Fitting Instructions
CONTOUR P12 Shower Waste Pump
TYPICAL ELECTRIC SHOWER INSTALLATION
•
1
•
3
TYPICAL MIXER SHOWER INSTALLATION
•
1
•
2
•
3
'
Manufactured
from parts that
are 100% recyclable
1. Flowswitch within the cold water supply
•
2. Electric shower
2
3. Gully
4. 22mm fl exible pipework to pump inlet
5. 22mm fl exible pipework to outlet
6. Contour P12 pump & housing
7. To mains supply 230V
8. Control box
•
7
•
6
•
•
4
5
1. 2 Flowswitches fi tted in the water supply,
one in the cold & one in the hot supply.
2. Mixer shower
3. Waste
4. 22mm fl exible pipework to pump inlet
5. 22mm fl exible pipework to outlet
6. Contour P12 pump & housing
7. To mains supply 230V
8. Control box
•
•
7
•
6
•
•
4
5
PLEASE NOTE:
An additional fl ow switch is required
for mixer shower installations.
INSTALLATION GUIDELINES
READ BEFORE BEGINNING YOUR
INSTALLATION TO ENSURE YOU
MAINTAIN P12 AT PEAK PERFORMANCE.
ANY VARIATION WILL IMPEDE THE PUMP'S
PERFORMANCE.
•
!
8
If you are installing an electric shower & single flowswitch, see
sections A, B & D
If you are installing a mixer shower & two flowswitches, see
sections A, B, C & D
If you are installing an electric shower with a direct link which
does not require a flowswitch, see sections A, B & D.
The 22mm flexible pipework supplied must be used from
the gully to the pump's inlet.
The maximum length between the waste and the
pump should be no more than 2 metres.
For optimum performance of 12 litres per minute we
recommend the pump be installed no higher than 350mm
from the top of the shower waste outlet to the underside of the
wall plate. The pump can be installed upto a maximum height
of 500mm to the underside of the wall plate, but this will
reduce the pump's overall performance.
See Note 3a, overleaf, for Gannet shower tray
installations.
8
A SUITABLE MEANS OF ISOLATION MUST BE PROVIDED.
THE SUPPLY TERMINALS CAN BE ISOLATED BY ALL-POLE
DISCONNECTION. A QUALIFIED ELECTRICIAN MUST
MAKE THE MAINS ELECTRICAL CONNECTION.
THE PUMP MUST NOT BE FITTED IN THE
SHOWERING AREA.
Technical Helpline: 0845 402 9924
READ
ME!
ENSURE
YOU USE THE
22mm Flexible
Pipe supplied.
Issue 3 - JAN 2017