MODE
Run
Set Time (Hour) SET TIME
Set Time (Minute) SET TIME
Set On (Hour) ON
Set On (Minute) ON
Set Off (Hour) OFF
Set Off (Minute) OFF
Set Ramp
Set Channel 1
Level
Set Channel 2
Level
Set Channel 1
Minimum Level 005
Set Channel 2
Minimum Level 005
DISPL Y COMMENTS
HH:MM:SS
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
RAMP
MM
CH 1 LEV
100
CH 2 LEV
100
CH 1 MIN
CH 2 MIN
5
Clock display
Use '+' and '-' to
set the time
Use '+' and '-' to
set the time
Use '+' and '-' to
set the on time
Use '+' and '-' to
set the on time
Use '+' and '-' to
set the off time
Use '+' and '-' to
set the off time
Use '+' and '-' to
set the length of
time the dimming
process takes in mins
Use '+' and '-' to set the
on level of Channel 1
as percentage output
Use '+' and '-' to set the
on level of Channel 2
as percentage output
Use '+' and '-' to set the
off level of Channel 1
as percentage output
Use '+' and '-' to set the
off level of Channel 2
as percentage output