Electronics International EDC-33 Series Operating And Installation Instructions

Electronics International EDC-33 Series Operating And Installation Instructions

Engine data converter

Advertisement

Engine Data Converter
Engine Data Converter
Engine Data Converter
Engine Data Converter
Engine Data Converter
Operating and Installation Instructions
Operating and Installation Instructions
Operating and Installation Instructions
Operating and Installation Instructions
Operating and Installation Instructions
You must read this manual before installing or operating the instrument. This
manual contains warranty and other information that may affect your decision
to install this product and/or the safety of your aircraft.
Electronics International Inc.
Electronics International Inc.
Electronics International Inc.
Electronics International Inc.
Electronics International Inc.
63296 Powell Butte Hwy • Bend, OR 97701 •
63296 Powell Butte Hwy • Bend, OR 97701 •
63296 Powell Butte Hwy • Bend, OR 97701 •
63296 Powell Butte Hwy • Bend, OR 97701 •
63296 Powell Butte Hwy • Bend, OR 97701 •
EDC-33( )
EDC-33( )
EDC-33( )
EDC-33( )
EDC-33( )
II 0503161
Part #:
Part #:
Part #:
Part #:
Part #:
S/N:
S/N:
S/N:
S/N:
S/N:
(541) 318-6060 • Buy-EI.com
(541) 318-6060 • Buy-EI.com
(541) 318-6060 • Buy-EI.com
(541) 318-6060 • Buy-EI.com
(541) 318-6060 • Buy-EI.com
Rev A: 3/1/17 **
® ® ® ® ®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EDC-33 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Electronics International EDC-33 Series

  • Page 1 Part #: Part #: S/N: S/N: S/N: S/N: S/N: Electronics International Inc. Electronics International Inc. Electronics International Inc. Electronics International Inc. Electronics International Inc. ® ® ® ® ® 63296 Powell Butte Hwy • Bend, OR 97701 • 63296 Powell Butte Hwy • Bend, OR 97701 •...
  • Page 2 INSTALL THIS PRODUCT. tional Inc. for details. Electronics International Inc. is not liable or responsible for a pilot’s action or any situation that results in personal injury, property damage, missed commitments, lack of use of an aircraft or any expenses in-...
  • Page 3 Important Notice ***** MUST READ ***** Page 2 of 4 If the EDC is configured to monitor the aircrafts fuel tanks, the EDC must be calibrated to the aircraft fuel system and the EDC's accuracy must be verified before flying the aircraft. The accuracy and proper operation of each function monitored on the EDC should be verified before the aircraft is released for flight.
  • Page 4 DO NOT INSTALL THIS PRODUCT. DO NOT INSTALL THIS PRODUCT. This product may be returned for a refund. Contact Electronics International Inc. for details. Important Fuel Level Considerations: DO NOT RELY SOLELY ON THE FUEL LEVEL TRANSMITTED FROM THE EDC TO DETERMINE THE FUEL LEVELS IN THE AIRCRAFT.
  • Page 5 Important Notice, DO NOT INSTALL THIS PRODUCT. DO NOT INSTALL THIS PRODUCT. DO NOT INSTALL THIS PRODUCT. DO NOT INSTALL THIS PRODUCT. DO NOT INSTALL THIS PRODUCT. This product may be returned for a refund. Contact Electronics International Inc. for details.
  • Page 6: Table Of Contents

    Contents Warranty/Agreement------------------------------------------------------------------------- 1A 1.0 Operating Instructions ----------------------------------------------------------------- 1.1 System Description ----------------------------------------------------------------- 1.2 EDC Configurations --------------------------------------------------------------- Operation ------------------------------------------------------------------------- 1.4 Visual Status Indicator (VSI) ------------------------------------------------------- 2.0 Installation Instructions ----------------------------------------------------------------- 2.1 Install the EDC -------------------------------------------------------------------- 2.2 Setup and Calibration ------------------------------------------------------------- 2.3 Periodic Maintenance -------------------------------------------------------------- 4 2.4 Continued Airworthiness ---------------------------------------------------------- 2.5 Inspection Intervals ---------------------------------------------------------------- 2.6 Service Life ------------------------------------------------------------------------ 4...
  • Page 7: Warranty/Agreement

    DO NOT Install This Product This Product This Product..You may return the product for a refund, contact Electronics International Inc. for details. This Product This Product 2. Electronics International Inc. is not liable or responsible for a pilot’s action or any situation that results in...
  • Page 8 Electronics International Inc. 8. Electronics International Inc. is not liable for expenses incurred by the customer or installer due to factory updates, modifications, improvements, changes, or any other alterations to the product that may affect the form, fit, function or operation of the product.
  • Page 9: Operating Instructions

    By processing the raw sensor data via the EDCxx-( ) the workload of the display or logging unit is significantly reduced. The “xx–( )” in the model number is filled in by Electronics International with numbers and/or letters that identify the EDC-33xx-( )’s configuration. Configurations are setup at Electronics International before the...
  • Page 10: Operation

    1.3 Operation: The EDC only has one operating mode. On power-up the unit performs a self test and within one second the Visual Status Indicator (VSI) will start flashing green (if no errors are detected). 1.4 Visual Status Indicator (VSI): The light on the top of the EDC is a Visual Status Indicator (VSI).
  • Page 11: Installation Instructions

    (the same as the routed wire) crimp a pin onto the wire and perform a pull test. Test a wire from each group of different wire material. The wire retention strength for Electronics International’s D- Sub pins are approximately: 20 ga Copper Wire –...
  • Page 12: Setup And Calibration

    2.2 Setup and Calibration: The EDC-33xx-( ) unit will be setup and calibrated at Electronics International’s manufacturing facility to a specific set of sensors applicable for the intended installation. When the unit is ordered, a worksheet provided (by the customer) will be required, listing the calibration output signal levels for each of the sensors to be monitored.
  • Page 13: Sae Standards, Tsos And Mps

    This article is an incomplete TSO article, requiring engine sensors and a display system to form a complete instrument system. 2.8 SAE Standards, TSOs and MPS: The EDC-33xx-( ) articles carry the following TSO authorization: TSO-C43c, Temperature TSO-C44c, Fuel Flow TSO-C45b, Manifold Pressure TSO-47a,...
  • Page 19: Sample Wiring Diagram

    3.0 Sample Wiring diagram DB-37 Back View, Wire Side DB-37 (421-0338-00) Pin (421-0301-00) Btm Connector Top Connector Mid Connector DB-37 DB-37 Pulse 6 <1 to >80K Hz, Trig = .386V/0V 21.5mV / 11mV Pulse 3 <1 to >80K Hz, Trig = .386V/0V Power Power In, (9 to 65 Volts).
  • Page 21: Do-160G Environmental Qualification Form

    4.0 DO-160G Environmental Qualification Form...
  • Page 25: Specifications / Features

    Specifications / Features 1022161 Rev. New: 10/22/16 Models: Models: Models: Models: Models: EDC-33PW, EDC-33ST and EDC-33SP Weight: Weight: Weight: 1.0 Lbs. Weight: Weight: Environmental: Environmental: Environmental: Environmental: Environmental: Designed and Tested to TSO (DO-160G), See EQF. Software: Software: Software: Designed and Documented to TSO (DO-178C, Level C) Software: Software: Minimum Performance Standards:...

This manual is also suitable for:

Edc-33spEdc-33pwEdc-33st

Table of Contents