    PIP 1648MSX 2KVA 48V 110/120V Output SOLAR INVERTER CHARGER User Manual *with built-in 60A MPPT VERSION 1.0...
  • Page 2: Table Of Contents

    Table of Contents ABOUT THIS MANUAL ........................1 Purpose ..............................1 Scope ..............................1 IMPORTANT SAFETY INSTRUCTIONS ..................... 1 INTRODUCTION ..........................2 Features ............................... 2 Basic System Architecture ........................2 Product Overview ..........................3 INSTALLATION ..........................4 Unpacking and Inspection ........................4 Preparation ............................
  • Page 3: About This Manual

    ABOUT THIS MANUAL Purpose This manual describes the assembly, installation, operation and troubleshooting of this inverter/charger. Please read this manual carefully before installations and operations. Keep this manual for future reference. Scope This manual provides safety and installation guidelines as well as information on tools and wiring. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS–...
  • Page 4: Introduction

    INTRODUCTION This is a multi-functional inverter/charger, combining the functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portability. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, priority setting for AC/solar charger, and acceptable input voltage setting to suit different applications.
  • Page 5: Product Overview

    Product Overview 1. LCD display 2. Status indicator 3. Charging indicator 4. Fault indicator 5. Function buttons 6. Power on/off switch 7. AC input 8. AC output 9. PV input 10. Battery input 11. Circuit breaker 12. RS232 communication port 13.
  • Page 6: Installation

    INSTALLATION Unpacking and Inspection Before installation, please inspect the inverter/charger. Be sure that nothing inside the package is damaged. You should have received the following items inside the package:  The inverter/charger x 1  User manual x 1  Communication cable x 2 (RS232 cable and RS485 cable) ...
  • Page 7: Grounding

    Grounding CAUTION: For safety, it’s requested to connect the device to the ground first. Proper grounding can not only remove the unwanted “electrical noise” but can even make surge protection device work better. Please refer to the typical requirement in the table below as required grounding cables. Suggested cable requirement for grounding Color Gauge...
  • Page 8: Ac Input/Output Connection

    WARNING: Shock Hazard Installation must be performed with care due to high battery voltage in series. CAUTION!! Do not place anything between the flat part of the inverter/charger terminal and the ring terminal. Otherwise, overheating may occur. CAUTION!! Do not apply any anti-oxidant substance on the terminals before the terminals are connected tightly.
  • Page 9: Pv Connection

    WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the inverter/charger. 4. Then, insert AC output wires according to polarities indicated on terminal block and fasten the terminal screws. Be sure to connect PE protective conductor ( ) first.
  • Page 10: Final Assembly

    2. Open circuit Voltage (Voc) of PV modules should be higher than the minimum voltage of the battery. Solar Charging Mode Max. PV Array Open Circuit Voltage 145Vdc PV Array MPPT Voltage Range 60~115Vdc Min. battery voltage for PV charge 34Vdc Please follow the steps below to implement PV module connection: 1.
  • Page 11: Communication Connection

    Communication Connection Please use supplied RS232 cable to connect to the inverter/charger and PC. Insert bundled CD into a computer and follow the on-screen instructions to install the monitoring software. For the detailed software operations, please check user manual of software inside the CD. There is one RS485 port reserved for communication with external battery management system.
  • Page 12: Operation

    OPERATION Power ON/OFF Once the inverter/charger has been properly installed and the batteries are connected well, simply press On/Off switch (located on the right corner of the top panel) to turn on the inverter/charger. Operation and Display Panel The operation and display panel, as shown in the chart below, are on the front panel of the inverter/charger. It includes three indicators, four function keys and an LCD display, indicating the operating status and input/output power information.
  • Page 13: Lcd Display Icons

    Function Keys Function Key Description To exit setting mode To go to previous selection DOWN To go to next selection ENTER To confirm the selection in setting mode or enter setting mode LCD Display Icons Icon Function description Input Source Information Indicates the AC input.
  • Page 14 Bottom two bars will be on and the other two bars will Constant Voltage 50% ≤ battery level < 75% flash in turns. mode Battery level ≥ 75% Bottom three bars will be on and the top bar will flash. In floating mode, batteries are fully charged.
  • Page 15: Lcd Setting

