  • Page 1 Roger Access Control System RWH-1 v1.x RACS AIR Wireless Hub Operating Manual Firmware version: 1.0 Document version: Rev. B...
  • Page 2: Design And Application

    RWH-1 Operating manual.doc 2018-11-30 Design and application RWH-1 is a wireless hub dedicated to RACS 5 AIR system. The hub enables connection of wireless devices to RS485 bus and their control by MC16 access controller or other device which controls the bus (e.g. bus expander).
  • Page 3: Radio Channels

    The low level configuration of RWH-1 hub and other wireless devices of RACS 5 AIR system is done with RogerVDM software and RUD-1 communication interface.
  • Page 4: Configuration Parameters

    · When RUD-1 is inserted into computer USB port, short RST pins and orange LED SYSTEM indicator on the hub shall pulsate frequently. · Start RogerVDM software. · Select type of device (RWH-1), RS232 communication channel and serial port with connected RUD-1 interface. · Select required settings.
  • Page 5: Wireless Network Configuration

    PAN IDs must be additionally specified. The furthest lock should be located in maximal distance of 10 meters from RWH-1 hub. It is also recommended to avoid any obstacles, particularly metal ones in the straight line from hub to lock. The network creation with RogerVDM is described below.
  • Page 6: Led Indicators

    If it’s necessary to remove the device from the RACS AIR network then select the lock and press Remove device button. Note: The command removes the device from the RWH-1 configuration. To complete the process, you must delete the wireless network configuration or perform a factory reset of the wireless device in accordance with its instruction manual.
  • Page 7 Connection cable should be led through the hole in the base and connected to the screw terminals at hub front panel. Connection diagram with access controller is shown in fig. 4. Fig. 3. RWH-1 base Page7 of 11...
  • Page 8 RWH-1 Operating manual.doc 2018-11-30 Fig. 4. Connection between hub and controller Page8 of 11...
  • Page 9 RWH-1 Operating manual.doc 2018-11-30 Fig. 5. Enclosure opening hole RWH-1 screw terminals Terminal Description Power supply Ground RS485 communication bus; line A RS485 communication bus; line B Use/installation guidelines · All electric cables must be connected to devices with disconnected power supply.
  • Page 10: Specification

    RWH-1 Operating manual.doc 2018-11-30 Damages resulting from improper maintenance and use are excluded from manufacturer warranty. Specification Parameter Value Supply voltage Nominal 12VDC, min./max. range 10-15VDC Current consumption 40mA Communication interface with RS485; maximal cable length: 1200m controller Communication interface with IEEE 802.15.4/ 2.4GHz wireless communication;...
  • Page 11 Weight of the equipment is specified in the document. Contact: Roger sp. z o.o. sp.k. 82-400 Sztum Gościszewo 59 Tel.: +48 55 272 0132 Fax: +48 55 272 0133 Tech.