    IMediaChassis Series Advantech B+B SmartWorx - Americas 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 Fax (815) 433-5105 Advantech B+B SmartWorx - European Headquarters Westlink Commercial Park Oranmore, Co. Galway, Ireland Phone +353 91-792444 Fax +353 91-792445 www.advantech-bb.com...
  • Page 3: Table Of Contents

    IMediaChassis Series CONTENTS B+B SMARTWORX TECHNICAL SUPPORT…………………………… i List of Figures………………………………………………………………. iv FCC RADIO FREQUENCY INTERFERENCE STATEMENT…………. v Class A ...................... vi Class B ...................... vi WARRANTY………………………………………………………………. viii ABOUT THE IMEDIACHASSIS/20……………………………………….. 1 HARDWARE FEATURES…………………………………………………. 1 Alarm Reset, Last Gasp and Temperature Gauge ......1 Alarm Reset Button .................
  • Page 4 IMediaChassis Series Temperature Gauge ..............12 SNMP Write Lock ................13 Installing the iMediaChassis/6 .............. 13 DC Power Wiring, Replacing Power Supply Modules and Fans ..15 DC Power Supply Wiring Instructions ..........15 User-Replaceable Power Supply Modules ........15 Fans ....................
  • Page 5: List Of Figures

    IMediaChassis Series LIST OF FIGURES Figure 1: iMediaChassis/20, all models ............2 Figure 2: SNMP Write Lock Switch ............... 3 Figure 3: DC Wiring Scheme ................. 5 Figure 4: 850-10960-2AC PS ................. 7 Figure 5: 850-10960-2DC PS ................8 Figure 6: 605-10144-2AC PS ................. 9 Figure 7: 605-10144-2DC PS ................
  • Page 6: Fcc Radio Frequency Interference Statement

    IMediaChassis Series FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class x computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,...
  • Page 7: Class A

    IMediaChassis Series Class A This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 8 IMediaChassis Series Product Version Description Class A Class B  Dual AC iMediaChassis/20  Dual DC  iMediaChassis/6  Dual AC   Dual DC  iMediaChassis/3     ACDC...
  • Page 9: Warranty

    B+B SmartWorx’ products. THE REPAIR OR REPLACEMENT OF THE DEFECTIVE ITEMS IN ACCORDANCE WITH THE EXPRESS WARRANTY SET FORTH ABOVE IS B+B SMARTWORX’...
  • Page 10: About The Imediachassis/20

    The iMediaChassis series is a modular chassis platform designed for use with B&B Electronics’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/20 is a 3U high, rack mountable chassis that features 20 slots for installing application series modules plus an additional slot for installing an SNMP Management Module.
  • Page 11: Alarm Reset Button

    IMediaChassis Series User-Replaceable Power Supply Modules Figure 1: iMediaChassis/20, all models ALARM RESET BUTTON When one power supply module malfunctions, an audible alarm sounds indicating the loss of the power module. The alarm can be silenced by pressing the Alarm Reset Button, located next to the power connector on the power supply module.
  • Page 12: Temperature Gauge

    IMediaChassis Series TEMPERATURE GAUGE The iMediaChassis/20 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent sends a trap (configured in iView²) to the administrator.
  • Page 13: Snmp Management Module Leds

    Glows yellow when one module malfunctions. Glows yellow when a fan malfunctions. FAN A / FAN B Installing the iMediaChassis/20 Install the chassis first before installing any modules into an iMediaChassis. When installing the chassis, be sure to observe the following precautions to prevent electrical or mechanical damage: 1.
  • Page 14: Dc Power Supply Module Wiring Instructions

    Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the B+B SmartWorx. 5. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
  • Page 15: Installing Snmp Management And Application (Imcv-) Modules

    Discharge Precautions section. In order to manage an iMediaChassis series, the SNMP Management Module needs to be installed in the appropriate slot of the chassis. Install the iMediaChassis/20 SNMP Management Module into the first slot of the chassis. NOTE This slot is ONLY for the Management Module; do not install Application Modules...
  • Page 16: Replacing Power Supply Modules

    IMediaChassis Series REPLACING POW ER SUPPLY MODULES USER REPLACEABLE POW ER SUPPLIES The iMediaChassis power supply modules are redundant *, failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss. To replace a power supply module: 1.
  • Page 17: Dual Dc, Part Number 850-10960-2Dc

    IMediaChassis Series DUAL DC, PART NUMBER 850-10960-2DC Figure 5: 850-10960-2DC PS Both the 850-10960-2AC and 850-10960-2DC were put on End-of-Life “EOL” in June 2015; support is still available for existing chassis deployed. Power supplies are limited to a six year warranty.
  • Page 18: Dual Ac, Part Number 605-10144-2Ac

    IMediaChassis Series DUAL AC, PART NUMBER 605-10144-2AC Figure 6: 605-10144-2AC PS DUAL DC, PART NUMBER 605-10145-2DC Figure 7: 605-10144-2DC PS...
  • Page 19: Imediachassis/20 Specifications