    LCD Setting After pressing and holding the ENTER button for 3 seconds, the inverter/charger will enter setting mode. Press “UP” or “DOWN” button to select setting programs. And then, press “ENTER” button to confirm the selection or ESC button to exit. Setting Programs: Program Description...
  • Page 16 If selected, acceptable AC input voltage range will be within 95-140VAC. Saving mode disable If disabled, no matter connected load (default) is low or high, the on/off status of inverter output will not be effected. Power saving mode enable/disable Saving mode enable If enabled, the output of inverter will be off when connected load is pretty low or not detected.
  • Page 17 Battery fully charged Setting voltage level back to battery mode when selecting “SBU priority” or 54V (default) “Solar first” in program 01. If this inverter/charger is working in Line, Standby or Fault mode, charger source can be programmed as below: Solar first Solar energy will charge battery as first priority.
  • Page 18 Return to default If selected, no matter how users display screen switch display screen, it will (default) automatically return to default display screen (Input voltage /output Auto return to default voltage) after no button is pressed for display screen 1 minute. Stay at latest screen If selected, the display screen will stay at latest screen user finally...
  • Page 19: Display Setting

    Display Setting The LCD display information will be switched in turns by pressing “UP” or “DOWN” key. The selectable information is switched as below order: input voltage, input frequency, PV voltage, MPPT charging current, MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, main CPU Version and second CPU Version.
  • Page 20 Battery voltage=50.5V, discharging current=1A Battery voltage/ DC discharging current Output frequency=60Hz Output frequency Load percent=70% Load percentage When connected load is lower than 1kVA, load in VA will present xxxVA like below chart. Load in VA When load is larger than 1kVA (≧1KVA), load in VA will present x.xkVA like below chart.
  • Page 21 When load is lower than 1kW, load in W will present xxxW like below chart. Load in Watt When load is larger than 1kW (≧1KW), load in W will present x.xkW like below chart. Main CPU version 00014.04 Main CPU version checking Secondary CPU version 00003.03 Secondary CPU version checking...
  • Page 22: Operating Mode Description

    Operating Mode Description Operation mode Description LCD display Charging by utility. Standby mode / Power saving mode Note: *Standby mode: The inverter/charger is not turned Charging by PV energy. No output is supplied by the on yet but at this time, the inverter/charger but it still inverter/charger can charge can charge batteries.
  • Page 23: Fault Reference Code

    Fault Reference Code Fault Code Fault Event Icon on Fan is locked when inverter/charger is off. Over temperature Battery voltage is too high Battery voltage is too low Output short circuited or over temperature is detected by internal converter components. Output voltage is abnormal.
  • Page 24: Specifications

    SPECIFICATIONS Table 1: Line Mode Specifications INVERTER MODEL 2KVA 48V Plus Input Voltage Waveform Sinusoidal (utility or generator) Nominal Input Voltage 110/120Vac 95Vac± 7V (UPS) Low Loss Voltage 65Vac± 7V(Appliances) 100Vac± 7V(UPS); Low Loss Return Voltage 70Vac± 7V(Appliances) High Loss Voltage 140Vac±...
  • Page 25 Table 2: Inverter Mode Specifications INVERTER MODEL 2KVA 48V Plus Rated Output Power 2KVA/1.6KW Pure Sine Wave Output Voltage Waveform ± 5% Output Voltage Regulation 110/120VAC 60Hz or 50Hz Output Frequency Peak Efficiency Overload Protection 5s@≥150% load; 10s@110%~150% load 2* rated power for 5 seconds Surge Capacity Nominal DC Input Voltage 48Vdc...
  • Page 26 Table 3: Charging Mode Specifications Utility Charging Mode INVERTER MODEL 2KVA 48V Plus Charging Current (UPS) 5/10A @ Nominal Input Voltage Flooded Battery 58.4 Bulk Charging Voltage AGM / Gel Battery 56.4 Floating Charging Voltage 54Vdc Overcharge Protection 60Vdc Charging Algorithm 3-Step Battery Voltage, per cell Charging Current, %...
  • Page 27: Troubleshooting

    TROUBLESHOOTING Problem LCD/LED/Buzzer Explanation / Possible cause What to do Inverter/charger LCD/LEDs and buzzer shuts down will be active for 3 The battery voltage is too low 1. Re-charge battery. automatically seconds and then (<1.91V/Cell) 2. Replace battery. during startup complete off.