Feig Electronic ID RW02.ABC-A:
ID RW02.ABC-B Installation Instructions Manual
Feig Electronic ID RW02.ABC-A:
ID RW02.ABC-B Installation Instructions Manual

Feig Electronic ID RW02.ABC-A: ID RW02.ABC-B Installation Instructions Manual

Rs232/rs485 interface

Advertisement

Quick Links

®
OBID
ID RW02.ABC-A
ID RW02.ABC-B
FEIG ELECTRONIC GmbH
Installation
(RS232 Interface)
(RS485 Interface)
(english)
ID RW02.ABC
Page 1 of 18

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID RW02.ABC-A: ID RW02.ABC-B

  • Page 1 ® OBID Installation ID RW02.ABC ID RW02.ABC-A (RS232 Interface) ID RW02.ABC-B (RS485 Interface) (english) FEIG ELECTRONIC GmbH Page 1 of 18...
  • Page 2 GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
  • Page 3: Table Of Contents

    Address setting (Bus mode with RS485 interface)..........13 (F) Technical data Approval ........................15 USA (FCC)........................15 Dimensions for concealed installation ..............16 Dimensions for surface installation with ID APR-A ..........17 System delivery contents: Optional Accessories ....................18 FEIG ELECTRONIC GmbH Page 3 of 18...
  • Page 4: Safety Instructions

    • Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. • When working on devices the valid safety regulations must be observed. Page 4 of 18 FEIG ELECTRONIC GmbH...
  • Page 5: Installation

    Before any installation the intended position of the Reader should be tested for its suit- ability. • The opening (A) in the casing (see Fig 1) has to be installed downwards! Fig 1: mounting direction (A) downwards FEIG ELECTRONIC GmbH Page 5 of 18...
  • Page 6: Installation On Flush-Mounting Box

    • Screw top of casing to bottom part by using thread cutting screw 3,2 x 25 mm. • Attach adhesive label to clean and non-greasy casing. Fig 2: Rear view with snapped-in connection board (1) Page 6 of 18 FEIG ELECTRONIC GmbH...
  • Page 7: Installation With Surface Frame Id Apr-A

    Attach label to clean and non-greasy casing +/~ -/~ R COM NO GND R/A T/B CLK DAT IN1 IN2 Fig 3: Surface installation (LED top left) Open surface casing with snapped-in connection board (1) FEIG ELECTRONIC GmbH Page 7 of 18...
  • Page 8: Reader-Connection

    GND RS232 - RxD RS485 - A RS232 - TxD RS485 - B data-/clock interface – clock data-/clock interface – data digital input 1 (IN1) digital input 2 (IN1) Table 1: connection plan Page 8 of 18 FEIG ELECTRONIC GmbH...
  • Page 9: F) Jumper And Switches

    Terminal for sticking up the connection board. X2 / X3 / X4: Jumper for termination resistors of the RS485 interface (only ID RW02.ABC-B). Interface for firmware update. J1 / J2: Jumper for firmware update. FEIG ELECTRONIC GmbH Page 9 of 18...
  • Page 10: Power Supply

    Fig 6: connection of the digital inputs 3.5 RS232 Interface (ID RW02.ABC-A) Readers with RS232 interface have to be connected to the host according to Fig 7. Host ID RW02 Fig 7: connection of the RS232-interface Page 10 of 18 FEIG ELECTRONIC GmbH...
  • Page 11: F) Rs485 Interface (Id Rw02.Abc-B)

    (default) resistor termination resistor Fig 9: Jumper positions of the RS485 interface 1 kΩ T / B 100Ω R / A 1 kΩ Fig 10: intern construction of the RS485 interface FEIG ELECTRONIC GmbH Page 11 of 18...
  • Page 12: F) Data-/Clock Interface

    The connection of the data-/clock interface is executed according to Fig 11. If no CLS signal is required on host, this connection can be abandon. Host CLOCK DATA ID RW02 Fig 11: connection of the data-/clock interface Page 12 of 18 FEIG ELECTRONIC GmbH...
  • Page 13: Operation

    Bus mode with 16 - 32 Readers: The setting of addresses is executed by the host-PC (host). NOTE: Due to the default value 0 of each Reader, they have to be connected and configu- rated one after another. FEIG ELECTRONIC GmbH Page 13 of 18...
  • Page 14: F) Technical Data

    DIP-switch 8-channel EEPROM 10.000 writing cycles Default values (factory alined): asynchronous interface: 9600 Baud, 8 data- 1 stopbit, even parity activates LED red and relay aktivates LED green and buzzer LED-operation control orange Page 14 of 18 FEIG ELECTRONIC GmbH...
  • Page 15: Approval

    If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used: This device contains transmitter module FCC ID PJMRW02 FEIG ELECTRONIC GmbH Page 15 of 18...
  • Page 16: Dimensions For Concealed Installation

    ® OBID Installation ID RW02.ABC 5.3 Dimensions for concealed installation Fig 12: Dimensions of concealed casing (A) = below Page 16 of 18 FEIG ELECTRONIC GmbH...
  • Page 17: Dimensions For Surface Installation With Id Apr-A

    ® OBID Installation ID RW02.ABC 5.4 Dimensions for surface installation with ID APR-A Fig 13: Dimensions for installation with surface frame ID APR-A (A) = below FEIG ELECTRONIC GmbH Page 17 of 18...
  • Page 18: System Delivery Contents

    2 x thread cutting screws 3,2 x 15 mm (for wall installation) 1 x Installation instructions 6.1 Optional Accessories bottom part of casing for surface installation ID APR-A Order-No.: 1144.001.00 adhesive front label ID AKL.02 Order-No.: 1424.000.00 Page 18 of 18 FEIG ELECTRONIC GmbH...

Table of Contents