NOTES
All the data reported in this brochure and the data sheet, like linearity, lifetime, temperature coefficient are
valid for a sensor utilization as a ratiometric device with a max current across the cursor Ic ≤ 0.1 mA.
Do NOT use the linear transducer as variable resistance!
When calibrating the transducer, be careful to set the stroke so that the output does not drop below 1% or
rise above 99% of the voltage level.
MAINTENANCE
The sensors are maintenance free. It is not necessary to lubricate the moving parts.
DECLARATION OF EC-CONFORMITY
WayCon Positionsmesstechnik GmbH
Mehlbeerenstrasse 4
82024 Taufkirchen / Germany
This is to certify that the products
Classification
Linear potentiometer
Series
LZW1
fulfill the current request of the following EC-directives:
EMV-directive
applied harmonized standards:
EN 61000-6-2:2005, EN 61000-6-4:2007, EN 61326-1:2006
The declaration of conformity loses its validity if the product is misused or modified without proper
authorisation.
Taufkirchen, 13.03.2013
2004/108/CE
Andreas Täger
CEO
INSTALLATION GUIDE
Linear Potentiometer Series LZW1
For further information please see the data sheet at www.waycon.biz/products/linear-potentiometers/
FIRST STEPS
WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our
products. This manual will make you familiar with the installation and operation of our linear
potentiometers. Please read this manual carefully before initial operation!
Unpacking and checking:
Carefully lift the device out of the box by grabbing the housing. After unpacking the device, check it for
any visible damage as a result of rough handling during the shipment. Check the delivery for
completeness.
If necessary consult the transportation company, or contact WayCon directly for further assistance.
ELECTRICAL CONNECTION
3 brown (V+)
2 yellow (cursor)
1 blue (V-)
ACCESSORIES
Spare parts
STA074 bracket for LZW1-S
SND001 rod end bearing w ith M4 external
thread, housing side for LZW1-A
SND002 rod end bearing w ith M4 internal
thread, rod side for LZW1-A
Sensor is to be used as voltage divider, using a
maximum cursor current of Ic ≤ 0.1 µA (do NOT use the
sensor as variable resistance!). Please pay attention to
the notes on the last page.
PMX-24 Signal Conditioner
• Converts potentiometer signals into analog output
signals: 4...20 mA, 0...10 V, 0...5 V, ±10 V, ±5 V
• Input: potentiometer 1...20 kΩ
• Configurable output
• DIN-rail-mounting with face-side connector
• For further information please
check the PMX-24 data sheet,
or contact WayCon

Advertisement

loading

Summary of Contents for Waycon LZW1 Series

  • Page 1 All the data reported in this brochure and the data sheet, like linearity, lifetime, temperature coefficient are WayCon Positionsmesstechnik GmbH would like to thank you for the trust you have placed in us and our valid for a sensor utilization as a ratiometric device with a max current across the cursor Ic ≤ 0.1 mA.
  • Page 2 INSTALLATION GUIDE Linear potentiometer Series LZW1 For further information please see the data sheet at www.waycon.biz/products/linear-potentiometers/ TECHNICAL DRAWING TECHNICAL DATA LZW1-S: installation with brackets Useful electrical stroke B: corresponds to the sensors measurement range Theoretical electrical stroke C: actual length of the conductive path, that has to be longer than B, in order bracket STA074 (2 pieces to get a valid electrical signal at the start and end point of the measurement range.

This manual is also suitable for:

Lzw1-aLzw1-s