Leave your legs in one position, breath freely and calmly. The blood pressure cuff should fit over about 3/4 of your upper arm. It should easily go around the arm and the Velcro should close tightly.
  • Page 8: Take Measurement

    Rev. A1 Fig 9 4.4 Take Measurement After installing the batteries and wearing the cuff, the unit is ready for measurement: For the most accurate result please relax, do not smoke, take deep breath, speak loudly or move around during the measurement. Turn on the 【ON/OFF】...
  • Page 9: Data Transmission

    Rev. A1 is greater or equal to 90mmHg as abnormal. The display will flash to remind the end user of the blood pressure abnormality. • If the device caused any discomfort during measurement or fail to perform as indicated, turn off the power or discontinue use.
  • Page 10: Trouble Shooting

    Rev. A1 Weak Signal or cuff is too loose Cuff too loose,Confirm the cuff is wrapped up Er 2 correctly(ref 4.2)retake the measurement Calculation error,heavy shock, Remain still, retake the measurement (ref 4.1) Er 3 assembly or hardware error Bad Signal,moving or talking Remain still, retake the measurement (ref 4.1)...
  • Page 11 Rev. A1 power off 4 AA Alkaline battery Power source Battery Life Approx 200 measurements AC Adapter(AC 100~240 V) Protection against electric IP classification IP21 Type BF shock Temperature:+5℃~+40℃; Temperature:-25℃~+70℃; Storage Humidity:≤93% Operating transport Humidity:10%~95% Environment Pressure: 70.0kPa~106.0kPa Environment Pressure:50.0kPa~106.0kPa Altitude: ≤...
  • Page 12 Rev. A1 Guidance and manufacturer’s declaration Guidance and manufacturer’s declaration – electromagnetic emissions The [EQUIPMENT or SYSTEM] is intended for use in the electromagnetic environment specified below. The customer or the user of the [EQUIPMENT or SYSTEM] should assure that it is used in such an environment.
  • Page 13 Rev. A1 (50/60 location in a typical commercial or magnetic hospital environment. field 61000-4-8 Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not LIFE – SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity The [EQUIPMENT or SYSTEM] is intended for use in the electromagnetic environment specified below.
  • Page 14 Rev. A1 Separation distance according to frequency of transmitter Rated maximum output power of 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to2.5 GHz transmitter d = 1.16 d = 1.16 d = 2.33 0.01 0.12 0.12 0.23 0.38...
  • Page 15: 8.About Blood Pressure

    Rev. A1 8.About Blood Pressure 8.1 What is Blood Pressure? Blood pressure (BP) is the pressure exerted by circulating blood upon the walls of blood vessels, and is one of the principal vital signs. Two pressures are measured for a blood pressure reading: •...
  • Page 16: Reference Standard

    Rev. A1 pressure. In fact heart attack, stroke and heart failure have been shown to fall particularly on a Monday amongst all the other days of the week. Organ damage and diabetic complications have also been shown to be linked with morning blood pressure surges just in the same way as small artery disease and multiple celebral infarcts in elder members of society.
  • Page 17: Guarantee Card

    ·This product is medical device, to ensure the accuracy of the product when using it, we would like to continue to provide you with paid services after the guarantee periods. SHENZHEN PUMP MEDICAL SYSTEM CO., LTD. Certificate Product Name: Arm Automatic Blood Pressure Monitor...
  • Page 18 Symbol for“electrical and electronic equipment“ Symbol "AUTHORISED REPRESENTATIVE EUROPEAN COMMUNITY" After-Sale Service Manufacturing Enterprises:Shenzhen Pump Medical System Co., Ltd. ADD: 2/F West, M-7 Sinosteel Building, Maqueling Estate, Hi-Tech Industrial Park, Nanshan District, Shenzhen 518057, China Tel:86-755-26710795/26067119 Fax:86-755-26012025 Service Line:86-4006 755 009 E-mail:service@bpump.com.cn Shanghai International Trading Corp.