Sierra Monitor Corporation PSE530 Series Operation Manual

Pressure sensor

Advertisement

Quick Links

Pressure Sensor
Operation Manual
PSE530 Series
Thank you for purchasing the SMC PSE530 Series Pressure
Sensor.
Please read this manual carefully before operating pressure
sensor and understand pressure sensor, its capabilities and
limitations. Please keep this manual handy for future reference.
URL http://www.smcworld.com

SAFETY

The Pressure Sensor and this manual contain essential
information for the protection of users and others from possible
injury and property damage and to ensure correct handling.
Please check that you fully understand the definition of the
following messages (signs) before going on to read the text,
and always follow the instructions.
IMPORTANT MESSAGES
Read this manual and follow its instructions. Signal words
such as WARNING and NOTE will be followed by important
safety information that must be carefully reviewed.
Indicates a potentially hazardous situation
which could result in death or serious
injury if you do not follow instructions.
WARNING
Do not disassemble, remodel ( including change of
printed circuit board ) or repair.
An injury or failure can result.
Do not operate beyond specification range.
Fire, malfunction or sensor damage can result.
Do not operate in a combustible gas or explosive
gas atmosphere.
Fire or an explosion can result.
This pressure sensor is not an explosion proof type.
Installation
(addendum information)

Attaching the connector to the lead wire

Sensor wire is stripped as shown in
Connector
the right figure.
cover
20mm or more
The Insulation of the corresponding
color shown in the following table is
put into the pin of the number stamped
on the connector for sensor connection to the bottom.
Pin No.
Color of Insulation
1
Brown (DC (+) )
2
N.C.
3
Blue (DC (-) )
4
Black (IN:1 to 5VDC)
It checks that the above-mentioned preparation
work has been performed correctly, and A part
shown in right figure is pushed by hand and makes
temporary connection.
A part center is straightly pushed in by tools, such as pliers.
Re-use cannot be performed once it connects the connector for
sensor connection completely.
A sensor connector cannot be taken apart for
reuse once it is crimped.If the wire arrangement
is incorrect or if the wire insertion fails,
use a new sensor connector.
When connecting the connector to
PSE200/PSE300 series, please use
the connector for Sensor Lead Wire(ZS-28-C) or
Maker
Model No.
(c)Sumitomo 3M
37104-3101-000FL
Tyco Electronics AMP
3-1473562-4
OMRON
XN2A-1430
Please contact with each connector maker about

OPERATOR

●This operation manual has been written for those who have
knowledge of machinery and apparatus that use pneumatic
equipment and have full knowledge of assembly, operation
and maintenance of such equipment.
●Please read this operation manual carefully and understand it
before assembling, operating or providing maintenance
service to the pressure sensor.
NOTE
Follow the instructions given below when handling your
pressure sensor. Otherwise, the sensor may be damaged
or may fail, thereby resulting in malfunction.
・Do not drop it, bring it into collision with other objects or apply
excessive shock ( 980m/s
2
or more).
・Do not pull the lead wire with force nor lift the main unit by
holding the lead wire. ( Pulling strength less than 23N)
・Do not insert wire nor other article into the pressure port.
・Perform wiring and cable correctly.
・Do not perform wire or cable while power is on.
・Do not wire with the same circuit of power line or high-voltage
line.
・Connect Terminal FG to the ground when using a switching
regulator obtained on the commercial market.
・Keeping from water and dust, set an air tube to the safety
area.
Connector
Connector Connecting / Disconnecting
When connecting the connector, insert it straight onto the pin
holding the lever and connector body between fingers and lock
the connector by pushing the lever claw into the square groove
in the housing until connector clicks.
Insulation
When disconnecting the connector, push down the lever by
thumb to disengage the lever claw from the square groove.
Then pull the connector straight out.
PSE200 Series
A
Lever
Connector for Sensor
Lead Wire

Example of Internal Circuit and Wiring

Output Specification

Voltage output :
as below.
1 to 5V
1k Ω
Output impedance :
Approx. 1k Ω
catalogue.
How to connect the cable for sensor.(Optional)
Pick with fingers the hemale connector of cable for sensor.
Insert it paying attention of connector direction.
Male connector
Female connector
Cable for sensor have connector cover in order to prevent fall of
female connector. Paying attention for connector cover direction,
install on the sensor, rotate clockwise, and lock it.
To remove cable for sensor, rotate the connector cover anti-
clockwise, relese lock, and remove connector cover.
After removing connector cover, pick with female connector with
fingers and pull out.
Lock
Connector cover
Unlock

Outline with Dimensions

PSE53 -M5
3.4
PSE300 Series
PSE53 - R06
R07
3.4
Lever
Model No.
PSE53 -R06
PSE53 -R07
When connect cable for sensor
)
+
Brown DC (
Black OUT
(Analog output)
+
12 to 24V
-
DC
)
-
Blue DC (

Specification

PSE530- ※
Model No.
Rated pressure range
0 to 101MPa
Withstand pressure
1.5MPa
Fluid
Power supply
12 to 24VDC, ripple(p-p)10% or less (Protection against inverse connection)
Current consumption
Sensor
Voltage: 1 to 5V±2%F.S. or less (Rated pressure range)
Analog
Voltage
output
output
Linearity : ±1%F.S. or less Output impedance : Approx.1kΩ
Repeatability
Effect form power supply
±1%F.S. or less with standard of analog output at 18V in the range of 12 to 24VDC
Temperature Characteristic
Enclosure
Ambiebt temperature
Operation : 0 to 50℃,Storage :-10 to 70℃ (No condensation, No freezing)
1000VAC, 50/60Hz, 1minute (Between lead block and case)
Withstand voltage
Insulation resistance
10 to 500Hz smaller one 1.5mm or 98m/s
Vibration proof
Impact proof
980m/s
Standard
Cable
Halogen free heavy insulation cable, φ2.7, 0.15mm

Piping Specification

Sensor
Model No.
Port size
Material
With cable(3m)
Weight
Excluding cable
in mm
(
)
M5
0.8
29.4
Pressure port
27.2
3
12
4
5 5.5
45.5
Pressure port
43.3
Applicable port size(D)
6mm
1/4inch
9.8
PSE531- ※
PSE532- ※
PSE533- ※
0 to -101kPa
0 to 101kPa
-101 to 101kPa
500kPa
Air, Non-corrosive gases, Incombustible gases
15mA or less
±1%F.S. or less
±2%F.S. or less (25℃ reference)
IP40
5MΩ or more 500VDC (Between lead block and case)
2
double amplitude, 2 hours each in direction
of X, Y and Z
2
3times each in directions of X ,Y and Z respectively
CE MARKING
2
, 3wire, 3m
M5
R06
R07
M5×0.8
φ6 Reducer
1/4inch Reducer
Sensor pressure sensing part : Silicon O-ring : NBR
Body : SUS303
Body : PBT
41g
38g
7g
3.8g