    IMediaChassis Series iMediaChassis/20 Specifications Input Specifications Dual AC 100 to 240V AC, 50/60Hz, 3.5/1.5A Dual DC -48V DC, 5A ACDC 100 to 240V AC, 50/60HZ, 2A -48V DC, 4.4A Operating Temperature 0° C to 50° C (32° F to 122° F) Storage Temperature Dual AC &...
  • Page 20: About The Imediachassis/6

    ABOUT THE IMEDIACHASSIS/6 The iMediaChassis series is a modular chassis platform designed for use with B+B SmartWorx Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/6 is 1U high, can be installed on a rack mount shelf, and supports optional redundant power supply modules, as well as an SNMP Management Module.
  • Page 21: Hardware Features

    IMediaChassis Series HARDWARE FEATURES ALARM RESET, LAST GASP, AND TEMPERATURE GAUGE The iMediaChassis series supports modular power supply modules, so that worn parts can be replaced without having to send an entire unit in for repair. Keeping fans functional ensures that the modules will operate within their temperature specifications.
  • Page 22: Snmp Write Lock

    IMediaChassis Series SNMP W RITE LOCK There is an SNMP Write Lock switch located above the SNMP module slot on the front of the iMediaChassis/6. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings (e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SNMP on any previous Management Modules.
  • Page 23 (Tma) specified by the B+B SmartWorx. 5. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
  • Page 24: Dc Power Wiring, Replacing Power Supply Modules And Fans

    Figure 9: DC Wiring Scheme for iMediaChassis/6 USER-REPLACEABLE POW ER SUPPLY MODULES The iMediaChassis/6 ships from B+B SmartWorx with one or two power supply modules installed depending on the model. Chassis ordered with one power supply come with a filler tray installed in the second slot.
  • Page 25: Fans

    To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. B+B SmartWorx recommends installing blank brackets in unused module slots. 2. Slide the module into the chassis using the card guides.
  • Page 26: Imediachassis/6 Specifications

    IMediaChassis Series IMEDIACHASSIS/6 SPECIFICATIONS Input Specifications 100 to 240V AC, 50/60Hz, 1A -48V DC, 2A Operating Temperature: -25° C to 50° C (-130° F - 122° F) -40° C to 100° C (-40° F - 212° F) Storage Temperature: -40° C to 85° C (-40° F - 185° F) -55°...
  • Page 27: About The Imediachassis/3

    ABOUT THE IMEDIACHASSIS/3 The iMediaChassis series is a modular chassis platform designed for use with B+B SmartWorx’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/3 is a 1U high, can be mounted on a rack shelf, capable of offering redundant power supply modules, and supports an SNMP Management Module.
  • Page 28: Last Gasp Alarm

    IMediaChassis Series LAST GASP ALARM The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis Down”, which sends a Trap when the following occurs: • Both power supply modules malfunction • Both power supply modules are powered down • When the AC line fails TEMPERATURE GAUGE The iMediaChassis/3 includes a temperature monitoring gauge with a heat sensor on the SNMP Management Module.
  • Page 29: Dc Power Wiring, Replacing Power Supply Modules And Fans

    IMediaChassis Series The Rackmount shelf is sold separately. To purchase the Rackmount shelf, (part number #895-39949, visit the B+B SmartWorx’ Product Accessories page. 4. Attach the cables between the chassis and the device that will be interconnected, and then plug the unit into a reliable, filtered power source.
  • Page 30: Power Supply Modules

    IMediaChassis Series DC Power Supply Negative ground system configuration (default position) Figure 11: DC Wiring Scheme iMediaChassis/3 NOTE Incorrect wiring will result in chassis malfunction. The iMediaChassis/3 is compliant with Isolated Grounding Plane practices. The POSITIVE and NEGATIVE terminals are isolated from chassis ground and must have a ground reference at the power-sourcing equipment.
  • Page 31: Installing Applications Modules

    To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. B+B SmartWorx recommends installing blank brackets in unused module slots. 2. Slide the module into the chassis using the card guides.
  • Page 32: Imediachassis/3 Specifications

    IMediaChassis Series NOTE Leave this switch in the NORMAL position during day-to-day operation; the LOCKED position should only be used when changing the SNMP management board. The SNMP Management Module can be removed and replaced as necessary. Refer to the SNMP Management Module manual for complete instructions about how to configure and operate.
  • Page 33: Hardware Feature Matrix

    IMediaChassis Series Humidity: 5 to 95% (non-condensing); 0 to 10,000 ft. altitude Shipping Weight: 5 lbs (2.3 kg) Dimensions: 4.4 x 19.0 x 22.0 cm (1.73H 7.50W 8.74D inches) Hardware Feature Matrix Power Supply iMediaChassis/3 Versions AC, 2AC, DC, 2DC*, ACDC Type Fixed End user replaceable...
  • Page 34: Electrostatic Discharge Precautions

    IMediaChassis Series ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand-alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products: Do not remove unit from its protective packaging until ready to install. Wear an ESD wrist grounding strap before handling any module or component.
  • Page 35: Certifications

    © 2017 B+B SmartWorx. All rights reserved. The information in this document is subject to change without notice. B+B SmartWorx assumes no responsibility for any errors that may appear in this document. iMediaChassis is a trademark of B+B SmartWorx.