INSTALLATION AND USER MANUAL
200TDHW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMBI 200TDHW and is the answer not in the manual?

Questions and answers

Summary of Contents for Stafor COMBI 200TDHW

  • Page 1 INSTALLATION AND USER MANUAL 200TDHW...
  • Page 2: General Indications

    INSTALLATION AND USER MANUAL 200TDHW 1. INTRODUCTION This product, has been manufactured according to the European Quality Standards, incorporates prime grade materials and its correct working has been tested before it leaves our facilities. Through this Installation and User Manual, you will be guide towards the correct and safety installation of the product. It is necessary to carefully read this manual before make any handling to avoid problems arising from the misuse of the product. The company reserves the right to modify the information included in this document at any time without prior notice. 2. GENERAL INDICATIONS 2.1. Safety notes The incorrect or inappropriate use of this product could lead to hazardous situations, causing damage or injuries to the user, third parties or even to the product itself or material goods. The installer has the responsibility to install the minimum safety devices (hydraulic and electrical) set out in this Manual. In case of failure, the lack of any device may cause burns or other injuries. The installer has the responsibility to inform the user about the function and placement of the safety devices installed into the device and the installation. The water outlet temperature could reach 62 degrees.Do not touch the pipes while the system is working to avoid any risk of burns. 2.2. Installer’s qualification Since the installation of the 200TDHW involves handling coolant as well as carry out welding work, it is needed the technical staff have the official certification that accredits them as authorized to handle coolants. The installer must explain the user the application of the product and the use and management of the unit, and he should provide the user all the documentation supplied with the equipment. 2.3. Package contents The 200TDHW system comprises the following components: Thermodynamic panel Anchoring elements 200TDHW V0REV1EN0218...
  • Page 3: Technical Information

    INSTALLATION AND USER MANUAL 200TDHW Silent-Blocks User Manual 2.4. Indications about transport and unpacking the unit The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport. The material used to the packing are recyclables, so dispose it in an appropriate container. Use a forklift or hand pallet truck to transport the unit to the installation site, always introducing the forks into the bottom of the pallet being careful not to damage the unit. In case you identify any damage at the time of the reception of the unit, it is mandatory to register it in the reception note of the transport company, and then, submit the complaint. For this reason it is recommended to make a thorough visual inspection of the goods before signing the reception note. 3. TECHNICAL INFORMATION 3.1. Operating Principle Figure 1: Operating principle 3.2. Dimension drawings It is possible to remove the side and front casing access easily to any part of the system. V0REV1EN0218...
  • Page 4 INSTALLATION AND USER MANUAL 200TDHW Figure 2: Exploded view V0REV1EN0218...
  • Page 5 INSTALLATION AND USER MANUAL 200TDHW Figure 3: Dimensions, mm A: 585 B: 633 C: 1620 D:1102 E: 161 F: 250 Figure 4. Front connections Figure 5. Back connections F: Refrigerant inlet G: Refrigerant outlet H: Power supply, 230V/1PH/50 HZ I: Condensate drain J: Hot water outlet, ¾’’ K: Cold water inlet, ¾’’ L: Recirculation connection, ¾’’ M: Electronic anode N: Temperature probe O: Electrical heater P: Anode display V0REV1EN0218...
  • Page 6: Installation Steps

    INSTALLATION AND USER MANUAL 200TDHW 3.1. Technical data Cylinder 200DHW Capacity, L 200 Maximum operating pressure, bar Heat pump data Energy Efficiency Class Load profile Heating capacity range *, W 1430-2560 Input power range *, W 450-540 Maximum temp. HP, ºC Maximum temp. electric element, ºC Coolant R134A Electric data Power supply, V/ph/Hz 230/1/50 Electric element power, W 1500 Maximum current, A 10,1 Maximum power absorbed, W 2100 Thermodynamic panel Number of panels Dimensions, mm 1700x800 Maximum operating pressure, bar Refrigerant inlet/ outlet, inch 3/8 - 3/8 4. INSTALLATION STEPS Before starting the installation, check the availability of all the necessary components and tools: High and low pressure manometers Vacuum pump Scales Nitrogen bottle...
  • Page 7: Hydraulic Installation

