Download Print this page

Ecco VIGILED II Installation And Operation Instruction page 2

Advertisement

ED0001x VigiLED II SERIES
EMC DIRECTIVE
This product complies with UN ECE R10 for electro-magnetic compatibility (emc)
To maintain compliance with this directive it is necessary that good installation practice is followed and a
qualified electrician should be consulted.
The VigiLED should be fitted using either the swivel bracket or surface mounted and orientated as shown with
the cable at the bottom.
1. For bracket mount, drill a 12.5mm (0.49") clearance hole in the required position. Remove the M12
nut and the M12 shakeproof washer from the bolt. Thread the cable through the centre hole in the
bolt, fix the VigiLED to the bracket using the M5 rubber washers (ensure that this washer is fitted
between the VigiLED and the bracket as shown in Fig.1.), and the M5 round cap screws. Fit the
assembly through the drilled hole, thread the M12 shakeproof washer and the M12 nut onto the
cable and fix to the bolt. The cable should be fitted with a suitable gland or grommet to ensure a
weather proof seal. Ensure that the wire ends of the cable and the end of the cable sheath where
connected to the vehicle battery supply are kept dry by protecting the termination against water
ingress or by sealing in some other way.
2. For surface mount, drill two 5.3mm (0.21") clearance holes in the panel 42mm (1.65") apart, for the
VigiLED to the panel using the M5 rubber washers and the M5 round cap screws in Fig.2. A hole for
the cable entry will be required and a suitable gland or grommet should be used. Ensure that the wire
ends of the cable and the end of the cable sheath where connected to the vehicle battery supply are
kept dry by protecting the termination against water ingress or by sealing in some other way.
3. Connect the cable to an appropriate power source (10-30 Volts DC); the total length of the connecting
cable from the power source to the light should be less than the 10m (32ft).
Connect the RED to +VDC (fuse@2A)
Connect the BLACK to the chassis ground
If two or more beacons are required to flash simultaneously then connect as follows:-
Connect the YELLOW wires of all the units together for synchronization
When the YELLOW wires of all the heads are connected together, the group 1 heads will flash in
phase (P1) or 180 degrees out of phase (P2) with group 2 heads based in the pattern selected. For
example, if the light heads in group 1 have flash pattern 2 selected and group 2 light heads have
pattern 3 selected, the group 1/group 2 heads will flash in a five flash alternating mode.