Protective Vents
Specifications
PolyVent
Part Description
M12x1
PMF100318 PMF100391
Part Number
PMF100319
Through Hole (Bulkhead Mounting) Installation
Through Hole (Bulkhead Mounting) Installation
Through Hole
(± 0.2 mm)
NA
Counter Nut
Part Number
NA
Chamfer Specifications for O-Ring Seal
Chamfer Specifications for O-Ring Seal
Angle
OD for Wall
Thickness > 3 mm
OD for Wall
Thickness < 3 mm
Torque
Specification
0.6 – 0.8 Nm (0.44 – 0.59 lbf-ft)
Other Useful Information
Other Useful Information
Thread Angle
Major OD
* Note: If using the Metal Vent PMF100444 at temperatures below –20°C, mechanical protection for
the vent is recommended (e.g. protective ring). Additional installation and handling instructions are
available upon request.
Storage Recommendations
Store in the original packaging in a clean and dry environment.
Contact Us
For additional assistance, please contact a Gore representative.
international contacts
Argentina
54.351.4886.427
Australia
61.2.9473.6800
Brazil
55.11.5502.7800
China
86.21.6247.1999
France
33.1.5695.6565
Germany
49.89.4612.2211
India
91.22.6768.7000
Italy
39.045.6209.240
Japan
81.3.3327.0011
W. L. Gore & Associates, Inc.
401 Airport Road • Elkton, MD 21921 • USA
Phone: 410.392.4440 (USA) • Toll free: 800.455.4684
Fax: 410.506.8749 • Email: protectivevents@wlgore.com
gore.com/protectivevents
adhesive vents
PolyVent
M12x1.5/
Metal Vent
*
M12x1.5 HA
M12x1.5
PMF100320
PMF100321
PMF100520
PMF100444
12.2 mm
12.2 mm
(0.472")
(0.472")
M10510-007
M10510-008
60 degrees
14.3 mm (0.562")
13.8 mm (0.543")
60 degrees
12.0 mm (0.472")
Korea
82.2.393.3411
Mexico
52.81.8288.1281
Netherlands
49.89.4612.2211
Scandinavia
46.31.706.7800
Singapore
65.6733.2882
Spain
34.93.480.6900
Taiwan
886.2.8771.7799
United Kingdom 44.1506.460123
USA
1.410.392.4440
Cross Section
All dimensions are in mm unless otherwise specified
PolyVent/M12x1
PolyVent/M12x1.5
PolyVent/M12x1.5 HA
Metal Vent/M12x1.5
According to Council
Directive 94/9/EC ATEX (95)
I M2 Ex e I
II 2G Ex e II
II 1D
Certificate available
upon request
Tolerances: DIN 16901/130 unless otherwise specified
FOR INDUSTRIAL USE ONLY.
Not for use in food, drug, cosmetic or medical device manufacturing,
processing, or packaging operations.
The optimal performance of any GORE
Protective Vent depends on how it is handled and incorporated into the final product.
®
This includes such elements as the device design, sealing method, and assembly method. While Gore is able to provide
general guidelines based upon its experience with GORE
for validating each product and its performance for its intended application. Contact a Gore technical sales associate today
for assistance in determining the best GORE
Protective Vent for your specific application.
®
® GORE and designs are trademarks of W. L. Gore & Associates, Inc. All rights reserved.
© 2010 W. L. Gore & Associates, Inc.
Screw-In Vents
ø17
GORE
Membrane
O-Ring
ø10.2
± 0.1
10 x 2
ø7.4
± 0.1
M12 x 1
ø17
GORE
Membrane
O-Ring 10 x 2
ø10.2
± 0.1
ø7.4
± 0.1
M12 x 1.5
ø18.2
GORE
Membrane
R0.4
O-Ring
10 x 2
ø10.15
M12 x 1.5
Protective Vents, the device manufacturer is ultimately responsible
®
Gehäusewand
Wall
Gehäusewand
Wa
Gehäusewan
Wa

Advertisement