    INSTALLATION AND USER MANUAL 200TDHW Pipe expander Welder Copper Rods (40% Silver) Insulating hose Drill Screwdriver Hydraulic installation components Electric installation components Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps: 1. Placing and anchoring panels 2. Joining and welding the refrigerant pipes 3. Placing the 200TDHW 4. Joining and welding liquid and suction line between 200TDHW and panel 5. Nitrogen pressure test (maximum10 bar) 6. Vacuum 7. Filling refrigerant installation 8. Hydraulic installation 9. Electric installation 10. Commissioning 11. Adjustment of refrigerant load 5. THERMODYNAMIC SOLAR PANEL INSTALLATION 5.1. Site selection The choice of the installation site of the thermodynamic panel is a key factor in the final performance of the unit. For this reason, we recommend to follow the indications in order to achieve the best performance: South orientation is indeed the best to take the maximum advantage of solar radiation.
  • Page 8 INSTALLATION AND USER MANUAL 200TDHW 1700 1700 When the panel is installed in If the panel is installed at vertical position, always the inlet horizontal position, refrigerant and outlet connection has been inlet pipe should be connected at the bottom. (It is not allow to into the bottom connection. install the reverse) Distances to 200TDHW: The maximum allowed distance from the panel to the 200TDHW is 12 meters. In the picture below is shown the dimensions of the panel: 1700 5.2. Anchoring panel Beside the panel, it is supplied a bag with anchoring elements that contains the following pieces: 6 x Aluminium support (L shape) 6 x Screws M5 12 x Nuts M5 18 x Washer 5 18 x Sheet Metal Screws 18 x Blocks M6 Anchor the panels using the lateral and front holes to the suitable surface. V0REV1EN0218...
  • Page 9 INSTALLATION AND USER MANUAL 200TDHW 6. PLACING 200TDHW The place where the system will be installed should allow an easy access in order to make maintenance work or inspection. Beside these factors, it is important to take into account the following indications regards the installation site: The system has been designed and manufactured for it indoors utilization. In case the system has to be placed outdoors, it must be protected against the adverse weather conditions (direct solar radiation, rain, snow…) Try to place 200TDHW as near as possible of the panels’ installation, and also near to the buffer tank. Installer must install the supplied Silent blocks to avoid the transmission of vibration. 7. CONNECTION BETWEEN 200TDHW AND PANEL 7.1. Join refrigerant pipes Panels are supplied with two nuts for the inlet and outlet connection. The inlet to each panel is 1/4 inch diameter. The installer has to insert the nut into the copper pipe, flare the pipe and then use the nut to fit it. Repeat the procedure with the outlet connection using 3/ 8 inch copper pipe. Then, join the suction line that comes from the panel to the coolant inlet of 200TDHW, and the liquid line to the coolant outlet. The connections are threaded, if welding is needed, weld by oxyacetylene welding. IMPORTANT (Only when welding is needed): It is recommended to weld pipelines by oxyacetylene welding. Welding is a critical step in the installation and to do it well ensures that the system will run properly along its useful life. Only expert staff should make this step by using proper tools and high quality materials. 7.2. Nitrogen test and cleaning procedure In order to check the tightness, introduce nitrogen by using the pressure gauge already installed into load ports. V0REV1EN0218...
  • Page 10 INSTALLATION AND USER MANUAL 200TDHW CAUTION: Never exceed a nitrogen load greater than 10 bars. Use leaking detector fluid at every welding and even in panel’s connections to verify the absence of leaks. 7.3. Vacuum Connect the vacuum pipe to the pressure gauge to carry out a vacuum of the whole installation. 7.4. Coolant filling Open the load ports to fill the circuit with the refrigerant loaded into the system. 8. HIDRAULIC CONNECTION The hydraulic connections are shown in the following scheme: The installer must install the following components of the hydraulic circuit: Ball valves (1) V0REV1EN0218...
  • Page 11: Electrical Connection

