INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND HD81.
THIS INFORMATION SUPERSEDES THAT IN THE HD81 INSTALLATION INSTRUCTIONS.
CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Included in this kit:
W010-2362
Assembly, firestop spacer
W175-0001
4" coupler
W175-0013
7" coupler
W175-0310
Connector, reducer 8/10" to 4/7"
W410-0017
5' - 7" flex liner
The HD81 uses 8" and 10" fl exible venting. When installing the GPV for use
with the HD81, the 4"/7" reducer (W175-0310) is required. The reducer must
be properly secured and sealed to the appliance using high temperature
sealant W573-0007 Mill Pac (not supplied)before continuing with vent
installation. The 5' section of stainless steel fl ex liner (supplied) must be
secured and sealed to the corresponding connector using a minimum of 3
screws and high temperature sealant W573-0007 Mill Pac (not supplied). Use
4" and 7" couplers to connect additional vent lengths up to 65 feet.
WARNING: The 5' of stainless steel fl ex liner (supplied) must be installed
directly off the appliance.
TERMINAL INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS
FIRESTOP VENTING INSTALLATION
THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.
DO NOT FILL THE CAVITY BETWEEN THE PIPE AND THE FRAMING WITH ANY TYPE OF MATERIAL.
TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN
This application occurs when venting through an exterior wall. Having
determined the correct height for the air terminal location, cut and
frame a hole in the exterior wall as illustrated to accommodate
the fi restop assembly. Dry fi t the fi restop assembly before
proceeding to ensure the brackets on the rear surface fi t to
the inside surface of the horizontal framing.
The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2" thick but the
vent shield must extend the full depth of the combustible
wall.
A. Apply a bead of caulking (not supplied) around the corner
edge of the inside surface of the fi restop assembly, fi t the fi restop assembly to
the hole and secure using the 4 screws W570-0026 (supplied in your manual
baggie).
B. Once the vent pipe is installed in its fi nal position, apply high temperature
sealant W573-0007 (not supplied) between the pipe and the fi restop.
PVA81 POWER VENT ADAPTOR KIT
INSTALLATION INSTRUCTIONS
WARNING
!
FLANGE OF THE MOUNTING PLATE.
W410-0029
5' - 4" stainless steel flex liner
W500-0420
Plate, electrical box cover
RP8
Restrictor, Kit
W500-0551
Plate, Dilution air
W750-0218
Wire harness, unit
VENT
SHIELD
CAULKING
FIRESTOP
SPACER
14"
7
11
/
"
8
DETERMINE
THE
CORRECT
HEIGHT
FINISHING
MATERIAL
1

Advertisement

loading

Summary of Contents for Napoleon PVA81

  • Page 1 PVA81 POWER VENT ADAPTOR KIT INSTALLATION INSTRUCTIONS INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND HD81. THIS INFORMATION SUPERSEDES THAT IN THE HD81 INSTALLATION INSTRUCTIONS. CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON THE HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AS EVEN AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED.
  • Page 3: Vent Lengths

    VENT LENGTHS It is recommended that the gas power vent be used with a gas appliance that is equipped with Electronic Ignition. When installing the venting, these parameters supersede the Vent Installation Section in the appliance's Installation and Operating Instructions, as well as the following guidelines: Maximum horizontal vent run with no rise is 65 feet total.
  • Page 4: Venturi Adjustment

    VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 5 INSTRUCTIONS D’INSTALLATION DE LA TERMINAISON MÉCANIQUE PVA81 INSTALLATEUR : LAISSEZ CE MANUEL AVEC L’APPAREIL. CES INSTRUCTIONS DOIVENT ÊTRE UTILISÉES CONJOINTEMENT AVEC CELLES DU GPV ET DU HD81. CES INFORMATIONS REMPLACENT LES INSTRUCTIONS D’INSTALLATION DU HD81. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.
  • Page 6 AVERTISSEMENT NE LAISSEZ PAS LA GAINE FLEXIBLE INTÉRIEURE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE INTÉRIEURE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE ÉGAL AVEC LA GAINE FLEXIBLE EXTÉRIEURE. CET ESPACE EST REQUIS POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE.
  • Page 7 LONGUEURS DES CONDUITS D’ÉVACUATION Il est conseillé d’utiliser la terminaison mécanique avec un appareil au gaz muni d’un allumage électronique. Lors de l’installation de l’évacuation, les paramètres suivants remplaceront la section « Installation des évents » dans le manuel d’instructions d’installation et d’opération de l’appareil : La déviation horizontale maximale sans élévation est de 65 pieds en tout.
  • Page 8 RÉGLAGE DU VENTURI L’ouverture du volet d’air a été préréglée en usine selon le tableau ci-dessous : VENTURI Indépendamment de l’orientation du venturi, plus le volet est fermé, plus la flamme est jaune et aura tendance à causer des dépôts de carbone.