Typing in a '3' will display the current Pan Joystick Speed Factor
THE CURRENT PAN JOYSTICK SPEED FACTOR = 0.50
ENTER PAN JOYSTICK SPEED FACTOR (0.05 to 1.00) FOLLOWED BY <CR>(OR 'Q' TO QUIT):
Changing this parameter will change the Pan joystick's sensitivity.
Enter the Pan Joystick Speed Factor with up to two decimal places.
Note: Input values outside the limit range are rejected (with 'ENTRY EXCEEDS LIMITS - TRY AGAIN'
message) and the unit returns to the previous message.
Typing in a '4' will display the current Pan Axis Stability Factor
THE CURRENT PAN AXIS STABILITY FACTOR = 0.50
ENTER PAN AXIS STABILITY FACTOR (0.05 to 1.00) FOLLOWED BY <CR>(OR 'Q' TO QUIT):
Changing this parameter will change the Pan Axis Stability or responsiveness. Please contact
Factory before changing this as it could make the Servo System unstable
Enter the Pan Joystick Speed Factor with up to two decimal places.
Note: Input values outside the limit range are rejected (with 'ENTRY EXCEEDS LIMITS - TRY AGAIN'
message) and the unit returns to the previous message.

Set New Home Position

Typing in '&' will bring up the following menu.
TYPE IN THE NUMBER OF YOUR SELECTION (OR 'Q' TO QUIT):
1 = ADJUST TIME CONSTANT
2 = SET JOYSTICK/AXIS PARAMETERS
3 = SET OUTPUT CHANNELS
4 = LIST CURRENT OUTPUT CHANNEL SELECTION
5 = SET NEW BAUD RATE
To update the Home Position, typing in '2' will bring up the following menu.
TYPE IN THE NUMBER OF YOUR SELECTION (OR 'Q' TO QUIT):
1 = ADJUST TILT AXIS PARAMETERS
2 = ADJUST PAN AXIS PARAMETERS
3 = SET NEW HOME POSITION
Typing in a '3' will update the Home position to current Servo System Orientation.