    INSTALLATION AND USER MANUAL 200TDHW Lined Filter Strainer (Y Type) (3) Pressure reducing valve (5) Expansion vessel (2) Safety valve (6) Once the hydraulic connections are made, vent the circuit to avoid the air inside the installation. 9. ELECTRICAL CONNECTION The power supply of the system is 230/1/50 Hz. NTC1: In tank water temperature I1-I2: To inverter C2-C1: Off-peak signal D: Display connection P: Pressostat R: Electrical element K: Compressor 10. CURRENT IMPRESSED ANODE The system incorporates as standard an impressed current anode that automatically protect the tank against the corrosion. The electronic device is installed inside the ECOHEAT, together with the controller and has a LED indicator in the bottom. CAUTION: To check the proper functioning of the anode, the tank should be plenty of water. The user should check regularly the state of the anode through the LED indicator: LED is highlighted in green: Correct operation of the anode LED off: Check the power supply. If it is correct, contact with the installer for an inspection. Once the hydraulic connections are made, vent the circuit to avoid the air inside the installation. V0REV1EN0218...
  • Page 12 INSTALLATION AND USER MANUAL 200TDHW iFH 200 foreground instruction book P. 3 Z.I. Les levées, 38470 VINAY, FRANCE , 11. COMISSIONING. CONTROLLER. Tel. +33 4 76 36 82 97, Fax +33 4 76 64 05 43 11.1. User interface description INTRODUCTION: iFH Foreground is the generic term to designate the display module that enable a end-user to control a water heater equipped with iQuaFlex®...
  • Page 13: Installation

    INSTALLATION AND USER MANUAL 200TDHW 11.2. Installation After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON. All segments of the LCD display are set ON for few seconds. At first initial power ON, the product goes, by default, in Eco mode with blinking horizontal segment. Blinking segment indicates a first installation or a power shut down exceeding 24h. By pressing any key, default set temperature will be display. At first installation or after a long power cut-off it is recommended to setup the time clock. (Select with Mode button, “TIME” mode to initialize the time) 11.3. Mode selection The 200TDHW unit has 7 modes : To move from one mode to another, press shortly b utton. Few seconds after your last selection, the default value associated to your mode will be display. V0REV1EN0218...
  • Page 14 INSTALLATION AND USER MANUAL 200TDHW Symbols Mode selection key Mode Description Vacation mode indication Eco Water heating is performed using the Heat pump only Increase and navigation key Program mode indication Automatically switch between heat pump and heating Decrease and navigation key Time setting Auto element based on the input air temperature and inner Validation key Information performances of the heat pump. Eco mode indication Heat pump in operation Out of Home Anti frost. A number of day can be indicated Auto mode indication...
  • Page 15 INSTALLATION AND USER MANUAL 200TDHW A solid temperature indication shows the current in-tank temperature. A blinking temperature indication with an arrow shows the requested temperature value. 11.5. Time setting This setting is mandatory before using program mode Select the clock mode to set hours, minutes and days. In time setting mode, the display indicates, alternatively, the current day and time setting. Pressing on key, enable to modify the setting of the displayed value. Values can be modified by using o r k eys accordingly, and validated by pressing Validation by After hours setting , minutes update is proposed, following the same approach. V0REV1EN0218...
  • Page 16 INSTALLATION AND USER MANUAL 200TDHW 11.6. Boost Boost is a single shot function that enables to heat the entire volume of 200TDHW to the requested set temperature, in the shortest time. Both source of heating energy (heat pump and heating element) will be use simultaneously. At any time, during boost process, the set temperature can be adjusted. Boost process can be cancelled, by the selection of a new operating mode. After Boost mode, the water heather will automatically go back to the operating mode selected before Boost. 11.7. Out of home Out of Home mode may be set for long absence period limiting energy consumption during this period. In Out of Home mode, 200TDHW will keep the water at a minimum of 4°C preventing any risk of water freezing. By default, the number of vacation days is undefined indicating an unlimited period of time. If no period is specified then the 200TDHW will stay in Out of home mode until you change the mode manually. You can select the number of days by pressing or b uttons. After the specified period, the water heather will automatically go back to the operating mode selected before vacation. Example: 3 days out of home setting V0REV1EN0218...
  • Page 17 INSTALLATION AND USER MANUAL 200TDHW 11.8. Program In Program mode, 200TDHW operates according to preset heating periods. A program can be defined for an entire week, on a day per day basis. CAUTIOUS : Program mode is only available after correct time setting (Cf. Time Setting) and Off-peak mode disabled. Program mode is selected while the symbol appears at the top of the display. In Program mode, 200TDHW will switching automatically between heat pump and heating element based on the input air temperature and inner performances of the heat pump. To access the programming function, press the OK key while you are in program mode. Limitation: The cumulated programmed heating period per day must represent a minimum cumulative period of 8 hours which are necessary for a minimum performance of the heat pump. If time has not been set previously to programming: Invitation for time setting V0REV1EN0218...
  • Page 18: Anti Short Cycle

