Sherwood ENVIROFIRE EF-3 BAYi Owner Technical Manual
Sherwood ENVIROFIRE EF-3 BAYi Owner Technical Manual

Sherwood ENVIROFIRE EF-3 BAYi Owner Technical Manual

Sherwood stove user manual

Advertisement

ENVIROFIRE
PELLET STOVE
EF-3 BAYi
OWNERS TECHNICAL MANUAL
MODELS FS, FPI and BIH
SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD ROAD
VICTORIA, BRITISH COLUMBIA
V8M-2A3
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENVIROFIRE EF-3 BAYi and is the answer not in the manual?

Questions and answers

Summary of Contents for Sherwood ENVIROFIRE EF-3 BAYi

  • Page 1 ENVIROFIRE PELLET STOVE EF-3 BAYi OWNERS TECHNICAL MANUAL MODELS FS, FPI and BIH SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M-2A3...
  • Page 2: Table Of Contents

    Deciding Where to Locate Your Pellet Appliance ... 12 Vent Termination Requirements ... 12 Removing Your New Stove From It’s Pallet... 13 Masonry Fireplace Insert Installation ... 14 Assembling the Face Plate for the FPI & BIH Models ... 15 Model BIH Recommended Framing ...
  • Page 3: Important Safety Data

    Since Sherwood Industries Ltd. has no control over the installation of your stove, we grant no warranty implied or stated for the installation or maintenance of your stove, therefore, Sherwood Industries Ltd. assumes no responsibility for any consequential damage.
  • Page 4: Pellet Quality

    WOOD PELLETS DIFFER, SO WILL THE PERFORMANCE AND HEAT OUTPUT OF THE PELLET STOVE. Since Sherwood Industries Ltd. has no control over the quality of pellets that you use, we assume no liability caused by the quality of wood pellets used.
  • Page 5: Warnings And Recommendations

    If the power goes out, the unit will stop running. When the power comes back on, the stove will not restart unless the exhaust temperature is still above 140°F (60 °C).
  • Page 6: How To Start Your Pellet Appliance

    The scale on the Dial A Fire knob represents a range, not exact at times. Wood pellets of differing quality may effect the performance of the stove. If the stove has trouble operating at the end of its range, turn the heat output knob back slightly.
  • Page 7: Slider/Damper

    SLIDER/DAMPER INSTALLATION /OPERATION INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. Remove the knob and outer nut from the knob. Push the rod through the hole in the slider.
  • Page 8: Areas For Routine Inspection

    To remove the burn pot and burn pot liner open the door using the door handle provided located on the left-hand side of the stove, swing the door open. Lift the liner from the burn pot, lift the burn pot from the firebox by gently lifting the front of the burn pot up first then sliding the assembly from the air intake tube and the igniter cartridge.
  • Page 9 POST SEASON CLEAN-UP Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove be cleaned and serviced as stated above. (See Section Areas of Routine Inspection)
  • Page 10: Electrical Component Functions

    Should the convection blower be set on low and dial-a-fire set on high, the convection blower will by- pass the fan controller and go to high. This will cool the stove until control is given back to the fan controller. To eliminate possible cycling of the convection blower turn up the fan speed proportionately to the dial-a-fire.
  • Page 11: Vacuum Switch

    140°F (60°C) N/O TEMPERATURE SENSOR (SHUT-DOWN SENSOR) This sensor (mounted on the exhaust blower housing) has two functions: Should the fire go out, this sensor will shut the stove off when the exhaust temperature drops below 140°F (60°C). When the auger is turned off via the dial-a-fire, the exhaust temperature will drop, when it goes below 140°F (60°C) the sensor will turn the stove off.
  • Page 12: Deciding Where To Locate Your Pellet Appliance

    If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond Sherwood Industries Ltd.'s control, we grant no guarantee against such incidents.
  • Page 13: Removing Your New Stove From It's Pallet

    REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet, open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the side panels. See PAGE 18 how to install the pedestal.
  • Page 14: Masonry Fireplace Insert Installation

    ENVIROFIRE model FS and install as a hearth mounted unit. Install a 3” (76 mm) flex pipe from the stove to the top of the chimney. (550 mm)
  • Page 15: Assembling The Face Plate For The Fpi & Bih Models

    Place the brass frame over the panel assembly. To access the rear of the stove after the panels are assembled remove side brass and remove the anchor screws from the corresponding side. Swing panel open. Installation is the reverse.
  • Page 16: Recommended Framing For Built In Heater

    RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3”...
  • Page 17: Freestanding Installation, Models Fs

    FREESTANDING INSTALLATION, MODELS FS CLEARANCES TO COMBUSTIBLES (FREESTANDING) - Side wall to unit - Back wall to unit - Corner to unit - Mantle (Hearth Mount) Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and front must be protected by a non combustible material.
  • Page 18 MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION Model FS comes with a pedestal that has to be attached prior to installation: Remove the pedestal from the box Remove the ENVIROFIRE heater form the box. Place the unit on its back, making sure not to damage the wiring.
  • Page 19: Horizontal Exhaust Through The Wall

    Place the stove 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set the unit on it. 5. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the center point on the wall, use a hole saw to cut a 7”...
  • Page 20: Through Wall Installation

    THROUGH WALL INSTALLATION 1”...
  • Page 21: Freestanding Inside Vertical Installation

    FREESTANDING INSIDE VERTICAL INSTALLATION Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. Place a non-combustible hearth pad where necessary. Place the unit on the hearth pad and space it in a manner so when the pellet vent is installed vertically, it will be 3”...
  • Page 22: Freestanding Outside Vertical Pipe Installation

    FREESTANDING OUTSIDE VERTICAL INSTALLATION To accomplish the above titled installation, follow steps 1 through 8 in the previous section and then finish it by performing the following. Install a tee with clean out on the outside of the house. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.
  • Page 23: Mobile Home Installation

    MOBILE HOME INSTALLATION Secure the heater to the floor using the two bolt holes supplied in the pedestal. CAUTION: THE STUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. Ensure the unit is electrically grounded to the chassis of your home (permanently). Do not install in a room people sleep in.
  • Page 24: Troubleshooting

    The stove will not start Make sure the stove is plugged in and the wall outlet is supplying power. Push the Start-up switch, if the stove fails to start, unplug the unit and open the hinged side panels (held tight with two screws).
  • Page 25 (93°C) temperature sensor and the timing control module against the wiring diagram in this manual. Check the condition of the vacuum hose (located on the left side of the stove). It should not be cracked or torn and should be installed on the top air inlet tube on the vacuum sensor.
  • Page 26 140°F (60°C) sensor. If the stove does not shut down within 15 minutes, test the switch. To test the switch, the stove must be cold. Pull the plug, then plug the stove back in. If the fails to start, Replace the switch.
  • Page 27: Wiring Diagram

    WIRING DIAGRAM...
  • Page 28: Warranty

    Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one year warranty is provided on all electrical components. purchaser. There is no warranty on the following parts: Glass window Fiberglass rope baskets Refractory material...

This manual is also suitable for:

Envirofire fsEnvirofire fpiEnvirofire bih

Table of Contents