Page 3
Instructions for Installation and Use This V ecton unit is supplied with two universal hosetails for connecting the steriliser to the water system. Installation is explained in detail below, but please read the following safety information first. Important Safety Information - Please Read Carefully - Never look directly at an illuminated UV lamp.
Page 4
CONNECTIONTOTHEAQUARIUMWATER SUPPLY Water flow: There is no correct flow direction through the unit. Either port may be used as the inlet or outlet. Connection with flexible hose TheV ecton unit is supplied with two universal hosetails to take ”, ”, 1”and 1 ”...
Page 5
FLOW RATES Do not exceed the maximum flow rates as this will considerably reduce the efficiency of the unit. ecton 120 Nano: For aquariums up to 120 litres/30 imp gal/35 US gal Maximum flow/hr: 360 litres/90 imp gal/105 US gal Always use the largest diameter hose possible, this will ensure that you get the maximum performance from your water pump.
Page 6
If you are carrying out the annual lamp change, use new ‘O’ rings. Firmly hand tighten the compression fittings. Fit a new lamp. Relocate the lampholders and place the unit back into the base. Caution: Ensure that the mains power cable is properly located in the cable slot in the base (see no.