Phoenix DryRod TYPE 50A SERIES Operating Instructions Manual

Portable electrode stabilization ovens

Advertisement

I.

OPERATING INSTRUCTIONS FOR TYPE 50A SERIES

MODELS 7, 9, 10, 11, 14, 15, & 17 PORTABLE ELECTRODE STABILIZATION OVENS
TYPE 50A MODEL 14
Three Wire Grounded Circuit:
120 Volts AC/DC
Temperature: 300°F Average
(stabilized temperature)
Heating Element: Ring Type, 350 Watts, 120 Volts
Type 50A Model, 9, 10, 11, 14, & 17 120V (AC/DC)
Plug power cord into suitable 120 Volt AC or DC power
source.
Type 50A Model 7 & 15, 240V (AC Only)
Plug power cord into suitable 240 Volt AC (Only) power
source.*
ELECTRODE HOLDING
1. Open lid of box and allow approximately 20 minutes
warm-up to drive out any retained moisture.
2. Place only dry electrodes within box. Keep lid closed
but unlatched while plugged into powered receptacle.
*Caution* - To avoid oven damage, never place oven in contact with welding current.
All wiring should be done by licensed electricians in accordance with State & Local codes plus NEC (National Electric
Code) Standards. Improper installation or use may result in serious injury. Always remove oven from power source
before troubleshooting or repairing.
II.
OVEN FAILS TO OPERATE - NO HEAT
1. If oven will not heat, check power supply.
2. Check plug at outer end of power cord. Check com-
plete power cord for continuity. If defective, replace cord
assembly.
3. Disconnect wires from heating element and check
heating element for continuity (access through top of
Electrode Stabilizing
DryRod
Heating Element: Ring Type, 350 Watts, 240 Volts
ELECTRODE STORAGE
3. When your job is done, the oven should remain con-
nected to its power source. If it becomes necessary to
disconnect from power, keep the lid closed and latched
to provide sealed storage of unused electrodes.
4. Your DryRod® oven has been preset at the factory for
optimum temperature control. The sealed thermostat is
not adjustable, but easily replaced if it fails. Average
stabilized temperature of the oven is 300°F with a full
load (average 250°F empty). A parts list and wiring dia-
grams are printed on the reverse side for your conven-
ience.
*Warranty is void if used with D.C. power source
**CAUTION**
oven). If defective, replace elements.
4. On type 50A ovens check thermostat for continuity at
ambient temperature (access through top of oven). If
defective, replace thermostat.
OVEN OPERATES - OVERHEATS
1. Check thermostat operation as in number 5 (Oven
Fails To Operate - No Heat).
Ovens
TYPE 50A MODEL 15
Three Wire Grounded Circuit:
240 Volts AC (Only) *
Temperature: 300°F Average
(stabilized temperature)
®
N5430400P-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DryRod TYPE 50A SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix DryRod TYPE 50A SERIES

  • Page 1 Electrode Stabilizing DryRod ® Ovens OPERATING INSTRUCTIONS FOR TYPE 50A SERIES MODELS 7, 9, 10, 11, 14, 15, & 17 PORTABLE ELECTRODE STABILIZATION OVENS TYPE 50A MODEL 15 TYPE 50A MODEL 14 Three Wire Grounded Circuit: Three Wire Grounded Circuit: 240 Volts AC (Only) * 120 Volts AC/DC Temperature: 300°F Average...
  • Page 2 Phoenix International, Inc. warrants its products against defects in material and workman- This warranty applies only to Products sold by Phoenix International, Inc. and specifical- ship. The company will, at its discretion, repair or replace any properly installed Phoenix ly excludes installation or de-installation labor, transportation, or equipment of another International manufactured product which fails under normal operating conditions within manufacturer used in conjunction with Phoenix International products.
  • Page 3 Electrode Stabilizing DryRod ® Ovens OPERATING INSTRUCTIONS FOR TYPE 50 SERIES PORTABLE ELECTRODE STABILIZATION OVENS Type Part # De s cription - (All 50-60 cycle s ) Temp. Range ** 1205410 120V AC* @ 350 w atts w / 10' Grounded HD cord 300°F (149°C) Pr e s e t 50B/120 Sealed Thermostat...
  • Page 4 "Revised Guide To Electrode supply cord. When used with a grounded receptacle, these Storage" (available from Phoenix International, Inc.) may be ovens meet all local electrical code requirements and are used as an indication of approximate temperatures for use U.L.
  • Page 5 **CAUTION** All wiring should be done by licensed electricians in accordance with local codes. Improper installation or use may result in serious injury. Always remove oven from power source before troubleshooting or repairing. TROUBLESHOOTING - TYPE 50 OVENS III. OVEN FAILS TO OPERATE - NO HEAT 1.
  • Page 6 Note Always replace BOTH heating elements if one fails. (Two are required for each oven.) Replacement elements are sold in sets of (2) each only. Phoenix International, Inc. 8711 West Port Avenue • Milwaukee, WI 53224 USA • Phone (414) 973-3400 • Fax (414) 973-3210 • www.phx-international.com • info@phx-international.com...
  • Page 7 For overseas operation we suggest a minimum of 30% more for spares. Phoenix International, Inc. warrants its products against defects in material and This warranty applies only to Products sold by Phoenix International, Inc. and workmanship. The company will, at its discretion, repair or replace any prop-...

This manual is also suitable for:

Dryrod 15Dryrod 14Dryrod 9Dryrod 7Dryrod 11Dryrod 10 ... Show all

Table of Contents