Summary of Contents for Dynamic SpeedCop 2000

  • Page 1 User Manual User Manual Wireless Home Security FM Wireless Home Security Alarm System Alarm System SpeedCop 2000- - SpeedCop 2000- Dynamic Technology Inc. www.dynamictek.com...
  • Page 2 Attention & Request Guide of emergency meeting Remote Controller Power & Tel.Line cut off Sensors Sensor Feature Telephone Number PIR Sensor & Remote Controller Emergency Call RF Transmitter & Door Sensor WARNING Notice: Please Read Carefully Password Dynamic Technology Inc.
  • Page 3: Standard Scope Of Supply

    T - Hanger Sticking an invasion route for warning Warning Decals Battery Supply ; the power to PIR sensor & RF transmitter Connector between the main body and local telephone Phone cable Utility Guide for SpeedCop2000 User Manual Dynamic Technology Inc.
  • Page 4 Alarm Contact : DC 24V, 50mA Alarm Contacts : DC 24V, 50mA Base - ABS Pulse Count : Selectable 1~3 Temper Contacts : DC 24V, 0.1A Dimensions : 26mm x 167mm x 96mm RF Immunity : 3-V/m. up to 1GHz Dynamic Technology Inc.
  • Page 5: Main Body(Front)

    In this case, user may be confused that each sensor does not operate as the back light of LCD can not operate. But, sensors are normally operated due to save the battery. * You must use DC 9V alkaline battery as a backup battery * Max. time : 6 hours Dynamic Technology Inc.
  • Page 6 Key : Cancellation Key 13. Ambulance : Emergency calling function to memorized hospital by one-touch button 14. Cover Open/Close : SpeedCop 2000 cover open/close 15. Police : Emergency calling function to memorized police station by one-touch button Key : Enter Key 17.
  • Page 7 4. Infrared Detector : Installing both sides of intruding route and detector sensing when intruder passes through this route 5. Fire Detector : Detecting fire and smoke 6. Gas Detector & Shut-off Device : Gas shut off equipment with remote controller from outside Dynamic Technology Inc.
  • Page 8 12. Input B : The second input terminal for transmission of signal from sensors to main body 13. GND : DC 9V power ground terminal 14. DC power terminal : DC 9Vpower terminal 15. DC power terminal : DC 9Vpower terminal(for Adapter) Dynamic Technology Inc.
  • Page 9: Operating Flow

    Tapping and checking by sounds from the outside Emergency Call Emergency Call PSTN : Local Telephone Controlling of the intruder with Siren and arms(Option) Memorized 7 C/Phone Phone No. Related Neighbors Call to related office or neighbor for help. Office Company Dynamic Technology Inc.
  • Page 10: Order Of Installation

    7 . F i x i n g a n d h a n g i n g m a i n b o d y & e a c h s e n s o r s Installation Completed Installation Completed Dynamic Technology Inc.
  • Page 11: Power & Sensors

    C o n n e c t i n g o f S e n s o r s Siren Telephone line Output 1 Output Com Output 2 Input 1 Gas Parts Input Com Input 2 DC 12V controller Breaker Other wire sensors Picture 2 Dynamic Technology Inc.
  • Page 12 2. Please install PIR sensor after setting up sensors. D o o r S e n s o r D o o r S e n s o r Magnetic Bar RF Transmitter Within 1Cm 1. Not more than 1Cm between the two magnetic bars Dynamic Technology Inc.
  • Page 13 If you want to cancel inputting information while you input, please enter asterisk key Use reset for deletion purpose only Keypad (Liquid Crystal Display) SpeedCop 2000 Resetting of the first remote controller Menu Input : Press the number Press the number...
  • Page 14: Remote Controller

    Emergency Call 41 ~ 43 Exit (*Siren On/Off : 81) Keypad (Liquid Crystal Display) Input the first Remote controller SpeedCop 2000 Menu Input : Press the number Press the number again Menu Input : 11 (The second remote controller is number...
  • Page 15 Input - SpeedCop 2000 Sensors Keypad (Liquid Crystal Display) Input of the first sensor SpeedCop 2000 Menu Input : Press the number Press the number Menu Input : 21 (The second sensor No. : Sensor Setup #1 Press the Put the battery into a sensor or sensing...
  • Page 16: Lcd Display

