Cogent Systems 1. Power On Mobile Verifier (MV3) Press power button to power on the device. Power Button Login page will show up once the device is powered on. Enter user name and password (Test Demo: Username‐Cogent, Password‐3259600), click Login to go into the Front Page (Fig. 1) Fig. 1 ...
Cogent Systems 2. Manual Check Click Manual Check in Front Page, MobileID II Test page will show up. MobileID II Test page is the main page of Manual Check. 2.1. Memory Click Memory, Memory Check dialogue will pop up. Click Start, it will calculate the memory disk automatically. After finishing memory calculation, click Quit (Fig. 2.1). Fig.2.1 4 ...
Cogent Systems 2.2. Display Click Display and get into it. Click Color, the screen will turn to red, blue, white and black automatically. After that it will go back to Display page. Adjust backlight by using BackLight Adjust Bar. Click OK to return to MobileID II Test page if there is no error. ...
Cogent Systems 2.4. Key Click Key, Key Check dialogue will pop up. Power button (cancel button) is the right top key and OK button is the left top key. The interface will show the corresponding action when press cancel button and OK button. Press OK button, Left top key down will pop up, loosen it, Left top key up will pop up. Then use the same method to check cancel button. Click OK if it pass the test, click Fault if it is failed. ...
Cogent Systems Fig.2.5 2.5.1. Swipe Card Install the swipe card reader on the back of device. Click Swipe Card and go to the test page. Swipe the magcard on the swipe card module, there should be three rows of information of the card showing in the blank box (Fig.2.5.1). Three rows of card’s information will be shown here ...
Cogent Systems Writing area Numeric area Fig.2.5.2 2.5.3. ICCARD Insert IC card into the IC card reader, click ICCARD, test procedure is the same as contactless card. 2.6. Voice Click Voice and get into it. Adjust voice by adjusting the voice bar. 8 ...
Cogent Systems 2.7. VibratMotor Click VibratMotor and get into it. Press Start, the device will be vibrated, press Stop, it will stop to vibrate. 2.8. Finger Adjust Click FingerAdjust and get into Camera Adjust page. Clean the fingerprint sensor, then click start to adjust the camera. Click OK on the pop up dialogue after adjusting carema. ...
Cogent Systems 2.10. Facial Camera Click FacialCamera to get into Facial Check page. Click Capture to capture the image, click Save to save the image. Connect the device to PC to check the image. 2.11. Power Click Power to get into Power Check page. Select wireless you wish to open. To open wireless, you can also go into Wireless page in Front page. ...
Cogent Systems 2.12. WIFI Go into Power Check page or Wireless page to power on the Wifi module. Make sure other wireless modules are power off. Then Click WIFI in Manual Check and get into Wifi Check page. Change the server ...
Cogent Systems Will show date here if GPRS connect successfully 2.14. Bluetooth Go into Power Check page or Wireless page to power on the Bluetooth module. Make sure other wireless modules are power off. Click Bluetooth in Manual Check and get into it. Click Scan Device. It will scan devices automatically. Click Quit back to Manual Check. ...
Cogent Systems 2.15. Barcode Click Barcode in Manual Check and get into it. Barcode camera light (red) will turn on while scanning barcode. The distance between barcode tester and MV3 should be in 8‐16cm. 13 ...
Page 14
Cogent Systems 8‐16cm After the beep, MV3 finish scanning the barcode. Now the barcode data is showed on the barcode page. Please notice the scanned barcode under should be same as the number on barcode tester. ...
Cogent Systems barcode tester is in 8‐16cm (can be adjusted according the scan situation). 3. Photo Click Photo in Front page. Click Capture to capture the image. Click Photo List, it will show all photos you captured. Click Exit back to Front page. 4. Settings Click Settings in Front page. 15 ...
Cogent Systems 4.1. Volume Click Volume and get into it. Adjust the volume by adjusting volume bar. 4.2. Date Click Date, adjust the date by clicking ‘- ‘ or ‘+’. Click Save to save your change. ...
Cogent Systems 4.3. Screen Calibration Click Screen Calibration and get into it. Click the central of the cross until it finished the calibration. 4.4. Fingerprint Calibration Click Fingerprint Calibration and get into it. Clean the fingerprint sensor, click Start. It will calibrate the sensor automatically. After calibrating, it will return to the Settings page automatically. 17 ...
Cogent Systems 4.5. LCD Click LCD and get into it. Adjust the LCD brightness by clicking ‘‐‘ or ‘+’ , click Save to save change. 5.
Page 19
Cogent Systems The next step is fingerprints captured. Enter ten fingerprints as instructed, it will capture fingerprints automatically. After capturing ten fingerprints, click Save to save the data then click OK, it will go into next step. 19 ...
Cogent Systems The next step is face image captured. 5 face image need to be captured: Face_0, Face_L45, Face_R45, Face_L90, Face_R90. Click Capture to capture the face image, click Save to save the data, click OK to return back to main page. 5.2. Search Click Search, a dialogue will pop up. Select ByFinger. Press finger on the fingerprint sensor. If the fingerprint get the hit, it will show on the top, and ...
Page 21
Cogent Systems Select ByFacial. Capturing face Captured face image image Detected face image FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 21 ...
Page 22
Cogent Systems NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. 22 ...
Need help?
Do you have a question about the Mobile Verifier 3 and is the answer not in the manual?
Questions and answers