Clip Installation And Adjustment Of The Aps System - Cedes APS Installation And Operation Manual

Absolute positioning system
Table of Contents

Advertisement

APS
Alignment
Alignment lEDs
left (-) /
Signaling limits lED [mm]
right (+)
Cannot read
tape
Too left
Slightly left
Position OK
Slightly right
Too right
Cannot read
tape
Table 6:
Alignment indication from the sensor to the code tape and vice versa (at 105 mm distance between APS sensor and code tape)
Note: The limits are approximate values, they differ slightly from sensor to sensor (±0.5 mm).
6.4
Clip installation and adjustment of
the APS system
The clips serve the following functions:
• Guide clip:
- Guides/aligns the code tape along the optical axis of
the APS sensor.
- Prevents the code tape from swinging and twisting.
• Position indicator clip:
- Guides/aligns the code tape along the optical axis of
the APS sensor.
- Prevents the code tape from swinging and twisting.
Depending on the downstream processing unit, the
APS sensor can detect the exact position of the position
indicator clip. The downstream processing unit can use
this information
- to detect doors and floors.
- to compensate for building shrinkage.
6.4.1 Installation of the guide clip
1. Whenever handling the code tape, use cut protection
gloves to prevent potential injury.
2. Insert the code tape into the clip guide rails (Figure
44).
figure 44: Guide clip is inserted (left) and turned 90º clockwise
3. Turn the clip by 90º.
4. Fix the clip using appropriate screws and ring washer.
20
Out of reading range
Out of
to -11.0
reading range
-11.0 to -4.0
-4.0 to +4.0
+4.0 to +11.0
Out of
+11.0 to
reading range
Out of reading range
Alignment Alignment lEDs
Near (-) /
Signaling limits lED
far (+)
Cannot read
tape
Too near
Slightly too
near
Position OK
Slightly too
far away
Too far away
Cannot read
tape
6.4.2 Installation of the position indicator
clip
1. For all operations with the code tape use cut
protection gloves to prevent of cutting.
2. Insert code tape in the clip guide rails (Figure 45).
figure 45: APS position indicator clip is inserted (left) and turned
90º clockwise
3. Turn the clip by 90º.
4. Fix the clip using appropriate screws and ring washer.
5. The recommended distance between the clips
depends on the nominal speed of the elevator and
other factors such as airflow in the elevator shaft. A
typical value is 3 - 5 m. It is important that enough
clips are used to prevent the code tape from twisting.
English
Out of reading range
Out of
to -13.0
reading range
-13.0 to -7.0
-7.0 to +7.0
+7.0 to +13.0
Out of
+13.0 to
reading range
Out of reading range