Modular Hi-Rise Series Fan Coils
SECTION II – Product Line Specific Installation
Part 1 – Universal Hi-Rise Units (MUY)
The unique design of the Universal Modular Fan Coil unit
allows for field configuration for each unit. Air discharge,
riser, drain, and outside air knockouts have been strategically
located on each unit. Risers, shown with unit, are for
reference only. All risers are factory fabricated and shipped
loose for field installation.
It is important that you identify all of the unit feature
locations and which knockouts you intend to use before
proceeding with the installation. Also, it must be determined
whether your application requires a Mating Unit (primary/
secondary) and its configuration. Consult your local sales
representative or the factory for further details on primary/
secondary arrangements.
Potential Unit Configurations
Risers: Three Locations–The pre-installed Supply, Return, and
Drain risers (2-pipe or 4-pipe applications) can be oriented on
any of three sides of the unit (see Figure 1).
NOTE: Risers can not be installed on the Return Air side of the
cabinet.
HR
HS
D
MUY
Cabinet
Return Air
R
HR
S
D
R =
Return
HR
D =
Drain
HS
S
=
Supply
D
CR
2- or 4-pipe
CS
Figure 1
Unit orientation is determined based on the location of the
risers in the building. The riser side of the Universal Modular
unit always determines the rear of the unit (see Figure 2).
Return Air: Single Location–The Return Air/Access panel
may then be oriented on the left, right, or front of the unit.
Supply Air: Five Locations (4 sides and top) includes
stitched design for 1/2" duct flanges.
Outside Air: Two Locations–Either side adjacent to the
Return Air opening.
NOTE:
Unit Knockout Locations (Typical)
CR
CS
HS
CR
CS
D
=
Hot Water Return
=
Hot Water Supply
=
Drain
=
Cold Water Return
=
Cold Water Supply
6
Outside Air opening may not be used on a side if risers are
configured on that same side.
SIDE VIEW
Return
Air
Outside Air
Knockout
(2 sides only,
adjacent to
Return Air
opening)
Figure 3A
Side Supply Air
Knockout
(1 per side)
Optional
Electrical
Knockouts
Riser Knockouts
(4 per side,
except on
Return Air side)
Drain Knockout
(1 per side,
except on
Return Air side)
6