    Input - SpeedCop 2000 Telephone Number Keypad LCD Display SpeedCop 2000 Input the first Telephone number Menu Input : Press the number Press the number Menu Input : 31 - The second telephone number : Tel. Number : Press the...
  • Page 17 Input - SpeedCop 2000 Emergency Call Keypad (Liquid Crystal Display) Input the first emergency call number SpeedCop 2000 Menu Input : Press the number Menu Input : 41 Press the number Emergency Tel Press the Please input the first emergency call number(ex : 911)
  • Page 18 Input - SpeedCop 2000 Password Keypad (Liquid Crystal Display) Input of Password SpeedCop 2000 Menu Input : Press the number Menu Input : Press the number Password : Press the number Password : 1234 Please input 4 digit password Input Completed...
  • Page 19 Input - SpeedCop 2000 Voice Recording Keypad (Liquid Crystal Display) Voice Recording SpeedCop 2000 Menu Input : Press the number Menu Input : 61 Press the number Recording : Press the The main body will start recording warning message for 12 seconds...
  • Page 20 Input – SpeedCop 2000 Delay Time Keypad (Liquid Crystal Display) Input Exit time SpeedCop 2000 Menu Input : Press the number Menu Input : Press the number Delay Time : Press Delay Time : Input the interval time you wanted (ex : 15 seconds)
  • Page 21 Input - SpeedCop 2000 Siren On/Off Keypad LCD Display Siren ON/OFF SpeedCop 2000 Menu Input : Press the number Menu Input : Press the number Siren : Press the Please press any number key( Siren : The main body is changed from on(off) to off(on) automatically.
  • Page 22 Number + Telephone No.3 + Input completed Input of + Enter password Input completed (****) Password + Recording Recording time indicated Voice 12 seconds Recording + Reply Reply indicated + (0~99 seconds) + Input completed Stay Dynamic Technology Inc.
  • Page 23: Arming And Disarming

    2000 Arming Disarming Arming Disarming All sensors armed Converting from Arming to disarming mode Arming Completed Disarming Completed Time Out : Only power LED is On in standby mode Green LED is flicker Arm Power Aem Power Dynamic Technology Inc.
  • Page 24 * Suitable Exit time : 10 ~ 15 seconds Sensor 1 and 3,5,7 Arm led is flicker are armed Arm Power Bypass Function Bypass Function Bypass : User select specific sensor and then register at the main body, so the specified sensors are armed. Dynamic Technology Inc.
  • Page 25: Special Function

    Chime Function Chime Function 1.You can confirm if a door or window is open / close in a zone when you are out. 2.You can use chime bell function by push the Chime button when disarming mode. Dynamic Technology Inc.
  • Page 26: Remote Control

    Calling code number is “50”, arming number is “10” disarming number is “20” to end press “star”key To listen again press “0” To listen again press “0” To listen again press “0” To listen again press “0” Order performance Order performance Dynamic Technology Inc.
  • Page 27 B ( E x : G a s c o n t r o l l e r , O u t d o o r s i r e n e t c . ) Dynamic Technology Inc.
  • Page 28 Checking gas siren (50) G a s Turn off the gas panel for rechecking Turn off the Gas(70) S e n s i n g Input the remote control code for arms and then Emergency Completion(*) emergency is completed Dynamic Technology Inc.
  • Page 29 1 . B a t t e r y o f m a i n b o d y Enter button Main Low Bat Please change battery 2 . B a t t e r y o f S e n s o r Enter Button Low Bat Sensor #3 Please change battery Dynamic Technology Inc.
  • Page 30 • Arming & Disarming function • Stay : Press the Arming & Disarming button at the same time • Emergency Call : Press arming button for 3 seconds at least • Automatic notice of low voltage • Communication distance : about.50M Dynamic Technology Inc.
  • Page 31: Door Sensor

    Gas Sensor Intruder detected Fire detected Gas detected Door Sensor Door Sensor • When sensor is operating magnetic bars on doors / windows come off • Use together with RF transmitter • Magnetic bar operates a magnet principle Dynamic Technology Inc.
  • Page 32 WARNING SpeedCop 2000 Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible.
  • Page 33 WARNING SpeedCop 2000 Please Read Carefully System Users A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm.