    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Table of Contents System KMP-V.......................3 Overview......................3 Monitoring......................4 Max.Alarm......................4 Seepage Alarm....................4 System Test......................4 Operation .......................5 Operating Modes....................6 Manual Phase Switching..................6 Automatic Phase Switching (External Input)...........6 Automatic Phase Switching (PIR) ..............6 Special Functions ....................6...
  • Page 3: System Kmp-V

    110101 func. spec. 160926 Doc.No. 417106 Revision 170823 System KMP-V DanTaet System KMP-V is a leakage protection system for supply water installations.  The system comprises a Kamstrup ultrasonic water meter MULTICAL 62, a leakage detection unit KMP-V and an electrically actuated cut-off valve. The valve is connected to the KMP-V via a DIN plug, and the water meter is connected via a data link to the KMP-V, which fetches flow readings from the water meter.
  • Page 4: Monitoring

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Monitoring Max.Alarm If water is discharged continuously until the set limit is exceeded, a Max. Alarm is issued, and the installation is cut off. The flow above which consumption is considered a discharge is adjustable, permitting adaptation of the system to the various minimum flows of different installations.
  • Page 5: Operation

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Operation The KMP-V system is operated from the front panel, which is equipped with six indicators and four buttons. Inside the front panel sits a buzzer which emits a short ’click’ sound on legitimate key operations, a longer ’boo’...
  • Page 6: Operating Modes

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Operating Modes Switching between monitoring phases is done manually or automatically in one of two ways. Manual Phase Switching Manual Phase Switching is done using the front panel ’Holiday’ button. Holiday Mode (Low Phase) is indicated by ’Consumption’...
  • Page 7: Normal Operation Without Disturbance

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Function Description / Operating Modes When operating, the system may be in one of five different operating modes • Normal operation without disturbance • Normal operation with disturbance •...
  • Page 8: Normal Operation

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Normal Operation ● ○ ● Status Status Status ○ ○ ○ Data Data Data ● ● ● Valve Valve Valve ○ ○ ○ Max.Alarm Max.Alarm Max.Alarm ☼...
  • Page 9: Disturbance

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 ● ● Disturbance Status Status ○ ○ Data Data ● ● Valve Valve ○ ○ Max.Alarm Max.Alarm ○ ○ Seepage Alarm Seepage Alarm ○ ● Consumption...
  • Page 10: Leakage Alarm Condition

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Leakage Alarm Condition ○ ○ Status Status ○ ○ Data Data ● ● Valve Valve ☼ ● Max.Alarm Max.Alarm ○ ○ Seepage Alarm Seepage Alarm ○...
  • Page 11: System Error Condition

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 System Error Condition A critical system error has occurred, and the leakage protection system is inoperative. The water supply is unimpeded. The system is in immediate need of servicing.
  • Page 12: Liquid Sensor Wet

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Liquid Sensor wet ● ● Status Status ○ ○ Data Data ● ● Valve Valve ☼ ● Max.Alarm Max.Alarm ☼ Seepage Alarm ● Seepage Alarm ○...
  • Page 13: Liquid Sensor Defective

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Liquid Sensor defective ☼ ● Status Status ○ Data ○ Data ● ● Valve Valve ○ ○ Max.Alarm Max.Alarm ● ● Seepage Alarm Seepage Alarm ○...
  • Page 14: External Control

    Doc.No. 417106 Revision 170823 External Control System KMP-V features two digital inputs which are activated by shorting their terminals using e.g. a relay contact or a panel switch. The open terminals carry 12Vdc. Short circuit current is < 5mA. The functions invoked by activating the digital inputs are determined by internal jumper settings.
  • Page 15: Digital Outputs

    Doc.No. 417106 Revision 170823 Digital Outputs System KMP-V features three optoisolated digital, passive pulll-down outputs with a common reference potential (GND) in connector J6. Terminal J6.1 supplies a synthesized meter impulse from the water meter. The impulse value is selected in jumper row F positions 6-8.
  • Page 16: Liquid Sensor Option

    Revision 170823 Liquid Sensor Option System KMP-V accepts one or two liquid sensors type LS-X after installation of interface ILS-C. The LS-X liquid sensor responds to a water aggregation touching both its electrodes, and can hence cause the control box to issue an alarm and if desired close the cut-off valve when wet.
  • Page 17: Liquid Sensor Interface Ils-C

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Liquid Sensor Interface ILS-C. The system can be extended by an ILS-C module, accomodating up to two Liquid Sensors LS-X. Continuous monitoring for: 1: Dry condition 2: Wet condition Alarm: "Liquid Sensor Wet"...
  • Page 18: Checking And Setting The Clock

    Revision 170823 Checking and Setting the Clock System KMP-V is equipped with a real-time clock governing the valve tightness check. The clock automatically selects Daylight Savings Time as appropriate. Slight inaccuracies may accumulate over time; therefore the clock may be checked and set as...
  • Page 19: Checking And Setting The Free Time

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Checking and setting the Free time The duration for which the discharge monitor is suppressed after activating the ’Unlimited’ key can be set from one to eight hours from the front panel.
  • Page 20: Plumbing

    230Vac KMP-V MULTICAL    From Utility To Consumer Supply Water Installation System KMP-V Legend: Cut-off Valvel Key Switch 230Vac Flow meter Page 20 of 26...
  • Page 21: Socket And Gland Identification

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Socket and Gland Identification KMP-V A: 230Vac from mains B: 24Vac to MULTICAL C: LS-X Liquid Sensor, Alarm Relay D: Alarm Relay, PIR sensor E: Data Link to MULTICAL...
  • Page 22: Electrical Installation

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Electrical Installation The valve cable terminates in a DIN plug which connects to the KMP-V socket. Connection of the KMP-V to mains, external controls, communication and remote alarm systems is shown is illustrated here.
  • Page 23: Setting The Monitoring Function

    Revision 170823 Setting the Monitoring Function System KMP-V is delivered with pre-set default factory settings, but may be easily adapted to the actual installation by the relocation of jumpers on the circuit board mounted in the lid of the enclosure.
  • Page 24: Jumper Row A-D: Monitoring Parameters

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Jumper Settings Jumper row A-D: Monitoring Parameters Position A: Max Dischg(H) B: Cutoff (L) C: Idle Per. D: Tolerance Classic PSALM 10 l 10 l/h 10 s...
  • Page 25: Seepage Tolerance

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 Seepage Tolerance Seepage Tolerance in litres vs. jumper setting row D and meter size. Meter Imp/l 0.01 0.02 0.05 0.017 0.033 0.083 0.167 0.333 0.833 1.67 3.33...
  • Page 26: Eu Declaration Of Conformity

    DanTaet a/s User Manual System KMP-V 110101 func. spec. 160926 Doc.No. 417106 Revision 170823 EU Declaration of Conformity Page 26 of 26...

Table of Contents