Contour P12 Fitting Instructions Manual

Contour P12 Fitting Instructions Manual

Shower waste pump

Advertisement

Fitting Instructions
CONTOUR P12 Shower Waste Pump
TYPICAL ELECTRIC SHOWER INSTALLATION
1
3
TYPICAL MIXER SHOWER INSTALLATION
1
2
3
'
Manufactured
from parts that
are 100% recyclable
1. Flowswitch within the cold water supply
2. Electric shower
2
3. Gully
4. 22mm fl exible pipework to pump inlet
5. 22mm fl exible pipework to outlet
6. Contour P12 pump & housing
7. To mains supply 230V
8. Control box
7
6
4
5
1. 2 Flowswitches fi tted in the water supply,
one in the cold & one in the hot supply.
2. Mixer shower
3. Waste
4. 22mm fl exible pipework to pump inlet
5. 22mm fl exible pipework to outlet
6. Contour P12 pump & housing
7. To mains supply 230V
8. Control box
7
6
4
5
PLEASE NOTE:
An additional fl ow switch is required
for mixer shower installations.
INSTALLATION GUIDELINES
READ BEFORE BEGINNING YOUR
INSTALLATION TO ENSURE YOU
MAINTAIN P12 AT PEAK PERFORMANCE.
ANY VARIATION WILL IMPEDE THE PUMP'S
PERFORMANCE.
!
8
If you are installing an electric shower & single flowswitch, see
sections A, B & D
If you are installing a mixer shower & two flowswitches, see
sections A, B, C & D
If you are installing an electric shower with a direct link which
does not require a flowswitch, see sections A, B & D.
The 22mm flexible pipework supplied must be used from
the gully to the pump's inlet.
The maximum length between the waste and the
pump should be no more than 2 metres.
For optimum performance of 12 litres per minute we
recommend the pump be installed no higher than 350mm
from the top of the shower waste outlet to the underside of the
wall plate. The pump can be installed upto a maximum height
of 500mm to the underside of the wall plate, but this will
reduce the pump's overall performance.
See Note 3a, overleaf, for Gannet shower tray
installations.
8
A SUITABLE MEANS OF ISOLATION MUST BE PROVIDED.
THE SUPPLY TERMINALS CAN BE ISOLATED BY ALL-POLE
DISCONNECTION. A QUALIFIED ELECTRICIAN MUST
MAKE THE MAINS ELECTRICAL CONNECTION.
THE PUMP MUST NOT BE FITTED IN THE
SHOWERING AREA.
Technical Helpline: 0845 402 9924
READ
ME!
ENSURE
YOU USE THE
22mm Flexible
Pipe supplied.
Issue 3 - JAN 2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Contour P12

  • Page 1 MAINTAIN P12 AT PEAK PERFORMANCE. 4. 22mm fl exible pipework to pump inlet ANY VARIATION WILL IMPEDE THE PUMP’S 5. 22mm fl exible pipework to outlet 6. Contour P12 pump & housing PERFORMANCE. 7. To mains supply 230V 8. Control box •...
  • Page 2 Optional Control Box Ref: 05PP16 STANDARD KIT REF: 05PP01A Ref: 05PP11 Optional Flow Switch cover Ref: 05PP17 LINK PUMP ONLY: 05PP01A-L GETTING TO KNOW YOUR CONTOUR P12 PUMP • EARTH TERMINAL • PUMP TERMINALS By swapping the wires around the pump will change direction.
  • Page 3 SECTION A Installing the pump Shower tray waste Floor former waste USE THE WASTE / GULLY SUPPLIED. USE THE COLLAR PROVIDED TO PROTECT THE FLEXIBLE CAN BE RETRO FITTED TO OTHER PIPE WHEN DETAILING THE FLOOR COVERING. MANUFACTURERS COMPATIBLE WASTES. The 22mm flexible pipe supplied must be used from the 22mm outlet gully or waste to the pumps inlet.
  • Page 4 NEVER INSTALL THE CONTROL BOX IN THE DIRECT P12 PUMP CAN BE LINKED DIRECTLY WITH A MIRA SHOWER AREA. REMOVE & DISPOSE OF ANY ADVANCE ATL FLEX EXTRA OR REDRING SELECTRONIC CARDBOARD / FOAM TRANSPORT PACKAGING.
  • Page 5 P12 pump has 3 LED indicators. P12 pump has 10 variable speed settings. Using this dial P12 can be adjusted to match the Turn the finger control clockwise to increase the INPUT = Flowswitch is connected and water is flowing.
  • Page 6 For Gannet top access shower trays the pump should be fitted no higher than 350mm from the tray outlet to the underside of the P12 wall plate. Ideally, the run-off from the pump should fall gradually to the outlet. However, the P12 Pump is capable of providing a head of water in excess of 3.5 metres with •...
  • Page 7 CONTOUR P12 Shower Waste Pump CONTOUR P12 Shower Waste Pump It is IMPORTANT you read the P12 instructions supplied before the P12 instructions supplied before beginning your installation to ensure you beginning your installation to ensure you maintain the pump at it’s peak performance.