Download Print this page

Mounting Dimensions; Ordering Information - Robertshaw 5500-103M Installation Data

Infinite switch kit

Advertisement

WIRING ROBERTSHAW VSI TO ROBERTSHAW 5500 M SERIES
Connect wires from old switch to new switch as follows:
WIRING EGO TO ROBERTSHAW
Old (EGO) Switch
Pilot
4
2
SLIP-FIT® DIAL ASSEMBLY
NOTE: IT IS ESSENTIAL TO READ EACH STEP COMPLETELY BEFORE
PERFORMING THE DIRECTIONS GIVEN IN THAT STEP.
1. Turn control to the "Off" position.
2. Locate the 4-way insert included with this dial kit.
Push the 4-way insert flush onto the tip of the dial shaft of the control.
3. Referring to the other control knobs on the appliance, determine
which way the new knob is to be oriented in the "Off" position; vertical
or horizontal.
4. Using the vertical or horizontal orientation desired, partially
assemble the knob onto the insert to obtain proper alignment.
Then remove the knob with the insert attached, and press the insert all

MOUNTING DIMENSIONS

1.77
0.886
1.50
0.614
0.75
(4X) 8-32 MOUNTING NUTS
1.10
MAX DISTANCE

ORDERING INFORMATION

5500M Series
UNI-LINE PART #
5500-103M
5500-104M
5500-113M
5500-203M
5500-204M
5500-208M
5500-213M
5500-134M
5500-135M
5500-234M
5500-235M
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
HVACCustomerService@robertshaw.com
VSI Switch
Terminal #
L1
connect to
L2
connect to
P
connect to
H1
connect to
H2
connect to
Terminal #
P1
connect to
P2
connect to
Pilot
connect to
4
connect to
2
connect to
0.886
0.75
FACTORY #
MPA-V112-1-UXM
MPA-V112-1-UXM
MPA-V113-1-UXM
MPA-V116-UXM
MPA-V116-UXM
MPA-V115-2-UXM
MPA-V117-UXM
MPA-V114-1-UNM
MPA-V114-1-UNM
MPA-V119-UNM
MPA-V119-UNM
For Technical Service
Telephone 1.800.445.8299
TechnicalService@robertshaw.com
5500M (MPA) Switch
Terminal #
L1
(H1)
L2
P
H1
(HC)
HC
5500 M (MPA) Switch
Terminal #
L2
(H1)
L1
P
H1
(HC)
HC
the way onto the knob. When completely in place, approximately 1/8" of
the 4-way insert will be outside of the knob. Reinstall knob.
5. Take the Slip-Fit overlay, and carefully remove the clear protective
covering over the numbered side. Begin removal from the inside edge
of the overlay.
6. Carefully peel off the backing from the adhesive that is on the back
of the Slip-Fit overlay. Try not to touch the adhesive.
7. Position the Slip-Fit dial overlay over the knob with the "Off"
position aligned in the desired position. Carefully slide the
Slip-Fit overlay down and over, locating the ribs on the knob.
8. Press the Slip-Fit overlay firmly into position. Use a soft cloth and
rub around the overlay to obtain a permanent fit.
WIRING SCHEMATIC
Replaces
UNI-LINE PART #
5500-103
5500-104
5500-113
5500-203
5500-204
5500-208
5500-213
5500-134
5500-135
5500-234
5500-235
Robertshaw®, Ranco®, Paragon® and Uni-Line® are trademarks of
Robertshaw, its subsidiaries and/or affiliated companies. All other
brands mentioned may be the trademarks of their respective owners.
(L1)
(L2)
(P)
(L1)
(L2)
(P)
WARNING: The rear housing has a ¼"
diameter hole which is an access point to
be used ONLY by qualified personnel for
insuring proper assembly and calibra-
tion of the switch. Any tampering with
internal components or altering factory
settings of this switch will possibly dam-
age other electrical components on the
appliance and will immediately VOID the
WARRANTY of the switch.
FACTORY #
VOLTAGE
INF-120-599
120V AC
INF-120-599
120V AC
INF-120-599B
120V AC
INF-240-597
240V AC
INF-240-597
240V AC
INF-208-642
208V AC
INF-240-597B
240V AC
INF-120-1152
120V AC
INF-120-1152
120V AC
INF-240-1153
240V AC
INF-240-1153
240V AC
MODEL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
COMMERCIAL
COMMERCIAL
COMMERCIAL
COMMERCIAL
www.robertshaw.com
©2016 Robertshaw
07/16 –354-00028-003 RevB