    INSTALLATION AND USER MANUAL 200TDHW USER M 11.9. O FF - P E A K ECOHEAT TD CONT This mode is only available when the 200TDHW has been correctly installed and connected in Off- peak (or Night tariff) configuration. In this configuration Program mode is not applicable and it is 9. O F F - P E A K 9. O F F - P E A K automatically disabled. This mode is only available when the ECOHEAT has been correctly installed and connected This mode is only av The off-peak detection can be activated/ deactivated by a long press on “OK” buttons or by set “I3”...
  • Page 19: Child Lock

    INSTALLATION AND USER MANUAL 200TDHW 11.12. Antillegionella The anti-legionnella feature reduces the risk of development of bacteria in the tank. When the water heater is installed and in operation a process will permanently monitor the water temperature. The process is applicable in all modes. Whenever risk conditions are detected that might cause the development of bacteria, 200TDHW background will automatically perform a full water heat cycle above 60°C. Anti-legionella can be disable or enable in the installer menu. iFH 200 foreground instruction book 11.13. Child-lock Z.I. Les levées, 38470 VINAY, FRANCE , Tel. +33 4 76 36 82 97, Fax +33 4 76 64 05 43 CHILD LOCK A long press simultaneously on and...
  • Page 20 INSTALLATION AND USER MANUAL 200TDHW The usage of the heat pump in % during last 30 days The usage of the heating element in % during last 30 days Ex : the following screens shows 38 Kwh for past 30 days . The Heat pump was used 78% of heating time compare to 22% for the heating element. 11.15. Black light The LCD display is backlight offering a high visibility comfort in dark condition. LCD backlight will be activated each time the product is turn ON or on any key press. Backlight will automatically turn off after a time out of 10s without user interaction. 11.16. Photovoltaic option 200TDHW enable the interface with a photovoltaic energy manager or inverter. With this option , when energy is available from th e photovoltaic panels, the water heater is forced to heat the water in order to store the free energy. Heating on photovoltaic (so-called “PV”) can be activated by the energy manager or the photovoltaic inverter when 200TDHW is in Eco Mode/ Auto mode or program mode. The water is going to heat up to the maximum heating capacity of the heat pump (62°C maximum). In this configuration, heating element is not operational and PV characters are displayed. V0REV1EN0218...
  • Page 21 INSTALLATION AND USER MANUAL 200TDHW 11.17. Installer menu Installer menu is accessible by a simultaneous pressing of and keys This menu enables to perform testing for maintenance purposes and to change mandatory setting due to installation configuration. Setting parameters are identified by an “I” + figure while test functions are identified by “T” + figure V0REV1EN0218...
  • Page 22 INSTALLATION AND USER MANUAL 200TDHW Setting Values Information 1 or 2 1 = Indoor setting. Heat pump air source is from local room. 2 = outdoor setting. Heat Pump air source is from outdoor 1 = Off-peak installation. Water heater is installed in Off-peak configuration. Off-peak wiring signal is connected and (Default) operational or 1 0 = Off-peak disable. Off Off = PV function Off (Default) (default) Value from 1 to 20 = Minimum Sun exposure duration before to 20 PV ON in Minute. 0 or 1 1= Anti-legionella ON / 0 = Anti-legionella OFF t’1 2 digits NTC1 temperature value t’2 2 digits NTC2 temperature value t’3 2 digits NTC3 temperature value t’4 2 digits NTC4 temperature value Setting Values Informations 0 or 1 1= 30s of compressor test 0 or 1 1 = 30s of Heating element test 0 or 1 1 = 30s of fan speed 1 test...
  • Page 23 iFH 200 fore Tel. +33 4 76 36 82 97, Fax +33 4 76 64 05 43 Z.I. Les levées, 38470 VINAY, FRANCE , Z.I. Les levées, 38470 VINAY, FRANCE , Tel. +33 4 76 36 82 97, Fax +33 4 76 64 05 43 iFH 200 foreg Tel.
  • Page 24 INSTALLATION AND USER MANUAL 200TDHW STAFOR, 53a Kuldigas str., Riga, Latvia, LV1046, www.stafor.lv info@stafor.lv This company reserves the right to modify the information contained herein without prior notice. V0REV1EN0218...

Table of Contents