Advertisement

Quick Links

SKDP03-T
Cable Kit
10 M
Mounting instructions

Advertisement

Table of Contents
loading

Summary of Contents for Samcon SKDP03-T

  • Page 1 SKDP03-T Cable Kit 10 M Mounting instructions...
  • Page 2: Table Of Contents

    Support / contact ....................10 Notes ........................11 Table of Figures Figure 1.1 – Content of the Cable Kit SKDP03-T .............. 3 Figure 2.1 – Cable cross section ..................4 Figure 2.2 – Stripped cable and bare shielding ..............4 Figure 2.3 –...
  • Page 3: Content Of The Cable Kit Skdp03-T

    8 x wire-end ferrules (e)  1 x documentation Figure 1.1 – Content of the Cable Kit SKDP03-T Installing and wiring (connection to ExTB-3) The following chapter describes the configuration of the cable, how to insert it into the terminal box ExTB-3 and how to connect it.
  • Page 4: Customization Of The Cable Connection

    Customization of the cable connection Looking at the digital system cable’s cross section, the following elements are visible: Outer sheath (jacket) (1) Filling threads (2) Power elements (3) Copper wire shielding (4) Blank shielding wire (5) Shielding foil (6) Isolation foil (7) Data elements (8) Figure 2.1 –...
  • Page 5: Figure 2.4 - Shrinking Tube Over Twisted Shielding Braid

    Cut the yellow-green shrinking tube to match the length of the shielding braid. Now shrink-fit the shrinking tube by using a hot air blower. Figure 2.4 – Shrinking tube over twisted shielding braid After this, put the black shrinking tube over all cables and the shielding and shrink it. Remove approx.
  • Page 6: Insertion Into Ex-E

    Insertion into Ex-e Through the middle cable gland, insert the prepared cable (q.v. chapter 2. 1) into the terminal box ExTB3. Connecting the cable to the clamps Corresponding to the color code of the already connected camera cable, also the cables of the cable kit are connected so that the colors match.
  • Page 7: Mounting The Barrier Gland (Insertion Into Ex-D)

    Mounting the barrier gland (insertion into Ex-d) Components of the barrier gland Screw connection 1 Outer seal nut (red) Compound Tube Screw connection 2 Spacer Figure 3.1 – Components of the barrier gland Configuration of the connection Strip 25 cm off the green jacket (q.v. chapter 2.1, figure 2.1 (1)) and cut off the isolation foil (7).
  • Page 8: Kneading

    Kneading Put on the supplied protective gloves and mix both components of the two-part expoxy compound until it is pliable and of an even color (minimum mixing temperature 10°C / 50°F). Untwist the cable cores and apply the compound around them over a length of 40 mm so that there is compound around each individual cable core (zigzag).
  • Page 9: Connecting The Rj 45 Plug (Ex-D Or Non-Ex)

    Connecting the RJ 45 plug (Ex-d or non-ex) Strip off 25 cm of the cable isolation as described in chapter 3.1. Please make sure not to damage the isolation foil (7). The plug is connected according to EIA/TIA-568B (q.v. attached sketch). The cables of the same color will be put through the applicable opening and then cut off flush at the front.
  • Page 10: Connecting The Power Channel (24Vdc)

    Cable distribution: Black +24 VDC Blue 0 VDC Green-yellow to earth potential Support / contact If you have any questions or if you need our support please contact us at: Mail: support@samcon.eu Tel.: +49 6426 9231-0 https://www.samcon.eu/en/contact/ Doc.-ID: CableKitSKDP03-T_10M_MountingInstructions_rev.00.docx, Seite 10 von 12...
  • Page 11: Notes

    Notes Doc.-ID: CableKitSKDP03-T_10M_MountingInstructions_rev.00.docx, Seite 11 von 12...
  • Page 12 Schillerstrasse 17, 35102 Lohra-Altenvers www.samcon.eu, info@samcon.eu fon: +49 6426 9231-0, fax: - 31 Doc.-ID: CableKitSKDP03-T_10M_MountingInstructions_rev.00.docx, Seite 12 von 12...

Table of Contents