Soniprep 150 Plus Ultrasonic Disintegrator User Manual Please read this before use...
Page 2
ELECTRICITY SUPPLIES: Voltage and frequency MSE (UK) Ltd electrical apparatus is offered and labelled for one or for a choice of two or more voltage ranges and, where necessary, different frequencies of mains supply. MSE (UK) Ltd does not accept any...
Page 3
Please dispose of centrifuge carefully! MSE adheres to the WEEE (Waste Electrical and Electronic Equipment) directive, which ensures that all electrical equipment is disposed of carefully with consideration to the environment. As a responsible manufacturer of quality laboratory equipment, MSE will recycle your equipment once its life expires and therefore reduce the amount of waste electrical equipment that is sent to landfill.
Page 4
Read This Before Use! THIS MACHINE HAS BEEN FITTED WITH A NEW THUMB TURN LOCK. PLEASE OPERATE THIS MACHINE ONLY WHEN THE DOOR IS LOCKED AND THE LATCH IS FULLY ENGAGED TO ENSURE THE DOOR IS FULLY LATCHED, TURN THE THUMB WHEEL FULLY CLOCKWISE TILL THE FLATS ON THE LOCK ARE SITTING HORIZONTALLY THIS STOPS ANY SOUND WAVES FROM LEAVING THE SOUND PROOFED CHAMBER PLEASE TURN THE SONIFICATION OFF BEFORE OPENING THE DOOR.
Page 5
EC DECLARATION OF CONFORMITY According to ISO 17050-1, ISO/IEC 17050-2 Type of device: Ultrasonic Disintegrator Product name: Soniprep 150 Plus SONIPREP-EXP-BUNDLE SONIPREP-9.5-BUNDLE Model numbers: SONIPREP-19-BUNDLE EC guidelines and standards: 73/23/EEC, BS EN 61010-1, BS EN 61010-2-020 89/336/EEC, 92/31/EEC, 93/68/EEC, BS EN 61000-6-1, BS EN 61000-3-2, BS EN 61000-...
Page 6
Thank you for buying an MSE Soniprep 150 Plus. Please read this operating manual before using your Soniprep; it will provide you and your colleagues with useful information on all aspects of the equipment. As our customer, we should like to ensure that you are totally satisfied at all times.
Page 7
Terms and Conditions We hope that you do not have the need to use the extensive warranty cover that MSE (UK) Ltd extends to you. However should you have a problem, our prompt response is greatly helped if you have filled in and posted the pre-paid Warranty Registration Card supplied with your new equipment.
Page 8
ELECTRICITY SUPPLY Before connecting this apparatus to the electricity supply, check the information given on the apparatus rating plate and ensure that: A) Your supply is single phase AC (alternating current) of the stated frequency with the neutral nominally at earth potential. B) Your supply voltage is within the stated range.
INTRODUCTION INTRODUCTION The Soniprep 150 Plus Ultrasonic Disintegrator is a self-contained unit designed for convenient tabletop operation. It incorporates an acoustic cabinet, which reduces externally audible noise and ultrasound to a safe level. A transparent door allows observation of the sample during sonication. The apparatus is factory adjusted to the user's electrical supply voltage and frequency.
Page 11
INTRODUCTION Front PROBE CONTROL PANEL SAMPLE CLAMP DOOR LOCK PLATFORM Rear PROCESS TIMER CONNECTION (POWER) VESSEL CONNECTION WATT METER (INLET/OUTLET) CONNECTION PROCESS TIMER CONNECTION (CONTROL) FUSES MAINS CONNECTION...
INTRODUCTION Control Panel Description The control panel is situated on the right hand side of the unit. A brief description of their individual functions follows: Amplitude Meter - The meter is calibrated in microns and monitors the probe amplitude, that is, the actual movement peak-to-peak that is taking place at the transducer/probe interface.
Page 13
INTRODUCTION AMPLITUDE INCREASE AMPLITUDE DECREASE TIME INCREASE TIME DECREASE POWER ON POWER OFF Control Panel...
