Operating instructions: SWK-2000/40/WSA filter mobile

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWK-2000/40/WSA and is the answer not in the manual?

Questions and answers

Summary of Contents for Separ Filter SWK-2000/40/WSA

  • Page 1: Operating Manual

    Operating manual SWK-2000/40/WSA filter mobile These operating instructions are valid for: SWK-2000/40/WSA filter mobile HW Version 0.9 and 1.0 SW Version 19.0 Article No.: 06 2386 Doc. No.: D10053.EN Rev.: 14 Page 1 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 2: Table Of Contents

    Selection of the automatic pump disconnection and the dry-running monitoring..... 23 10.5 Water sensor ..........................25 Notes on use ......................26 11.1 Maintenance ..........................26 11.1.1 Water drain ..........................26 11.1.2 Filter change ..........................26 Doc. No.: D10053.EN Rev.: 14 Page 2 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 3 W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen 11.1.3 Sensor technology........................26 11.2 Filter bowl cleaning ........................27 11.3 Water sensor cleaning ......................... 27 Declaration of conformity ..................28 Index ........................29 Doc. No.: D10053.EN Rev.: 14 Page 3 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 4: References

    Willibrord Lösing Filterproduktion GmbH W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen References [R1] Type: Installation instructions Title: Installation instruction SEPAR english.pdf Doc. No.: D10053.EN Rev.: 14 Page 4 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 5: General

    (steel), the plastic parts (polyamides) and the seals (NBR) is not planned, and can lead to damage to the filter mobile or to dangerous operating states. All work on the SWK-2000/40/WSA filter mobile must be implemented in voltage-free status. Doc. No.: D10053.EN Rev.: 14...
  • Page 6: Scope Of Delivery

    W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Scope of delivery • SWK-2000/40/WSA filter mobile • 12 V supply line with crocodile clips, plug connector, fuse holder and fuse protection (50 A). Doc. No.: D10053.EN Rev.: 14 Page 6 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 7 W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen • 230 V supply line with plug incorporating grounding contact and PowerCon plug connector • Operating manual Doc. No.: D10053.EN Rev.: 14 Page 7 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 8: Technical Data

    -40°C to 80°C Mechanical data IP Protection Type: IP41 Maximum supply capacity of the pumps: approx. 40 l/min Maximum net positive suction head: approx. 2 m Doc. No.: D10053.EN Rev.: 14 Page 8 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 9: Weight And Dimensions

    W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Weight and dimensions Dead weight (without fuel): 65 kg The dimensions (tolerances < 5 mm) can be taken from the following drawing. Doc. No.: D10053.EN Rev.: 14 Page 9 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 10: Transport Grip

    Pivot the transport grip up until the knurled screws can be turned into one of the upper two bores. Tighten both knurled screws clockwise hand-tight for the fixing of the transport grip. Opened-out transport grip Knurled screws (one per side) Doc. No.: D10053.EN Rev.: 14 Page 10 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 11: Electrical Connections

    Further design implementations on request. Mechanical connections The SWK-2000/40/WSA filter mobile is provided with two fuel lines. The fuel suction pipe is equipped filter-sided with a shut-off valve and at its end with a check valve, and the output line is...
  • Page 12: Connection

    Willibrord Lösing Filterproduktion GmbH W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Connection The SWK-2000/40/WSA filter mobile is connected with a suitable voltage supply.  Mains connection via delivered power cable (115 V AC; 230 V AC): ...
  • Page 13: Network Or Battery Connection Cable Dismantling

    After that, the plug connector can be pulled simply from the socket. Interlocking Doc. No.: D10053.EN Rev.: 14 Page 13 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 14: Indications And Operating Elements

    W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Indications and operating elements For the operation of the SWK-2000/40/WSA filter mobile two buttons, an emergency switch, two indication LED's, one display, one pressure indication and a shut-off valve are available.
  • Page 15: Function

    W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen The SWK-2000/40/WSA filter mobile is equipped with a pressure indication. A dirt accumulation of the filter element can be identified in good time using this instrument by the pressure decrease in the filter system.
  • Page 16: Fuel Filling Nozzle

    As soon as the fuel filling nozzle dips into the fuel during pump operation, the interlocking is released and the fuel filling nozzle closed. Push tapping lever of the gun Engage interlocking lever. Fuel filling nozzle is now open. Doc. No.: D10053.EN Rev.: 14 Page 16 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 17: Pump And Filter Operation

    Before beginning the pump and filter operation, the shut-off valve and the fuel filling nozzle are to be opened. The filter mobile is now ready for operation. Doc. No.: D10053.EN Rev.: 14 Page 17 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 18 An actuation of the emergency switch (press down forcefully in the direction of front panel) ends all pumping procedures and the electrics and electronics disconnect from the supply voltage. Doc. No.: D10053.EN Rev.: 14 Page 18 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 19: Timer Function

    The simultaneous actuation of the keys ”+; faster” and ”-; slower” or the actuation of the Emergency Off switch interrupt the timer operation and end the pumping procedure. The filter mobile returns to the basic status. Doc. No.: D10053.EN Rev.: 14 Page 19 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 20: Fault Reports

    A T T E N T I O N Failure: < 10 V! The fault report is deleted by connection of the correct operating voltage. Doc. No.: D10053.EN Rev.: 14 Page 20 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 21 An excessive amount heat with the pump or electronics can have various reasons; amongst those are too high ambient temperature and a too high viscosity of the pumped and filtered media. Doc. No.: D10053.EN Rev.: 14 Page 21 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 22: Selection Of The Display-Language

    The language selected in each case is stored and retained for the following operation, also when the filter mobile is switched off and on again. After the language selection, the filter mobile changes into standard operation, as described in the previous sections. Doc. No.: D10053.EN Rev.: 14 Page 22 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 23: Automatic Pump Disconnection And Dry-Running Monitoring

    The timer keys “+” and “-” can now be released. With the keys “+” and “-” (in this case the two right- hand keys), the operating mode can be selected. Doc. No.: D10053.EN Rev.: 14 Page 23 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 24 The key “-” selects the manual operating mode, with which the pump motor must be switched off manually in case of dry running. In the display the signal appears: Dry-running monitor manually Doc. No.: D10053.EN Rev.: 14 Page 24 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 25: Water Sensor

    The red LED changes into flashing mode. In the display the signal ”Too much water” appears in the same rhythm. After removal of the fault, red LED and the display again indicate the result of the measurement. Doc. No.: D10053.EN Rev.: 14 Page 25 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 26: Notes On Use

    W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Notes on use The SWK-2000/40/WSA filter mobile may not be employed in case of damage to the filter casing, the supply lines and the electrical cables. In this case, repair is necessary with the manufacturer.
  • Page 27: Filter Bowl Cleaning

    Chapter 11.1.3.1. The employment of sharp cleaning tools or sharp and peaked objects can lead to damage to the sensor surfaces and therefore must be avoided. Doc. No.: D10053.EN Rev.: 14 Page 27 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 28: Declaration Of Conformity

    Willibrord Lösing Filterproduktion GmbH W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen Declaration of conformity Doc. No.: D10053.EN Rev.: 14 Page 28 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...
  • Page 29: Index

    Bolt-securing agent Motor temperature Cleaning agent Notes on use Display Operating voltage Dry running monitoring Sensor surface Emergency switch Shut-off valve Hardware version Software version Language selection Doc. No.: D10053.EN Rev.: 14 Page 29 of 29 Operating instructions: SWK-2000/40/WSA filter mobile...