TABLE OF CONTENTS INTRODUCTION GETTING STARTED SAFETY INSTRUCTIONS SYSTEM OVERVIEW INSTALLATION Preparing the Pool Water Installing the Electrolytic Cell & Flow Switch Installing the Control Module Wiring Adding Salt Installation Checklist OPERATION How it Works Initial Start Up General Operation Using the Control Module MAINTENANCE General Maintenance...
Electronic Chlorine Generator. CircuPool’s high performance systems offer escape from the routine of manual pool chlorination and sanitization. The RJ PLUS Series uses a low level of salt in the pool water to continuously create free chlorine, killing bacteria and algae in the water and helping to maintain a sparkling clean pool.
WARNING: Follow all aspects of local and National Electrical Code(s) when installing the CircuPool RJ PLUS Series. Disconnect all AC power during installation & service. WARNING: To reduce the risk of injury, do not permit children to operate this device.
Page 5
10 times the maximum number of daily spa users. Refill spa with water and repeat initial startup instructions on page 13 of this manual. Ensure that the RJ PLUS Series installation does not constitute a cross connection with the local potable water supply. Consult local plumbing codes. ...
SYSTEM OVERVIEW There are three main components to your CircuPool RJ PLUS Series system: the Control Module, the Electrolytic Cell, and the Flow Switch. Control Module: This component supplies power to the cell and allows you customize the system's operation, in order to meet your pool's unique needs.
INSTALLATION Preparing the Pool Water It is important that the pool's water chemistry is balanced before the RJ PLUS Series is powered on and used. When adding salt to the pool water, see "Adding Salt" on page 10. For important information about other water chemistry levels, see "Ideal Chemistry Levels"...
Page 8
Vertical Installation Kits are also available to minimize plumbing space required and increase ease of installation (sold separately, available at www.circupool.com). TIP: Double-check that all Cell and Flow Switch cables can reach the Control Panel.
3. Hold the Cell and second Union up to the first, to gauge the correct distance before gluing the second Union to the remaining pipe end. Allow sufficient time for glue to dry. Ensure that the O-rings are fitted to the Unions. Place the Electrolytic Cell between the Unions and tighten the Collars onto the Cell.
Page 10
CircuPool RJ-Series has been designed to easily wire into typical in- ground pool systems. To provide safe operation, the unit must be properly grounded and bonded. Bonding: A lug used for bonding is attached to the bottom of the Series Control Module.
Page 11
Always double-check the voltage of your power source. Connection to improper voltage can: a) cause severe damage/harm, or b) cause lights and screen to power on without system function. In some parts of the United States and Canada, the Control Module must be connected to a circuit protected by a Class A ground fault interrupter (GFI).
(the RJ PLUS Series is to remain off during this time period). Do not throw the salt bag into the water as chemicals and inks on the bag can interfere with water balance.
Page 13
Calculating Gallons (Measurements in Feet) Rectangular - Length x Width x Average Depth x 7.5 Round - Diameter x Diameter x Average Depth x 5.9 Oval - Length x Width x Average Depth x 6.7 Before adding salt, check your water for any existing salt content and add according to the chart below.
OPERATION How it works The RJ PLUS Series chlorine generator, by electrolysis, creates chlorine to sanitize your pool from the salt molecules (NaCL) in your water. A small electric charge is applied across a set of titanium plates inside the Electrolytic Cell.
Once determined, it should only take minor adjustments throughout the season. General Operation By familiarizing yourself with the operation of the RJ PLUS Series, you can achieve the maximum performance for your pool. There are typically three factors that you can control which directly contribute to...
running the pool pump longer allows for more chlorination. Measure your water chemistry and chlorine level on a regular basis. Using the Control Module CONTROL BUTTONS 1) Power: Use this button to manually power the system on or off. 2) Chlorine Output: Use the plus/minus buttons to raise/lower the system's power setting (the rate of chlorine production), in order to customize operation for your pool's needs.
Page 17
5) Winter Mode: Reduces the chosen Chlorine Output setting by half, for periods of low chlorine demand during cool weather. 6) Select: While in the Menu, the left/right arrows change options for Pool Temperature, Instant Salinity, and Cell Version. 7) Menu: Press sequentially to cycle through the following information: 1.
Page 18
• Salinity: Located on the Salinity button, this LED is illuminated when the button has been pressed to display the salt level reading. • Remote: The part is controlled by a remote control system. • No Flow: This LED is illuminated when the Flow Switch has detected no flow.
General Maintenance To maintain maximum performance, it is recommended that you remove and visually inspect the cell at least every 3-4 months. The RJ PLUS Series will illuminate the “Check Cell” LED when cleaning is absolutely necessary. The frequency of cleaning depends on your water chemistry and the Saturation Index of the water.
Page 20
CHEMISTRY TIPS: Chlorine Stabilizer (Cyanuric Acid) Stabilizer is needed to maintain proper levels of chlorine; the sun’s UV radiation can destroy unstabilized chlorine in as quickly as 2 hours. Stabilizer should be maintained between 50-75 ppm. Nitrates and Phosphates These chemicals can cause extremely high chlorine demands and will deplete chlorine from your pool.
"Check Cell" light when such cleaning is necessary. With correct water chemistry, the Cell will typically only need cleaning once or twice a season. Visit www.circupool.com/help for more information. When removing the Cell for cleaning or replacement: 1) Turn off all power, close return line valves if applicable.
Page 22
Winterizing Very little chlorine is necessary at low temperatures. The RJ PLUS Series will not produce chlorine at very cold temperatures, especially below 60° F. This feature extends the lifespan of the Cell. The Electrolytic Cell will be damaged by freezing water just as your pool plumbing would.
All service should only be attempted by a person with appropriate electrical skills, with all equipment disconnected from power. The RJ PLUS Series is shipped from the factory with a 240 VAC configuration unless specially ordered. If 120VAC is needed, move the internal jumpers as shown below.
Proper operation of the chlorine generator can be easily verified by checking the lights on the control panel. However, if the pool remains cloudy, or the chlorine residual tests low, then the chlorine being produced is being lost due to high chlorine demand or improper water...
Page 25
Definitions: Algae Plant-like organisms which grow in water. Especially active in summer conditions, where chlorine disinfectant level is too low to destroy them. Algae may be green, brown, or black (Black Spot) in color. Chlorine Demand The amount of chlorine that should be added to the water to provide proper bacteria and algae control.
TROUBLESHOOTING SCENARIO: POSSIBLE CAUSE: SUGGESTED ACTION: Low or no chlorine Insufficient Chlorine Increase Output Level. This is Output Level often required seasonally with residual in pool increasing temperatures. Insufficient run time Increase run time to at least 1 hour per 10° ambient temp. Heavy pool use, inclement Activate Super CL mode or weather, organic matter...
Page 27
For more information on troubleshooting, visit www.circupool.com/help. Salinity is out of range Verify salinity (see page 10). Lo Salt LED is on / Hi Salt LED is on Loose cell connection, Ensure correct connection, Cell is dirty or clogged clean Cell if necessary.
Upon examination, the determination of the cause of failure shall be made solely by CircuPool Products. The date upon which the claim is submitted and an RMA is issued shall solely serve to determine at what point the claim falls within the schedule of warranty proration, in comparison with the original purchase date.
Page 29
G. Damage due to over-tightening of threaded components or excessive pressure or stress. The liability of CircuPool Products shall not exceed the repair or replacement of defective items or parts under the referenced limited warranty terms. There are no implied warranties of merchantability or fitness for a particular purpose that apply to this equipment.
Need help?
Do you have a question about the RJ PLUS series and is the answer not in the manual?
Questions and answers