Download Print this page

Ikusu SPI-300 Setup Manual

For tpc processors. terrestrial/cable tv

Advertisement

Quick Links

RF IN
RF IN
RF IN
RF IN
+V
+V
+V
AUX
AUX
AUX
IKUSUP
IKUSUP
IKUSUP
IKUSUP
CONTROL
CONTROL
CONTROL
CONTROL
CFP-700
SYNC
STATUS
SYNC
STATUS
SYNC
STATUS
SYNC
POWER
+12V
+12V
+12V
+12V
5A
+24V
+18V
TPC-110
TPC-110
TPC-110
TPC-110
300 mA
(22 KHz)
TV CHANNEL PROCESSOR
TV CHANNEL PROCESSOR
TV CHANNEL PROCESSOR
TV CHANNEL PROCESSOR
+13V
300 mA
(22 KHz)
+18V
300 mA
RF OUT
RF OUT
RF OUT
RF OUT
+13V
300 mA
I
TOT (MAX)
:700 mA
SETUP GUIDE FOR
«TPC» PROCESSORS
USING THE SPI-300 PROGRAMMING UNIT
TERRESTRIAL/CABLE TV
Programming the TPC Processors
1. THE START SCREENS
1.1 - Module Basic Information
As explained in the Basic Handling guide supplied with the SPI-300, when you
connect this to the module, all data for identification, configuration and status of the
module are loaded on the SPI-300. A detection screen appears for a short time, and
next the display shows the Basic Information screen, which identifies the module and
presents its most representative configuration and status data.
The basic information screen for TPC processors is the following:
TPC-010
Inp.Freq.:
Out.Freq. : 231.250
Ch. Width : 8 MHz
These are the meanings of the expressions and data displayed :
- Name of the module.
- "F-.-" : Version of the firmware (the firmware is the software stored in the module
that manages its basic running).
- "Alarm" : Informs about the existence or not of module working failures. Character
"X" warns existence of alarm situation and character "0" means no alarm.
- "Input Frequency" : Is the video carrier of the input channel, in MHz. If the channel
is digital, is the central frequency.
- "Output Frequency" : Is the video carrier of the output channel, in MHz. If the
channel is digital, is the central frequency.
- "Channel Width" : Is the width of the input channel.
The screen closes using the OK command (key
appears (page 8 of the Basic Handling guide).
GB
-30 dB
RF IN
RF IN
RF IN
OUTPUT TEST
OUTPUT
+V
+V
+V
+V
AUX
AUX
AUX
AUX
IKUSUP
IKUSUP
IKUSUP
HPA-120
Ref. 4426
SPI-300
BROADBAND AMPLIFIER
47-862 MHz
CONTROL
CONTROL
CONTROL
CFP-700
GAIN
ON
STATUS
SYNC
STATUS
SYNC
STATUS
SYNC
STATUS
POWER
+12V
+12V
+12V
+12V
+12V
+12V
5A
1
2
3
+24V
AUX INPUT
Gain 5 dB
+18V
TPC-110
TPC-110
TPC-110
300 mA
4
5
6
(22 KHz)
TV CHANNEL PROCESSOR
TV CHANNEL PROCESSOR
TV CHANNEL PROCESSOR
+13V
300 mA
(22 KHz)
+18V
7
8
9
300 mA
INPUT
RF OUT
RF OUT
RF OUT
+13V
300 mA
-20 dB
I
TOT (MAX)
:700 mA
C
0
INPUT TEST
F1.00
Alar:0
471.250
OK
). Then the Main Menu Screen
1. The Start Screens
1.1 - Module Basic Information ...................................................... 3
1.2 - Main Menus .......................................................................... 4
2. The Setting Screens
2.1 - The Input Signal Parameters Screen ............................... 5 / 6
2.2 - The Output Signal Parameters Screen ................................ 7
3. The Information Screens
3.1 - The Alarms Screen ................................................................ 7
3.2 - The Details Screen ................................................................ 8
4. The Divers Screens
4.1 - The Configurations Screen ................................................... 8
1
Programming the TPC Processors
1.2 - Main Menus
As explained in the Basic Handling guide, the General menu is identical for all the
modules and its contents was described on page 8. The Settings and Info menus
include, however, options and information which are peculiar to each type of module.
Those of the TPC processors are the following:
- Settings Menu : Contains all the setting parameters of the connected processor.
They are grouped in two sections :
Input : You must select it to set the parameter values related to the input
section of the module.
Output : You must select it to set the parameter values related to the output
section of the module.
- Info Menu: Allows to get access to detailled information about the functionning of
the module, further on the one provided by the basic information screen (see
previous page). Information is distributed in two screens, each one related to a
menu option:
Alarms : Informs whether the module has some alarm activated and its type.
Details : Identifies the module and displays outstanding data.
3
Index
1  Input
2
Output
ESC
SEL
1  Alarms
2
Details
ESC
SEL
2
4

Advertisement

loading

Summary of Contents for Ikusu SPI-300

  • Page 1 Those of the TPC processors are the following: module are loaded on the SPI-300. A detection screen appears for a short time, and next the display shows the Basic Information screen, which identifies the module and - Settings Menu : Contains all the setting parameters of the connected processor.
  • Page 2 Character "X" warns there is an alarm situation and "0" SPAIN means the status or working are correct: Tel.: +34 943 44 88 00 Fax: +34 943 44 88 19 ALARMS www.ikusi.com Status Hardware: Use the OK command (key ) to close the screen. SPI-300 / TPC -A- (GB)