Current consumption @ 230 Vac: 15 mA with short input and relays energized. Max. power consumption: at 250 Vac supply voltage, short circuit input and relays energized, 2.0 W for 2 channels D1130D, 1.9 W for 1 channel D1130S. Isolation (Test Voltage): I.S. In/Out 2.5 KV; I.S. In/Supply 2.5 KV; Out/Supply 2.5 KV; Out/Out 2.5 KV.
Ordering information Model: D1130 1 channel 2 channels Front Panel and Features • Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. • Universal AC supply voltage (85 to 250 Vac, 48 to 400 Hz). •...
Output Ch 2 Common Output Ch 2 Relay Normally Opened (NO) Output Ch 2 Relay Normally Closed (NC) Output Ch 1 Relay Normally Closed (NC) D1130S HAZARDOUS AREA SAFE AREA + Input Ch 1 for Proximity or Output Ch 1-A Common...
Page 5
Parameters Table In the system safety analysis, always check the Hazardous Area/Hazardous Locations devices to conform with the related system documentation, if the device is Intrinsically Safe check its suitability for the Hazardous Area/Hazardous Locations and gas group encountered and that its maximum allowable voltage, current, power (Ui/Vmax, Ii/Imax, Pi/Pi) are not exceeded by the safety parameters (Uo/Voc, Io/Isc, Po/Po) of the D1130 series Associated Apparatus connected to it.
Out 1 1 COM voltage free Proximity Contact 7 NC 6 NO In 2 Out 2 5 COM MODEL D1130S 4 N Supply 115-230 Vac voltage free Proximity Contact 8 NC 2 NO In 1 Out 1-A 1 COM 7 NC...
ON the fault LED) or be disabled (in case of fault the corresponding output channel relay repeats the input line open or close status as configured). D1130S (single channel type) has one input channel and two output relays; the unit has two DIP switch configurable operating modes: A) Input channel actuates in parallel output relays SPDT contacts (providing a DPDT type of output).
On the section “Function Diagram” and enclosure side a block diagram identifies all connections and configuration DIP switches. Identify the number of channels of the specific card (e.g. D1130S is a single channel model and D1130D is a dual channel model), the function and location of each connection terminal using the wiring diagram on the corresponding section, as an example: Connect AC power supply (85 to 250 Vac, 48 to 400 Hz) at terminal “3”...
Page 9
Configuration A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. Line fault Disabled Setting detection (contact / proximity sensor) Enabled (proximity sensor or contact with terminating line resistor) Input Output...
Page 10
NO-NE or NC-ND (contact/proximity sensor) Enabled (proximity sensor or contact with terminating line resistor, NO-ND or NC-NE detects field open circuit and short circuit de-energizing output) D1130S Configuration Summary Table IN/OUT Operation Line fault detection B Output Operation Mode Direct...
Need help?
Do you have a question about the D1130S and is the answer not in the manual?
Questions and answers