Location of the Instrument and Electrical Connections Place the Soniprep 150 Plus on a suitable table or bench and ensure that at the rear of the instrument is at least 50mm (2’) away from the wall to allow...
Note: Probes are specially designed to suit the Soniprep 150 Plus models and are tuned to 23 KHz. Exponential Microprobe This probe has been specifically designed for the treatment of small quantities of sample, up to 5ml.
PROCESSING SAMPLES Sometimes, when the solution is thoroughly aerated, the usual process noise from the beaker or test tube will stop, i.e. no buzz or vibration will be heard. Again, this is because there is little transfer of energy. When these conditions occur, turn the power off for a few seconds and set the probe deeper.
PROCESSING SAMPLES Testing Probe Performance The following test should be carried out so that users may monitor the performance of each probe. Measure the temperature rise obtained at maximum power after 5 minutes with the following volumes of chilled water (i.e. below 10°C). Probe Volume of Chilled Water Exponential...
As there is sufficient force generated by the Soniprep 150 Plus to fracture or shatter glass, the probe tip must not be allowed to come in contact with, or come close to, the bottom of the vessel.
PROCESSING SAMPLES When fitting sealing caps, the air pressure which may have built up can be released by lifting the edge of the cap slightly. The caps are manufactured from a material which is suitable for autoclaving. When treating samples in any of the test tubes the temperature of the suspension will rise, especially if the quantities of the material being treated are small.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Misuses include: a) Impeding air flow. b) Incorrect positioning of the probes with respect to the transducer (see section 2.4). c) Lack of probe maintenance (see section 2.5). d) Probe in liquid (foaming) Manual Control a) Plug the 3 pin plug into the power outlet. Switch the green supply rocker switch to its ‘ON’...
Page 21
OPERATING INSTRUCTIONS USE THE CONTROL SWITCHES ON THE PROCESS TIMER ONLY WHILST THE PROCESS TIMER IS PLUGGED INTO THE SONIPREP APART FROM TURNING THE SONIPREPON AT THE MAINS AND SETTING UP THE AMPLITUDE, THE PROCESS TIMER SHOULD BE USED TO CONTROL THE SONIPREP ONLY.
CLEANING AND FAULT FINDING Use a damp cloth for cleaning outside. If internal chamber etc. requires disinfecting the following fluids may be used: TERMINEX 2 (Available from Arrow Chemicals Ltd) VIRKON (Available from Antec International) These cleaning agents if used as instructed by the manufacturer should not be harmful to this product, or accessories supplied for use with this product.
SPECIFICATIONS SPECIFICATIONS Specification for Soniprep MSS150.CX3.5 MSS150.CX3.1 HEIGHT (mm) WIDTH (mm) DEPTH (mm) WEIGHT (Kg) 18.7 18.7 PROBE FREQUENCY (KHz) VOLTAGE (volts) 220/240 MAINS FREQUENCY (Hz) 50/60 FUSES (anti-surge) 2amp 4amp MAX. NOISE LEVEL (dB) WITH DOOR CLOSED MAX. NOISE LEVEL (dB) WITH DOOR OPEN Specification for Process Timer 46222.5019...
SPECIFICATIONS OPTIONAL ACCESSORIES FOR THE SONIPREP 150 PLUS PART DESCRIPTION NUMBER 46222-5019 Process Timer Unit 38121-114A Exponential Microprobe, end diameter 3mm 38121-1154 Solid Probe, end diameter 9.5mm 38121-1169 Solid Probe, end diameter 19mm 48535-1011 Batch Treatment Vessel 46222-5020 Wattage meter...
Page 25
Meet the rest of the family Brand new generation of centrifuges MICROCENTAUR R Refrigerated Micro Centrifuge 18000 rpm Maximum speed Maximum RCF 24270 xg Maximum Volume 24 x 2/1.5ml HARRIER General Purpose Centrifuge Ambient and Refrigerated Swing Out / Fixed Angle / Microplate Maximum speed 18000 rpm Maximum RCF...